9.Engage the refill cycle to prime the line between the regenerant tank and the valve (conditioner only).

A.Slowly open the main water supply valve again, to the fully open position. Be sure not to open too rapidly as that would push the media out of the media tank.

B.Advance the controller to the regenerant tank Refill position. From the Backwash 1 cycle, press and hold the SET button. This will display the current cycle.

NOTE: As you advance through each cycle there will be a slight delay before you can advance to the next cycle. There will be a pause after the brine draw and slow rinse cycles (system pause). This cycle allows the water/air pressure to equalize on each side of the valve discs before moving on.

C.With the water supply completely open, when you arrive at the regenerant tank refill cycle, the controller will direct water down through the line to the regenerant tank. Let the water flow through the line until all air bubbles have been purged from the line.

D.Do not let the water flow down the line to the tank for more than one to two minutes, or the tank may overfill.

E.Once the air is purged from the line, press the SET button and the UP button simultaneously to advance to Treated Water position.

10.Draw water from the regenerant tank.

A.From the treated water position initiate a manual regeneration.

The controller will begin a manual regen, and advance the control valve to the backwash cycle. Press the SET and UP button to advance to brine draw/slow rinse cycle.

B.With the controller in this position, check to see that the water in the regenerant tank is being drawn out of the tank. The water level in the tank should recede very slowly.

C.Observe the water being drawn from the regenerant tank for at least three minutes. If the water level does not recede, or goes up, check all hose connections. C2 should be displayed.

11.If the water level is receding from the regenerant tank you can then advance the controller back to the treated water position by pressing SET and the UP buttons simultaneously.

12.Finally, turn on a faucet plumbed after the water conditioner. Run the faucet until the water runs clear.

36

Placing Conditioner Into Operation

Rev A

 

Image 36
Contents Operations Manual Table of Contents How To Use This Manual Icons That Appear In This Manual IntroductionGeneral Warnings And Safety Information ElectricalMechanical General System Operation Cycle Functions Cycle Water Flows Equipment Installation Valve Layout Control Layout Ultramax ControllerLocation Selection Outdoor LocationsLocation Selection Rev a Water Line Connection Water Line Connection Rev a Drain Line Drain Line ConnectionRegenerant Line Connection Not used with 3-cycle filter systemOverflow Line Connection Overflow Line Connection Rev a Electrical Connection VAC AC AdaptersController Location AC Adapter Input Application Part NumberValve Camshaft Disinfection Of Water Conditioners Valve Disc OperationSodium or Calcium Hypochlorite Application 25% Sodium HypochloriteCalcium Hypochlorite Power Loss Memory Retention Ultramax ControllerMotor Controller MemoryDisplay Icons Keypad Buttons Programming ConventionsThings You Might Need to Know Setting Time of Day Programming OverviewLevel I Programming Setting Day of Week Setting Regeneration TimeSetting the Calendar Override Level II ProgrammingConditioner Operation Type Filter Operation TypeSetting Backwash Days 263 filter only Setting the Salt Amount 268 softener onlySetting Capacity Softener Default Capacity Setting Setting the Hardness conditioner onlySetting Clock Mode Setting Units of MeasureAdjusting the Cycle Times Conditioner Cycle Times Viewing the Injector TypeSetting the Service Interval Operation TypeSetting the Chlorine Generator/Salt Check conditioner only Months Since SERVICEa Level III ProgrammingPeak Flow Rate GPMa Total Water Used GAL X 100aPlacing Conditioner Into Operation Conditioner and Filter Start-UpFunction Display Text Action Key Duration Display SETRev a Performa Exploded View Performa Parts List Part Code Description QtyTroubleshooting Ultramax Series Controller TroubleshootingProblem Possible Cause Solution System Troubleshooting Intermittent or Low water pressure Rev a UltraMax System Configurations Controller Reset