GE 268, 263 manual Programming Overview, Level I Programming, Setting Time of Day

Page 26

Programming Overview

The Ultramax Series controller is designed to operate by setting the Time of Day, Day of the Week, and the Hardness. The remaining settings are set at the factory using a Model Number.

The controller menu has three levels:

Level I Basic — This level is easily accessed by the user. Only the Time of Day, Day of Week and Time of Regeneration can be changed in Level I.

Level II Professional — This level allows the installer to change settings such as hardness, capacity, and cycle times.

Level III History — This operation history and the program are viewable. This information is used to troubleshoot and maintain the system.

NOTE: If a button is not pushed for thirty seconds, the controller returns to normal operation mode.

NOTE: Any setting that is a time display will not show "AM" for times between 12:00 midnight and 12:00 noon. "PM" is displayed to the right of the time for times between 12:00 noon and 12:00 midnight. When using the 24 hour clock "PM" is not displayed.

Level I Programming

Level I program parameters are those that can be accessed by the end user by pressing the SET button. They include:

Time of Day

Day of Week

Time of Regeneration

Setting Time of Day

Upon initial start up of the controller, you will need to set the time of day. The words “Time of Day” will scroll across the banner display and the currently programmed time of day will be flashing below. If time is not flashing, press the SET button. To change the time of day, press and hold the UP or DOWN button until the correct time of day is displayed. Press the SET button to accept the selection.

NOTE: When the controller is set up for a twelve hour clock a PM indicator will illuminate when the displayed time is in the PM hours. There is no AM indicator

26

Programming Overview

Rev A

 

Image 26
Contents Operations Manual Table of Contents How To Use This Manual Icons That Appear In This Manual IntroductionMechanical General Warnings And Safety InformationElectrical General System Operation Cycle Functions Cycle Water Flows Equipment Installation Valve Layout Control Layout Ultramax ControllerLocation Selection Outdoor LocationsLocation Selection Rev a Water Line Connection Water Line Connection Rev a Drain Line Drain Line ConnectionRegenerant Line Connection Not used with 3-cycle filter systemOverflow Line Connection Overflow Line Connection Rev a Controller Location Electrical ConnectionVAC AC Adapters AC Adapter Input Application Part NumberValve Camshaft Sodium or Calcium Hypochlorite Application Disinfection Of Water ConditionersValve Disc Operation 25% Sodium HypochloriteCalcium Hypochlorite Motor Power Loss Memory RetentionUltramax Controller Controller MemoryDisplay Icons Keypad Buttons Programming ConventionsThings You Might Need to Know Level I Programming Setting Time of DayProgramming Overview Setting Day of Week Setting Regeneration TimeConditioner Operation Type Setting the Calendar OverrideLevel II Programming Filter Operation TypeSetting Capacity Softener Default Capacity Setting Setting Backwash Days 263 filter onlySetting the Salt Amount 268 softener only Setting the Hardness conditioner onlyAdjusting the Cycle Times Conditioner Cycle Times Setting Clock ModeSetting Units of Measure Viewing the Injector TypeSetting the Service Interval Operation TypeSetting the Chlorine Generator/Salt Check conditioner only Peak Flow Rate GPMa Months Since SERVICEaLevel III Programming Total Water Used GAL X 100aFunction Display Text Placing Conditioner Into OperationConditioner and Filter Start-Up Action Key Duration Display SETRev a Performa Exploded View Performa Parts List Part Code Description QtyProblem Possible Cause Solution TroubleshootingUltramax Series Controller Troubleshooting System Troubleshooting Intermittent or Low water pressure Rev a UltraMax System Configurations Controller Reset