GE manual Setting Backwash Days 263 filter only, Setting the Salt Amount 268 softener only

Page 29

NOTE: Regeneration on specific day is used to provide regeneration

when water demands are not steady. Example: If the weekdays have low usage and the weekend is high, then regeneration every three days will not meet the requirements.

The calendar override days between regeneration must be set to zero to enable regeneration on specific days.

Setting Backwash Days (263 filter only)

The 263 filter controller can be programmed to regenerate on an elapsed time period (calendar override) or by the day of the week. If you would like to regenerate on specific days select a 0 (zero) for the calendar override setting, the 263 filter will prompt you to select the days of the week in which you would like the unit to regenerate/backwash. For example, the unit could be programmed to regenerate every Monday, Wednesday and Friday.

Setting the Salt Amount (268 softener only)

Is selected by the system model number. Your Ultramax Water Treatment Dealer enters the model numbers based on the specific application requirements.

Setting Capacity

Softener Default Capacity Setting

The default capacity setting is accurately calculated when the model number is entered by the factory. The capacity can be changed to operate "custom systems". Contact your Ultramax Water Treatment Dealer before adjusting the capacity setting. Default capacities are shown in Table 1.

Filter Capacity

Filter capacity is set in gallons or cubic meters. It is programmable from 100 to 14000 gallons or 1 to 140 cubic meters of capacity. Press the SET button and the digits will begin flashing. Change the capacity by using the up and down arrows to adjust the setting. To accept the setting, press the SET button.

NOTE: (Conditioners only) A different model number must be selected to change the default capacity and salt dosage.

Setting the Hardness (conditioner only)

Hardness is set in grains per gallon (gpg) or parts per million (ppm) and should be programmed to the total hardness level of the incoming water supply. Press the SET button to make the display flash. Use the UP and DOWN buttons to adjust the hardness setting. Press the SET button when the desired setting has been reached.

Setting the Language

Level II Programming

29

 

Rev A

Image 29
Contents Operations Manual Table of Contents Icons That Appear In This Manual Introduction How To Use This ManualMechanical General Warnings And Safety InformationElectrical General System Operation Cycle Functions Cycle Water Flows Equipment Installation Valve Layout Ultramax Controller Control LayoutOutdoor Locations Location SelectionLocation Selection Rev a Water Line Connection Water Line Connection Rev a Drain Line Connection Drain LineNot used with 3-cycle filter system Regenerant Line ConnectionOverflow Line Connection Overflow Line Connection Rev a VAC AC Adapters Electrical ConnectionController Location AC Adapter Input Application Part NumberValve Camshaft Valve Disc Operation Disinfection Of Water ConditionersSodium or Calcium Hypochlorite Application 25% Sodium HypochloriteCalcium Hypochlorite Ultramax Controller Power Loss Memory RetentionMotor Controller MemoryDisplay Icons Programming Conventions Keypad ButtonsThings You Might Need to Know Level I Programming Setting Time of DayProgramming Overview Setting Regeneration Time Setting Day of WeekLevel II Programming Setting the Calendar OverrideConditioner Operation Type Filter Operation TypeSetting the Salt Amount 268 softener only Setting Backwash Days 263 filter onlySetting Capacity Softener Default Capacity Setting Setting the Hardness conditioner onlySetting Units of Measure Setting Clock ModeAdjusting the Cycle Times Conditioner Cycle Times Viewing the Injector TypeOperation Type Setting the Service IntervalSetting the Chlorine Generator/Salt Check conditioner only Level III Programming Months Since SERVICEaPeak Flow Rate GPMa Total Water Used GAL X 100aFunction Display Text Placing Conditioner Into OperationConditioner and Filter Start-Up SET Action Key Duration DisplayRev a Performa Exploded View Part Code Description Qty Performa Parts ListProblem Possible Cause Solution TroubleshootingUltramax Series Controller Troubleshooting System Troubleshooting Intermittent or Low water pressure Rev a Controller Reset UltraMax System Configurations