Step 1VH

 

TOTAL DAYS 970

Step 2VH

 

TOTAL REGENS235

Step 3VH

 

TOTAL GALLONSGAL

Step 4VH

175 x1K

 

 

ERROR LOG

 

1- - -

 

 

RETURN TO ROTATING DISPLAY

VALVE HISTORY

(Can not be reset)

STEP 1VH – Press and simultaneously for three seconds and release, then press and simultaneously and release. If screen in step 2VH does not appear in 5 seconds the lock on the valve is activated.

STEP 2VH Days, total since start-up:This display shows the total days since startup. Press the NEXT button to go to Step 3VH. Press REGEN to return to previous step.

STEP 3VH Regenerations, total number since start-up: This display shows the total number of regenerations that have occurred since startup. Press the NEXT button to go to Step 4VH. Press REGEN to return to previous step.

STEP 4 VH Volume, total used since start-up: This display shows the total gallons treated since startup. This display will equal zero if a water meter is not installed. Press NEXT button to exit Valve History. Press REGEN to return to previous step.

Use and arrows to display sequential error codes.

14

Image 14
Contents With HP Electronics Table of Contents Job Specification Sheet On TimeRelaySoft Water Basics Operating ConditionsPre-Installation Check List Bypass valve OperationInstallation Instructions 635 User displays/settings650 Programming20 GR Installer DISPLAYS/SETTINGS635PM SET Time of DAYCycle time adjustments Softener setup6000 MIN SET 12000 MIN800 MIN MIN001 MIN 300 MINService Reminder SET Regengal342 GAL DiagnosticsReset Diagnostic Values Hold 175 x1K Valve HistoryCycle Sequence Brine ReclaimEnabled 800MINOFF Miscellaneous Water Softener Draining ProcedureWater Softener Disinfection Trouble Shooting Cause CorrectionTrouble Shooting Relay troubleshooting Problem CauseTank Assy H125 conditioner & salt keeper assembliesDescription Qty Mineral Tank Distributor AssyFront Cover and Drive Assembly Drawing no Order no Description QuantitySpacer Stack Assembly Injector CAP, Injector SCREEN, INJECTOR, Plug and O-RINGProper flow Drain line 3/4 Drain lineWater meter and meter plug Bypass valveInstallation fitting assemblies Wrench Flow Diagrams Service and Backwash Flow Diagrams Downflow Flow Diagrams Rinse and Fill H125 Specifications Factory Regeneration SettingsResults General specificationsProgramming options Reserve capacity estimate based on history of water usageService Instructions Spacer Stack Assembly Compliance TableRefill Flow Control Assembly or Refill Port Plug Page Page H125 Series Water Softeners Limited warranty