The controller is capable of displaying 6 different languages. They are as follows:

1 = English

2 = Spanish

3 = French

4 = Italian

5 = Flemish

6 = German

Press the SET button and select the desired language using the UP or DOWN buttons. Press the SET button to accept the selection.

Setting Clock Mode

The controller can be programmed to operate with a 12- or 24-hour clock. Program the clock mode to "12" for a 12-hour clock or "24" for a 24-hour clock. When the controller is programmed as a 12-hour clock the PM indicator will illuminate during the PM hours. There is no AM indicator.

Setting Units of Measure

The controller can be programmed to operate in U.S. or Metric units. Program the Units of Measure to 0 (zero) for U.S. units or 1 for Metric units.

Viewing the Injector Type

Is selected by system model number and cannot be changed.

Adjusting the Cycle Times

Conditioner Cycle Times

The following cycle times are adjustable.

268 Conditioner

 

Cycle

Range

Backwash 1

1-60 minutes

Slow Rinse *

1-125 minutes

Fast Rinse 1

1-30 minutes

Backwash 2

0-30 minutes

Fast Rinse 2

0-30 minutes

263 Filter Cycle Times

 

Cycle

Range

Backwash

1-50 minutes

Fast Rinse

1-30 minutes

Refill time does not appear as this cycle time is determined by the salt setting.

*The controller calculates the Slow Rinse default time on injector type, system size and salt dosage. The cycle times can be adjusted for custom applications. Please contact your Ultramax Water Treatment Dealer before attempting to adjust the Slow Rinse time.

30

Level II Programming

Rev A

 

Image 30
Contents Operations Manual Table of Contents How To Use This Manual Icons That Appear In This Manual IntroductionGeneral Warnings And Safety Information ElectricalMechanical General System Operation Cycle Functions Cycle Water Flows Equipment Installation Valve Layout Control Layout Ultramax ControllerLocation Selection Outdoor LocationsLocation Selection Rev a Water Line Connection Water Line Connection Rev a Drain Line Drain Line ConnectionRegenerant Line Connection Not used with 3-cycle filter systemOverflow Line Connection Overflow Line Connection Rev a Controller Location Electrical ConnectionVAC AC Adapters AC Adapter Input Application Part NumberValve Camshaft Sodium or Calcium Hypochlorite Application Disinfection Of Water ConditionersValve Disc Operation 25% Sodium HypochloriteCalcium Hypochlorite Motor Power Loss Memory RetentionUltramax Controller Controller MemoryDisplay Icons Keypad Buttons Programming ConventionsThings You Might Need to Know Setting Time of Day Programming OverviewLevel I Programming Setting Day of Week Setting Regeneration TimeConditioner Operation Type Setting the Calendar OverrideLevel II Programming Filter Operation TypeSetting Capacity Softener Default Capacity Setting Setting Backwash Days 263 filter onlySetting the Salt Amount 268 softener only Setting the Hardness conditioner onlyAdjusting the Cycle Times Conditioner Cycle Times Setting Clock ModeSetting Units of Measure Viewing the Injector TypeSetting the Service Interval Operation TypeSetting the Chlorine Generator/Salt Check conditioner only Peak Flow Rate GPMa Months Since SERVICEaLevel III Programming Total Water Used GAL X 100aPlacing Conditioner Into Operation Conditioner and Filter Start-UpFunction Display Text Action Key Duration Display SETRev a Performa Exploded View Performa Parts List Part Code Description QtyTroubleshooting Ultramax Series Controller TroubleshootingProblem Possible Cause Solution System Troubleshooting Intermittent or Low water pressure Rev a UltraMax System Configurations Controller Reset