TTW1 Universal Service
Replacement Blower
MITW
Warning: | Failure to install flue restrictor will result in |
|
| improper water heater operation. |
|
|
|
|
Step 7. | Install the flue restrictor, P/N | |
| ||
| be necessary to lightly tap down the flue | |
| restrictor. Be sure to tap it evenly and | |
| straight down. Wire brush the top of the | |
| water heater if rust or corrosion exists. | |
|
| |
Warning: | Do NOT remove Torx head screws from |
|
| universal blower. |
|
|
|
|
Step 8. | Instructions to remove power cord from | |
| new universal blower: | |
| a.) Unscrew the (3) Philips head screws | |
| on the blower access cover and | |
| remove the cover. Keep the cover and | |
| screws for future use. | |
| Blower access cover | |
| (covers access compartment) | |
| Power inlet | |
| connector | |
| b.) Inside the access compartment, follow | |
| the black wire from the power cord until | |
| you reach the flag terminal attached to | |
| the end of the wire. Disconnect black | |
| wire from the back of the power inlet | |
| connector. | |
| Power inlet | |
| connector | |
| Power cord |
Place flue
restrictor on flue.
Loosen all (3) screws
holding cover on.
Black wire
Remove black
wire’s flag terminal
Page 8