UltraMax System Configurations
Upon initial
Use the UP and DOWN buttons to scroll through the available model numbers. Press the SET button to select the number and move to the standard programming value.
Model | System Description | Operation | System | Salt | |
Number | Type | Capacity | Amount | ||
| |||||
|
|
|
|
| |
|
|
|
|
| |
10 | 1.0 cu ft Conditioner | 268 Valve | 15 Kgrains | 3.0 lbs | |
|
|
|
|
| |
15 | 1.5 cu ft Conditioner | 268 Valve | 23 Kgrains | 4.5 lbs | |
|
|
|
|
| |
20 | 2.0 cu ft Conditioner | 268 Valve | 31 Kgrains | 6.0 lbs | |
|
|
|
|
| |
93 | Generic Filter | 263 Valve | N/A | N/A | |
|
|
|
|
| |
98 | Generic Conditioner | 268 Valve | 25 Kgrains | 9.0 lbs | |
|
|
|
|
|
Controller Reset:
If the incorrect model number is accidentally selected for the controller, you can easily reset the controller to the factory default mode. When the controller is in normal operating mode showing the time of day, perform the following steps.
1.Press the DOWN and SET buttons simultaneously and hold for 5 seconds.
2.After 5 seconds the controller will go blank. Release the buttons and the controller will scroll "MODEL NUMBER " and the selected model will be displayed.
3.If the number is correct, wait 30 seconds and the controller will automatically go back to normal operation mode.
4.If the model number is incorrect, press and hold the SET button for 5 seconds. This will default the controller back to the factory default setting. The controller will scroll "MODEL NUMBER " and the factory model number will begin flashing, meaning it can be changed. USe the UP or DOWN buttons to scroll to the correct model number. Select that number by pressing the SET button.
UltraMax System Configurations | 43 |
| Rev A |