WARNING: If opened too rapidly or too far, media may be lost out of the tank into the valve or the plumbing. In the ¼ open position, you should hear air slowly escaping from the valve drain line.

B.When all of the air has been purged from the media tank (water begins to flow steadily from the drain line), open the main supply valve all of the way. This will purge the final air from the tank.

C.Allow water to run to drain until the water runs clear from the drain line. This purges any refuse from the media bed.

D.Turn off the water supply and let the system stand for about five minutes. This will allow any air trapped to escape from the tank.

NOTE: 263 Filter - advance control back to the treated water position, proceed to Step 12.

8.Add water to the regenerant tank (initial fill) (conditioner only).

A.With a bucket or hose, add approximately 4 gallons (15 liters) of water to the regenerant tank.

If the tank has a salt platform in the bottom of the tank, add water until the water level is approximately 1 inch (25 mm) above the platform.

NOTE: We recommend that you do not put regenerant into the tank until after the control valve has been put into operation. With no regenerant in the tank, it is much easier to view water flow and motion in the tank.

Action

Key

Duration

Display

 

 

 

 

Display current

SET

5 Sec.

Current cycle

cycle

 

 

 

 

 

 

 

Advance to next

SET and UP

Press and

Next cycle

cycle

 

release

 

 

 

 

 

Cancel

SET and UP

5 Sec.

Regeneration

regeneration

 

 

canceled

 

 

 

 

Placing Conditioner Into Operation

35

 

Rev A

Image 35
Contents Operations Manual Table of Contents Icons That Appear In This Manual Introduction How To Use This ManualMechanical General Warnings And Safety InformationElectrical General System Operation Cycle Functions Cycle Water Flows Equipment Installation Valve Layout Ultramax Controller Control LayoutOutdoor Locations Location SelectionLocation Selection Rev a Water Line Connection Water Line Connection Rev a Drain Line Connection Drain LineNot used with 3-cycle filter system Regenerant Line ConnectionOverflow Line Connection Overflow Line Connection Rev a AC Adapter Input Application Part Number Electrical ConnectionVAC AC Adapters Controller LocationValve Camshaft 25% Sodium Hypochlorite Disinfection Of Water ConditionersValve Disc Operation Sodium or Calcium Hypochlorite ApplicationCalcium Hypochlorite Controller Memory Power Loss Memory RetentionUltramax Controller MotorDisplay Icons Programming Conventions Keypad ButtonsThings You Might Need to Know Level I Programming Setting Time of DayProgramming Overview Setting Regeneration Time Setting Day of WeekFilter Operation Type Setting the Calendar OverrideLevel II Programming Conditioner Operation TypeSetting the Hardness conditioner only Setting Backwash Days 263 filter onlySetting the Salt Amount 268 softener only Setting Capacity Softener Default Capacity SettingViewing the Injector Type Setting Clock ModeSetting Units of Measure Adjusting the Cycle Times Conditioner Cycle TimesOperation Type Setting the Service IntervalSetting the Chlorine Generator/Salt Check conditioner only Total Water Used GAL X 100a Months Since SERVICEaLevel III Programming Peak Flow Rate GPMaFunction Display Text Placing Conditioner Into OperationConditioner and Filter Start-Up SET Action Key Duration DisplayRev a Performa Exploded View Part Code Description Qty Performa Parts ListProblem Possible Cause Solution TroubleshootingUltramax Series Controller Troubleshooting System Troubleshooting Intermittent or Low water pressure Rev a Controller Reset UltraMax System Configurations