Placing Conditioner Into Operation
Conditioner and Filter Start-Up
After you have performed the previous initial
NOTE: The control valve can be
Function | Display Text (268) | Display Text (263) |
|
|
|
Treated Water | Ultramax (268) | Ultramax (263) |
|
|
|
Regeneration | Backwash | Backwash |
| Brine Draw/Slow Rinse | Pause - Please Wait |
| Pause - Please Wait | Fast Rinse |
| Fast Rinse 1 |
|
| Backwash 2 |
|
| Fast Rinse 2 |
|
| Brine Tank Refill |
|
|
|
|
1.Remove the cover from the valve. Removing the cover will allow you to see that the camshaft is turning, and in which cycle the camshaft is currently positioned.
2.With the supply water for the system still turned off, position the bypass valve to the “not in bypass” (normal operation) position.
3.Press and release the REGEN button on the controller. The scrolling text on the display will show "DELAYED REGENERATION". Press UP to navigate to "IMMEDIATE REGENERATION".
4.Press and release SET and UP to begin regeneration. The display will show eight LEDs moving from left to right on the banner display indicating that the motor is running. Additionally, the display will show the total regeneration time remaining.
Pressing SET when the motor has stopped displays the cycle description and cycle time remaining.
5.Press and release SET and UP simultaneously to advance to each cycle.
6.Advance the control to the Backwash. See below for the cycle sequences.
7.Fill the media tank with water.
A.While the controller is in cycle (Backwash), open the water supply valve very slowly to approximately the 1/4 open position.
34 | Placing Conditioner Into Operation |