Programming options
Reserve | Regeneration | Days | Results | |
Gallons | Type | Override | (Reserve capacity estimate based on history of water usage) | |
AUTO | DELAY | oFF | Reserve capacity automatically estimated. | |
Regeneration occurs when gallons capacity falls below the reserve capacity at the next | ||||
|
|
| Regen Set Time. | |
AUTO | DELAY | 1 to 28 | Reserve capacity automatically estimated. | |
Regeneration occurs at the next Regen Set Time when gallons capacity falls below the | ||||
|
|
| reserve capacity or the specified number of days between regenerations is reached. | |
20 to | DELAY | oFF | Reserve capacity not automatically estimated. | |
250,000 | Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0. | |||
|
| |||
oFF | DELAY | 1 to 28 | Reserve capacity not automatically estimated. | |
Regeneration occurs at the next Regen Set Time when the specified number of days | ||||
|
|
| between regenerations is reached. | |
20 to | DELAY | 1 to 28 | Reserve capacity not automatically estimated. | |
Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0 or the | ||||
250,000 | ||||
|
| specified number of days between regenerations is reached. | ||
|
|
| ||
|
|
| Reserve capacity not automatically estimated. | |
AUTO | IMMEDIATE | oFF | Regeneration occurs immediately when gallons capacity reaches 0. | |
Time of regeneration will not be allowed to be set because of regeneration will always | ||||
|
|
| ||
|
|
| occur when gallons capacity reaches 0. | |
|
|
|
| |
20 to |
|
| Reserve capacity not automatically estimated. | |
DELAY + IMMEDIATE | oFF | Regeneration occurs immediately when gallons capacity reaches 0. | ||
250,000 |
|
| Time of regeneration will not be allowed to be set because regeneration will always | |
|
|
| occur on 0. | |
|
|
| Reserve capacity automatically estimated. | |
AUTO | DELAY + IMMEDIATE | oFF | Regeneration occurs when gallons capacity falls below the reserve | |
|
|
| capacity at the next Regen Set Time or regeneration occurs immediately after | |
|
|
| 10 minutes of no water usage when gallon capacity reaches 0. | |
|
| 1 to 28 | Reserve capacity automatically estimated. | |
AUTO* | DELAY + IMMEDIATE | Regeneration occurs at the next Regen Set Time when gallons capacity | ||
*14 | falls below the reserve capacity or the specified number of days between regenerations | |||
|
|
| is reached or regeneration occurs immediately after 10 | |
|
|
| minutes of no water usage when gallon capacity reaches 0. | |
|
|
| Reserve capacity not automatically estimated. | |
20 to | DELAY + IMMEDIATE | 1 to 28 | Regeneration occurs at the next Regen Set Time when specified number of days be- | |
250,000 |
|
| tween regenerations is reached or regeneration occurs immediately after 10 minutes | |
|
|
| of no water usage when gallon capacity reaches 0. | |
|
|
|
|
*Factory settings in bold
To "lockout" access to modification settings, diagnostic and valve history displays except hardness, day override and time,
press
next,
and clock in sequence to "unlock" press![]()
next,
and clock in sequence.
OPERATING PRESSURES | GENERAL specifications |
|
| 25 | |
Minimum/Maximum | ||
OPERATING TEMPERATURES |
| 40º - 110º F |
Minimum/Maximum | ||
METER |
| ±5% |
Accuracy | ||
Flow Rate Range | 0.25 - 34 GPM | |
Gallon Range | 20 - 50,000 | |
DIMENSIONS |
| 3/4” or 1” NPT |
Drain Line | ||
Brine Line | 3/8” Poly Tube | |
Electrical Current Draw and Voltage | 0.5A 110v | |
Compatible with the following regenerants or chemicals: Sodium chloride, potassium permanganate, sodium bisulfite, sodium hydroxide, hydroxide, hydrochloric acid, chlorine and chloramines.
34