RIDGID K-2000 manual Starting Engine/Generator, Operating Machine Using Cables

Page 8

K-2000 Municipal Sewer Cleaning Machine

Manhole

Guide Pipe

Rear Guide

 

Hose

Turnbuckle

Figure 5 – Cable Operation

Starting Engine/Generator

CAUTION

Make sure engine crankcase is filled to indicated level with SAE-30 Oil.

1.Fill tank with regular gasoline.

2.Open gas shut-off valve.

3.Position FOR/OFF/REV SWITCH in OFF position.

4.Put ON/OFF SWITCH to ON position and close choke.

5.Pull starter rope. Engine should be running after two or three pulls.

6.Open choke when engine catches. Warm up engine for three minutes.

NOTE! For any reason engine does not start, refer to power plant instruction manual in tool box.

Operating Machine Using Cables

1.Place FOR/OFF/REV SWITCH (Figure 3) in FOR position.

2.Push on clutch handle maintaining firm pressure while feeding cable.

3.If tool meets heavy obstruction, release clutch handle, and place switch handle in OFF position.

4.When cable rotation stops, place switch handle in REV position and push firmly on clutch handle to back out and release tool.

5.When tool is free, place switch handle in OFF then FOR position to advance cable.

NOTE! Heavy and stubborn obstructions will require sev- eral repetitions of this procedure.

6.Release clutch handle and connect additional cables from rear as required.

7.As additional cables are added, keep count by ad- vancing manual cable counter.

 

Clutch

Propulsion

Spring

 

Handle

Clutch Handle

FOR/OFF/REV

Loaded Pin

 

 

Switch

 

Rod Driver

 

 

 

 

 

 

Nose Cone

Latch

Control Panel

 

 

 

 

 

 

 

 

Guard

 

 

 

Rod Driver

 

 

 

Assembly

Fuel

 

 

 

Tank

 

 

Motor Table

 

 

 

Engine/Generator

 

 

 

Pull Starter

Rear Wheel

Lock

Tool Box

Figure 6 – K-2000 Machine with Rod Driver Assembly and Clutch Handle in Remote Control Housing

6

Ridge Tool Company • Elyria, Ohio • U.S.A.

Image 8
Contents 2000Municipal Sewer Cleaning Machine Table of Contents 2000 General Safety Information Specific Safety InformationMachine Safety Description, Specifications and Standard Equipment Operating InstructionsPut machine guard back in place Operating Machine Using Cables Starting Engine/GeneratorOperating Machine Using Rods Removing Cable from PipelineStopping Engine/Generator Preparing Machine for Rod OperationMaintenance Instructions 230V/50 Hz Wiring Diagram115V/60 Hz Municipal Sewer Cleaning Machine Machine à curer les égouts Table des Matières Consignes de sécurité généralesConsignes de sécurité générales Sécurité du chantierSécurité personnelle Utilisation et entretien de la machineConsignes de sécurité particulières Sécurité de la machineDescription, spécifications et équipements standards SpécificationsAccessoires Instructions d’utilisationEquipements standards Préparation de la machine pour l’utilisa- tion des câbles10. Réglez le guide télescopique en fonction de Démarrage du moteur/générateur Utilisation de la machine avec câblesPréparation de la machine pour l’utilisa- tion des tringles Retrait du câble de la canalisationArrêt du moteur/générateur Utilisation de la machine avec tringles Mise EN GardeEntretien Schéma électrique Máquina para la Limpieza de Desagües Municipales Índice Información General de SeguridadInformación General de Seguridad Seguridad de la Zona de TrabajoSeguridad Personal Uso y Cuidado de la HerramientaInformación Específica de Seguridad Seguridad de la MáquinaEspecificaciones Descripción, Especificaciones y Equipo EstándarDescripción Instrucciones para el Funcionamiento Equipo EstándarPreparación de la Máquina para su Funcionamiento con Cable AccesoriosRegule el tubo guía telescópico para la boca de Arranque del Motor/Generador El Funcionamiento de la Máquina Usando CablesPreparación de la Máquina para el Funcionamiento con Cable Extracción del Cable de la TuberíaDetener el Motor/Generador Funcionamiento de la Máquina Usando Varillas AdvertenciaInstrucciones para el Mantenimiento Diagrama de Cableado 2000 Máquina para la Limpieza de Desagües Municipales 2000 Máquina para la Limpieza de Desagües Municipales Lifetime Warranty