GE 268, 263 manual System Troubleshooting

Page 40

System Troubleshooting

 

Problem

 

Possible Cause

 

Solution

 

 

 

 

 

 

1.

Brine tank

a.

Uncontrolled brine refill flow rate.

a.

Remove brine control to clean ball and seat.

 

overflow.

b.

Air leak in brine line to air check.

b.

Check all connections in brine line for leaks.

 

 

 

 

 

 

 

Refer to instructions.

 

 

c.

Drain control clogged with resin

c.

Clean drain control.

 

 

 

or other debris.

 

 

 

 

 

 

 

 

2.

Flowing or

a.

Valve stem return spring weak.

a.

Replace spring. (Contact dealer.)

 

dripping water at

b.

Debris is preventing valve disc

b.

Remove debris.

 

drain or brine line

 

 

from closing.

 

 

 

after

 

 

 

 

 

 

 

 

 

regeneration.

 

 

 

 

3.

Hard water

a.

Improper regeneration.

a.

Repeat regeneration after making certain

 

leakage after

 

 

 

correct regenerant dosage was set.

 

regeneration.

b.

Leaking of external bypass valve.

b.

Replace bypass valve. (Contact dealer.)

 

 

 

 

c.

O-ring around riser pipe

c.

Replace O-ring. (Contact dealer.)

 

 

 

damaged.

 

 

 

 

d.

Incorrect capacity.

d.

Verify appropriate regenerant amount and

 

 

 

 

 

system capacity. (Contact dealer.)

 

 

 

 

 

 

4.

Control will not

a.

Low water pressure.

a.

Make correct setting according to

 

draw brine.

 

 

 

instructions.

 

 

b.

Restricted drain line.

b.

Remove restriction.

 

 

c.

Injector plugged.

c.

Clean injector and screen.

 

 

d.

Injector defective.

d.

Replace injector and cap. (Contact dealer.)

 

 

e.

Valve disc 2 and/or 3 not closed.

e.

Remove foreign matter from disc and check

 

 

 

 

 

disc for closing by pushing in on stem.

 

 

 

 

 

Replace if needed. (Contact dealer.)

 

 

f.

Air check valve prematurely

f.

Put control momentarily into brine refill.

 

 

 

closed.

 

Replace or repair air check if needed.

 

 

 

 

 

(Contact dealer.)

5.

Control will not

a.

AC adapter or motor not

a.

Connect power.

 

regenerate

 

connected.

 

 

 

automatically.

b.

Defective motor.

b.

Replace motor. (Contact dealer.)

 

 

 

 

 

 

 

 

6.

Control

a.

Controller set incorrectly.

a.

Correct time setting according to

 

regenerates at

 

 

 

instructions.

 

wrong time of

 

 

 

 

 

day.

 

 

 

 

7.

Valve will not

a.

Low water pressure.

a.

Set pump to maintain 20 psi at softener.

 

draw brine.

b.

Restricted drain line.

b.

Change drain to remove restriction.

 

 

 

 

c.

Injector plugged.

c.

Clean injector and screen.

 

 

d.

Injector defective.

d.

Replace injector. (Contact dealer.)

 

 

e.

Air check valve closes

e.

Put control momentarily into brine/slow

 

 

 

prematurely on brine pickup

 

rinse. Replace or repair air check if needed.

 

 

 

tube.

 

(Contact dealer.)

 

 

 

 

 

 

8.

System using

a.

Foreign matter in valve causing

a.

Remove brine control and flush out foreign

 

more or less salt

 

incorrect flow rates.

 

matter. Advance control to brine/slow rinse,

 

than regenerant

 

 

 

to clean valve (after so doing position

 

setting.

 

 

 

control to "fast rinse” to remove regenerant

 

 

 

 

 

from tank).

 

 

 

 

 

 

40

Troubleshooting

Rev A

 

Image 40
Contents Operations Manual Table of Contents How To Use This Manual Icons That Appear In This Manual IntroductionElectrical General Warnings And Safety InformationMechanical General System Operation Cycle Functions Cycle Water Flows Equipment Installation Valve Layout Control Layout Ultramax ControllerLocation Selection Outdoor LocationsLocation Selection Rev a Water Line Connection Water Line Connection Rev a Drain Line Drain Line ConnectionRegenerant Line Connection Not used with 3-cycle filter systemOverflow Line Connection Overflow Line Connection Rev a Electrical Connection VAC AC AdaptersController Location AC Adapter Input Application Part NumberValve Camshaft Disinfection Of Water Conditioners Valve Disc OperationSodium or Calcium Hypochlorite Application 25% Sodium HypochloriteCalcium Hypochlorite Power Loss Memory Retention Ultramax ControllerMotor Controller MemoryDisplay Icons Keypad Buttons Programming ConventionsThings You Might Need to Know Programming Overview Setting Time of DayLevel I Programming Setting Day of Week Setting Regeneration TimeSetting the Calendar Override Level II ProgrammingConditioner Operation Type Filter Operation TypeSetting Backwash Days 263 filter only Setting the Salt Amount 268 softener onlySetting Capacity Softener Default Capacity Setting Setting the Hardness conditioner onlySetting Clock Mode Setting Units of MeasureAdjusting the Cycle Times Conditioner Cycle Times Viewing the Injector TypeSetting the Service Interval Operation TypeSetting the Chlorine Generator/Salt Check conditioner only Months Since SERVICEa Level III ProgrammingPeak Flow Rate GPMa Total Water Used GAL X 100aConditioner and Filter Start-Up Placing Conditioner Into OperationFunction Display Text Action Key Duration Display SETRev a Performa Exploded View Performa Parts List Part Code Description QtyUltramax Series Controller Troubleshooting TroubleshootingProblem Possible Cause Solution System Troubleshooting Intermittent or Low water pressure Rev a UltraMax System Configurations Controller Reset