GE 268 Placing Conditioner Into Operation, Conditioner and Filter Start-Up, Function Display Text

Page 34

Placing Conditioner Into Operation

Conditioner and Filter Start-Up

After you have performed the previous initial power-up steps, you will need to place the conditioner into operation. Follow these steps carefully, as they differ from previous Autotrol valve instructions.

NOTE: The control valve can be started-up even if power is not yet available to the controller. The valve must be connected to the water supply. The motor can be unmounted from the valve, and the camshaft can be indexed manually counterclockwise by hand. This will allow the tank to be filled and allows regenerant draw to be tested.

Function

Display Text (268)

Display Text (263)

 

 

 

Treated Water

Ultramax (268)

Ultramax (263)

 

 

 

Regeneration

Backwash

Backwash

 

Brine Draw/Slow Rinse

Pause - Please Wait

 

Pause - Please Wait

Fast Rinse

 

Fast Rinse 1

 

 

Backwash 2

 

 

Fast Rinse 2

 

 

Brine Tank Refill

 

 

 

 

1.Remove the cover from the valve. Removing the cover will allow you to see that the camshaft is turning, and in which cycle the camshaft is currently positioned.

2.With the supply water for the system still turned off, position the bypass valve to the “not in bypass” (normal operation) position.

3.Press and release the REGEN button on the controller. The scrolling text on the display will show "DELAYED REGENERATION". Press UP to navigate to "IMMEDIATE REGENERATION".

4.Press and release SET and UP to begin regeneration. The display will show eight LEDs moving from left to right on the banner display indicating that the motor is running. Additionally, the display will show the total regeneration time remaining.

Pressing SET when the motor has stopped displays the cycle description and cycle time remaining.

5.Press and release SET and UP simultaneously to advance to each cycle.

6.Advance the control to the Backwash. See below for the cycle sequences.

7.Fill the media tank with water.

A.While the controller is in cycle (Backwash), open the water supply valve very slowly to approximately the 1/4 open position.

34

Placing Conditioner Into Operation

Rev A

 

Image 34
Contents Operations Manual Table of Contents How To Use This Manual Icons That Appear In This Manual IntroductionElectrical General Warnings And Safety InformationMechanical General System Operation Cycle Functions Cycle Water Flows Equipment Installation Valve Layout Control Layout Ultramax ControllerLocation Selection Outdoor LocationsLocation Selection Rev a Water Line Connection Water Line Connection Rev a Drain Line Drain Line ConnectionRegenerant Line Connection Not used with 3-cycle filter systemOverflow Line Connection Overflow Line Connection Rev a Controller Location Electrical ConnectionVAC AC Adapters AC Adapter Input Application Part NumberValve Camshaft Sodium or Calcium Hypochlorite Application Disinfection Of Water ConditionersValve Disc Operation 25% Sodium HypochloriteCalcium Hypochlorite Motor Power Loss Memory RetentionUltramax Controller Controller MemoryDisplay Icons Keypad Buttons Programming ConventionsThings You Might Need to Know Programming Overview Setting Time of DayLevel I Programming Setting Day of Week Setting Regeneration TimeConditioner Operation Type Setting the Calendar OverrideLevel II Programming Filter Operation TypeSetting Capacity Softener Default Capacity Setting Setting Backwash Days 263 filter onlySetting the Salt Amount 268 softener only Setting the Hardness conditioner onlyAdjusting the Cycle Times Conditioner Cycle Times Setting Clock ModeSetting Units of Measure Viewing the Injector TypeSetting the Service Interval Operation TypeSetting the Chlorine Generator/Salt Check conditioner only Peak Flow Rate GPMa Months Since SERVICEaLevel III Programming Total Water Used GAL X 100aConditioner and Filter Start-Up Placing Conditioner Into OperationFunction Display Text Action Key Duration Display SETRev a Performa Exploded View Performa Parts List Part Code Description QtyUltramax Series Controller Troubleshooting TroubleshootingProblem Possible Cause Solution System Troubleshooting Intermittent or Low water pressure Rev a UltraMax System Configurations Controller Reset