Argosy Research H-125 Series owner manual Water meter and meter plug, Bypass valve

Page 27

water meter and meter plug

ITEM NO.

ORDER NO.

DESCRIPTION

QTY.

1

15-V3151

Nut 1” QC

1

2-4

15-V3003*

Meter Assy.

1

3

15-V3118-01

Turbine Assy.

1

4

15-V3105

O-ring 215

1

5

15-V3003-01

Meter Plug Assy.**

1

*Order number 15-V3003 includes 15-V3118-01 and 15-V3103, which are item numbers 3 & 4.

**Only used if metering is not to be done (time clock units)

The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench. If necessary a pliers can be used to un- screw the nut or cap. Do not use a pipe wrench to tighten or loosen nuts or caps. Do not place screwdriver in slots on caps and/or tap with a hammer.

￿

￿

￿

￿

￿

bypass valve

ITEM NO.

ORDER NO.

DESCRIPTION

QTY.

Not Shown

15-V3191-01

Bypass 90º Vert. Assy.

 

1

15-V3151

Nut 1” Quick Connect

2

2

15-V3150

Split Ring

2

3

15-V3105

O-Ring 215

2

Not Shown

15-V3191-01

Bypass Vertical Adpt.Assy (set of 2)

1

The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench. If necessary a pliers can be used to un- screw the nut or cap. Do not use a pipe wrench to tighten or loosen nuts or caps. Do not place screwdriver in slots on caps and/or tap with a hammer.

Do not use pipe dope or other sealants on threads. Teflon tape must be used on threads of the 1” NPT connection and on the threads for the drain line connection. Teflon tape is not necessary on the nut connection nor caps because of o-ring seals.

Figure 20

Figure 21

27

Image 27
Contents With HP Electronics Table of Contents On TimeRelay Job Specification SheetOperating Conditions Soft Water BasicsBypass valve Operation Pre-Installation Check ListInstallation Instructions Programming User displays/settings650 635SET Time of DAY Installer DISPLAYS/SETTINGS635PM 20 GRSoftener setup Cycle time adjustmentsMIN SET 12000 MIN800 MIN 6000 MIN300 MIN 001 MINSET Regengal Service ReminderDiagnostics Reset Diagnostic Values Hold342 GAL Valve History 175 x1KBrine Reclaim Cycle Sequence800MIN EnabledOFF Water Softener Draining Procedure Water Softener DisinfectionMiscellaneous Cause Correction Trouble ShootingTrouble Shooting Problem Cause Relay troubleshootingMineral Tank Distributor Assy H125 conditioner & salt keeper assembliesDescription Qty Tank AssyDrawing no Order no Description Quantity Front Cover and Drive AssemblyInjector CAP, Injector SCREEN, INJECTOR, Plug and O-RING Spacer Stack AssemblyProper flow Drain line Drain line 3/4Bypass valve Water meter and meter plugInstallation fitting assemblies Wrench Flow Diagrams Service and Backwash Flow Diagrams Downflow Flow Diagrams Rinse and Fill Factory Regeneration Settings H125 SpecificationsReserve capacity estimate based on history of water usage General specificationsProgramming options ResultsService Instructions Compliance Table Spacer Stack AssemblyRefill Flow Control Assembly or Refill Port Plug Page Page H125 Series Water Softeners Limited warranty