GE 268, 263 manual Drain Line Connection

Page 14

Drain Line

Drain Line Connection

NOTE: Standard commercial practices are expressed here. Local codes may require changes to the following suggestions. Check with local authorities before installing a system.

1.The unit should be above and not more than 20 feet (6.1 m) from the drain. Use an appropriate adapter fitting to connect 1/2-inch (1.3 cm) plastic tubing to the drain line connection of the control valve.

2.If the backwash flow rate exceeds 5 gpm (22.7 Lpm) or if the unit is located 20-40 feet (6.1-12.2 m) from drain, use 3/4-inch (1.9 cm) tubing. Use appropriate fittings to connect the 3/4-inch tubing to the 3/4-inch NPT drain connection on valve.

3.The drain line may be elevated up to 6 feet (1.8 m) providing the run does not exceed 15 feet (4.6 m) and water pressure at the conditioner is not less than 40 psi (2.76 bar). Elevation can increase by 2 feet (61 cm) for each additional 10 psi (.69 bar) of water pressure at the drain connector.

4.Where the drain line is elevated but empties into a drain below the level of the control valve, form a 7-inch (18-cm) loop at the far end of the line so that the bottom of the loop is level with the drain line connection. This will provide an adequate siphon trap.

Where the drain empties into an overhead sewer line, a sink-type trap must be used.

Secure the end of the drain line to prevent it from moving.

Figure 3

Drain Line Connection

Right Way

Air Gap

Drain

WARNING: Never insert drain line directly into a drain, sewer line or trap (Figure 3). Always allow an air gap between the drain line and the wastewater to prevent the possibility of sewage being back-siphoned into the conditioner.

14

Drain Line

Rev A

 

Image 14
Contents Operations Manual Table of Contents How To Use This Manual Icons That Appear In This Manual IntroductionMechanical General Warnings And Safety InformationElectrical General System Operation Cycle Functions Cycle Water Flows Equipment Installation Valve Layout Control Layout Ultramax ControllerLocation Selection Outdoor LocationsLocation Selection Rev a Water Line Connection Water Line Connection Rev a Drain Line Drain Line ConnectionRegenerant Line Connection Not used with 3-cycle filter systemOverflow Line Connection Overflow Line Connection Rev a Controller Location Electrical ConnectionVAC AC Adapters AC Adapter Input Application Part NumberValve Camshaft Sodium or Calcium Hypochlorite Application Disinfection Of Water ConditionersValve Disc Operation 25% Sodium HypochloriteCalcium Hypochlorite Motor Power Loss Memory RetentionUltramax Controller Controller MemoryDisplay Icons Keypad Buttons Programming ConventionsThings You Might Need to Know Level I Programming Setting Time of DayProgramming Overview Setting Day of Week Setting Regeneration TimeConditioner Operation Type Setting the Calendar OverrideLevel II Programming Filter Operation TypeSetting Capacity Softener Default Capacity Setting Setting Backwash Days 263 filter onlySetting the Salt Amount 268 softener only Setting the Hardness conditioner onlyAdjusting the Cycle Times Conditioner Cycle Times Setting Clock ModeSetting Units of Measure Viewing the Injector TypeSetting the Service Interval Operation TypeSetting the Chlorine Generator/Salt Check conditioner only Peak Flow Rate GPMa Months Since SERVICEaLevel III Programming Total Water Used GAL X 100aFunction Display Text Placing Conditioner Into OperationConditioner and Filter Start-Up Action Key Duration Display SETRev a Performa Exploded View Performa Parts List Part Code Description QtyProblem Possible Cause Solution TroubleshootingUltramax Series Controller Troubleshooting System Troubleshooting Intermittent or Low water pressure Rev a UltraMax System Configurations Controller Reset