GE 263, 268 manual Performa Exploded View

Page 37

Performa Exploded View

4

 

 

 

 

20

 

 

 

 

7

 

 

 

 

18

 

 

 

 

6

 

 

5

 

11

 

 

3

 

 

22

 

 

 

16

8

2

 

 

 

 

 

 

 

17

 

 

 

 

 

1

 

12

 

 

 

 

 

 

 

 

9

 

 

 

 

10A

 

23

 

 

 

 

 

 

 

14

 

 

15

11

10B

 

 

 

 

 

21

 

 

19

13

Warning: Do not use the flow control ball with #10A.

Performa Exploded View

37

 

Rev A

Image 37
Contents Operations Manual Table of Contents Icons That Appear In This Manual Introduction How To Use This ManualElectrical General Warnings And Safety InformationMechanical General System Operation Cycle Functions Cycle Water Flows Equipment Installation Valve Layout Ultramax Controller Control LayoutOutdoor Locations Location SelectionLocation Selection Rev a Water Line Connection Water Line Connection Rev a Drain Line Connection Drain LineNot used with 3-cycle filter system Regenerant Line ConnectionOverflow Line Connection Overflow Line Connection Rev a VAC AC Adapters Electrical ConnectionController Location AC Adapter Input Application Part NumberValve Camshaft Valve Disc Operation Disinfection Of Water ConditionersSodium or Calcium Hypochlorite Application 25% Sodium HypochloriteCalcium Hypochlorite Ultramax Controller Power Loss Memory RetentionMotor Controller MemoryDisplay Icons Programming Conventions Keypad ButtonsThings You Might Need to Know Programming Overview Setting Time of DayLevel I Programming Setting Regeneration Time Setting Day of WeekLevel II Programming Setting the Calendar OverrideConditioner Operation Type Filter Operation TypeSetting the Salt Amount 268 softener only Setting Backwash Days 263 filter onlySetting Capacity Softener Default Capacity Setting Setting the Hardness conditioner onlySetting Units of Measure Setting Clock ModeAdjusting the Cycle Times Conditioner Cycle Times Viewing the Injector TypeOperation Type Setting the Service IntervalSetting the Chlorine Generator/Salt Check conditioner only Level III Programming Months Since SERVICEaPeak Flow Rate GPMa Total Water Used GAL X 100aConditioner and Filter Start-Up Placing Conditioner Into OperationFunction Display Text SET Action Key Duration DisplayRev a Performa Exploded View Part Code Description Qty Performa Parts ListUltramax Series Controller Troubleshooting TroubleshootingProblem Possible Cause Solution System Troubleshooting Intermittent or Low water pressure Rev a Controller Reset UltraMax System Configurations