Bradford-White Corp MITW -12 / -15, MITW -10 Tighten 2 screws on junction Box to secure cover

Page 19

TTW1 Universal Service

Replacement Blower

MITW -12 / -15 Series

Step 17. Secure the junction box cover, P/N

239-47199-00, to the junction box.

Tighten (2) screws on junction

box to secure cover.

Step 18. With the blower and transformer assembly

fastened to the water heater, the

remaining ends of the blower wire harness can now be attached with the cord sets to the blower and then the white connector to the receptacle in the jacket head.

Plug cord sets into receptacles in blower.

Plug white connector into receptacle in jacket head.

Be sure that vent pipe is properly seated in the top side of vent adapter.

Step 19. Find the rubber vent adapter kit, P/N

239-46263-00, provided with the blower

kit. Install the 2” vent adapter on the exhaust side of the universal blower.

Discard the vent terminal included with

the vent adapter kit.

Note: In order to prevent condensate from draining back into the blower (vertical or horizontal runs), an optional condensate kit is available as a service part (Condensate kit, P/N 239-45875-00).

Rubber vent adapter Adequately tighten both

clamps on the vent adapter.

Page 19

Image 19
Contents Instructions for Model Numbers Reference Kit Components Tools Required Bradford White TTW1 Universal Service Replacement Blower Step Remove the screws, qty , that secure Inside the access compartment, follow Just below the crimp connector, cut Plug both the blower Check all safety devices to make sure they Unplug the water heater from wall outlet Mitw -12 / -15 Series Place template on top of water heater in correct orientation TTW1 Universal Service Replacement Blower Secure Cover Screws Blower screws TTW1 Universal Service Replacement Blower Do not over tighten 2 screws attaching Tighten 2 screws on junction Box to secure cover Operation could occur if these devices are not M1TW60T*FCX TTW1 Universal Service Replacement Blower TTW1 Universal Service Replacement Blower Secure Cover screws Boot back Place Secure 3 blower screws Step If the new adapter is used, remove the old