9. | Intermittent or | a. | Low water pressure. | a. | Set pump to maintain 20 psi at conditioner. |
| irregular | b. | Defective injector. | b. | Replace injector. (Contact dealer.) |
| regenerant draw. | ||||
|
|
|
|
| |
10. | No conditioned | a. | No regenerant in regenerant | a. | Add regenerant to regenerant tank. |
| water after |
| tank. |
|
|
| regeneration. | b. | Injector plugged. | b. | Clean injector and screen. |
|
| ||||
|
| c. | Air check valve closes | c. | Put control momentarily into brine/slow |
|
|
| prematurely. |
| rinse. Replace or repair air check if needed. |
|
|
|
|
| (Contact dealer.) |
|
|
|
|
|
|
11. | Backwashes or | a. | Incorrect drain controller used. | a. | Replace with correct size controller. (Contact |
| purges at |
|
|
| dealer.) |
| excessively low | b. | Foreign matter affecting valve | b. | Remove drain controller and clean ball and |
| or high rate. | ||||
|
| operation. |
| seat. | |
|
|
|
| ||
|
|
|
|
|
|
12. | No water flow | a. | Bypass valve in bypass. | a. | Shift bypass valve to |
| display when | b. | Meter probe disconnected or not | b. | Fully insert probe into meter housing. |
| water is flowing. |
| fully connected to meter |
|
|
|
|
| housing. |
|
|
|
| c. | Restricted meter turbine rotation | c. | Remove meter housing, free up turbine and |
|
|
| due to foreign material in meter. |
| flush with clean water. Turbine should spin |
|
|
|
|
| freely. If not, replace meter. (Contact dealer.) |
|
|
|
|
|
|
13. | Run out of | a. | Improper regeneration. | a. | Repeat regeneration, making certain that |
| conditioned |
|
|
| correct regenerant dosage is used. |
| water between | b. | Incorrect regenerant setting. | b. | Set P6 to proper level. See salt setting chart . |
| regenerations. | c. | Incorrect hardness or capacity | c. | Set to correct values. See Programming |
|
| ||||
|
|
| settings. |
| section. |
|
| d. | Water hardness has increased. | d. | Set hardness to new value. See |
|
|
|
|
| Programming section. |
|
| e. | Restricted meter turbine rotation | e. Remove meter housing, free up turbine and | |
|
|
| due to foreign material in meter. |
| flush with clean water. Turbine should spin |
|
|
|
|
| freely; if not, replace meter. (Contact dealer.) |
14. | Regenerant tank | a. | Regenerant valve disc 1 being | a. | Manually operate valve stem to flush away |
| overflow. |
| held open by foreign matter. |
| obstruction. |
|
| b. | Valve disc 2 not closed during | b. | Flush out foreign matter holding disc open |
|
|
| regenerant draw causing brine |
| by manually operating valve stem. |
|
|
| refill. |
|
|
|
| c. | Air leak in regenerant line to air | c. | Check all connections in regenerant line for |
|
|
| check. |
| leaks. Refer to instructions. |
|
| d. | Improper drain control for | d. | Too small of a drain control with a larger |
|
|
| injector. |
| injector will reduce draw rates. |
|
| e. | Drain control clogged with resin | e. | Clean drain control. |
|
|
| or other debris. |
|
|
|
|
|
|
|
|
Troubleshooting | 41 |
| Rev A |