GE 268, 263 manual Setting the Chlorine Generator/Salt Check conditioner only

Page 32

Setting the Chlorine Generator/Salt Check (conditioner only)

The controller has the capability to produce a low level of chlorine during the brine draw stage of regeneration. It can also sense if there is any brine present during the time when brine draw is occurring. This parameter can be adjusted to the following:

0 = Chlorine Generator with Salt Check disabled

1 = Chlorine Generator with Salt Check enabled

2 = Salt Check only

A refill sensor probe kit (P/N 3002122) must be installed for this function to work properly. After it is installed, select the desired parameter and push SET to accept the selection.

32

Level II Programming

Rev A

 

Image 32
Contents Operations Manual Table of Contents How To Use This Manual Icons That Appear In This Manual IntroductionMechanical General Warnings And Safety InformationElectrical General System Operation Cycle Functions Cycle Water Flows Equipment Installation Valve Layout Control Layout Ultramax ControllerLocation Selection Outdoor LocationsLocation Selection Rev a Water Line Connection Water Line Connection Rev a Drain Line Drain Line ConnectionRegenerant Line Connection Not used with 3-cycle filter systemOverflow Line Connection Overflow Line Connection Rev a Electrical Connection VAC AC AdaptersController Location AC Adapter Input Application Part NumberValve Camshaft Disinfection Of Water Conditioners Valve Disc OperationSodium or Calcium Hypochlorite Application 25% Sodium HypochloriteCalcium Hypochlorite Power Loss Memory Retention Ultramax ControllerMotor Controller MemoryDisplay Icons Keypad Buttons Programming ConventionsThings You Might Need to Know Level I Programming Setting Time of DayProgramming Overview Setting Day of Week Setting Regeneration TimeSetting the Calendar Override Level II ProgrammingConditioner Operation Type Filter Operation TypeSetting Backwash Days 263 filter only Setting the Salt Amount 268 softener onlySetting Capacity Softener Default Capacity Setting Setting the Hardness conditioner onlySetting Clock Mode Setting Units of MeasureAdjusting the Cycle Times Conditioner Cycle Times Viewing the Injector TypeSetting the Service Interval Operation TypeSetting the Chlorine Generator/Salt Check conditioner only Months Since SERVICEa Level III ProgrammingPeak Flow Rate GPMa Total Water Used GAL X 100aFunction Display Text Placing Conditioner Into OperationConditioner and Filter Start-Up Action Key Duration Display SETRev a Performa Exploded View Performa Parts List Part Code Description QtyProblem Possible Cause Solution TroubleshootingUltramax Series Controller Troubleshooting System Troubleshooting Intermittent or Low water pressure Rev a UltraMax System Configurations Controller Reset