Drain Line
Drain Line Connection
NOTE: Standard commercial practices are expressed here. Local codes may require changes to the following suggestions. Check with local authorities before installing a system.
1.The unit should be above and not more than 20 feet (6.1 m) from the drain. Use an appropriate adapter fitting to connect
2.If the backwash flow rate exceeds 5 gpm (22.7 Lpm) or if the unit is located
3.The drain line may be elevated up to 6 feet (1.8 m) providing the run does not exceed 15 feet (4.6 m) and water pressure at the conditioner is not less than 40 psi (2.76 bar). Elevation can increase by 2 feet (61 cm) for each additional 10 psi (.69 bar) of water pressure at the drain connector.
4.Where the drain line is elevated but empties into a drain below the level of the control valve, form a
Where the drain empties into an overhead sewer line, a
Secure the end of the drain line to prevent it from moving.
Figure 3
Drain Line Connection
Right Way
Air Gap
Drain
WARNING: Never insert drain line directly into a drain, sewer line or trap (Figure 3). Always allow an air gap between the drain line and the wastewater to prevent the possibility of sewage being
14 | Drain Line |