Bradford-White Corp MITW -12 / -15, MITW -10 manual Mitw -12 / -15 Series

Page 13

TTW1 Universal Service

Replacement Blower

MITW -12 / -15 Series

Step 4. Remove the screws, qty. (3), that secure the blower to the jacket head.

Unscrew (3) screws that hold

blower to the jacket head.

Blower junction box

Step 5. Disconnect blower wire harness from receptacle, located in the jacket head under the blower junction box. The white connector must be pinched to remove.

Unplug blower harness from jacket head receptacle by pinching the connector.

Step 6.

Remove the blower from the top of the

 

water heater. Remove any loose debris

 

and tools from the top of the water heater.

 

 

Warning:

Failure to locate the blower correctly will

 

 

result in improper water heater operation.

 

 

 

 

Step 7.

Create the new mounting hole locations

 

for the new universal replacement blower.

 

Use template supplied with manual.

 

a.) On the template, P/N 238-47197-00,

 

the (3) circular sections for the water

 

connections and flue have already

 

been removed. Also, the dotted lines

 

from the side of the paper are

 

perforated for easy tearing.

The (3) circular sections on template have been pre-cut and removed.

Tear paper along dotted lines where perforation exists, or cut with scissors.

Page 13

Image 13
Contents Instructions for Model Numbers Reference Kit Components Tools Required Bradford White TTW1 Universal Service Replacement Blower Step Remove the screws, qty , that secure Inside the access compartment, follow Just below the crimp connector, cut Plug both the blower Check all safety devices to make sure they Unplug the water heater from wall outlet Mitw -12 / -15 Series Place template on top of water heater in correct orientation TTW1 Universal Service Replacement Blower Secure Cover Screws Blower screws TTW1 Universal Service Replacement Blower Do not over tighten 2 screws attaching Tighten 2 screws on junction Box to secure cover Operation could occur if these devices are not M1TW60T*FCX TTW1 Universal Service Replacement Blower TTW1 Universal Service Replacement Blower Secure Cover screws Boot back Place Secure 3 blower screws Step If the new adapter is used, remove the old