SET TIME OF DAY
SET | Step 1 |
|
|
|
|
TIME HOUR | 6:35PM | Step 2 |
SET |
| |
| |
|
TIME MINUTES | Step 3 | |
SET | 6:35PM |
|
| | Figure 9 |
RETURN TO ROTATING DISPLAY
= Up Arrow = Down Arrow
Step 1 - Press SET CLOCK.
Step 2 - Current Time (hour): Set the hour of the day using or buttons. AM/PM toggles after 12. Press NEXT to go to step 3.
Step 3 - Current Time (minutes): Set the minutes of day using or buttons. Press NEXT to exit Set Clock. Press REGEN to return to previous step.
Power Loss - Lithium battery on circuit board provides up to 2 years of time clock backup during power outages. If the power is out when battery is depleted, only time of day needs to be reset, all other values are stored in
Battery
Do not forget to reset for daylight savings time.
| |
WATER HARDNESS | |
SET | 20GR |
| |
| |
DAYS BETWEEN REGEN
SET14
REGEN TIME HOUR
SET 2:00AM
REGEN TIME MINUTES
SET 2:00AM
RETURN TO ROTATING DISPLAY
Step 1
Step 2
Step 3
Step 4
Step 5
INSTALLER DISPLAYS/SETTINGS
= Up Arrow | = Down Arrow |
Step 1 - Press NEXT and simultaneously for 3 seconds.
Step 2 - Hardness: Set the amount of total compensated hardness in grains (hardness as calcium carbonate) per gallon using or but- tons. The factory setting is 20 with value ranges from 1 to 150 in 1 grain increments. Note: The grains per gallon should be increased if soluble iron needs to be reduced. Add 3 grains of hardness for each ppm of iron present. If this display shows nA
Step 3 - Day Override: This sets the number of days between regenera- tions. If value set to “oFF” regeneration initiation is based solely on gallons used. If value is set as a number (allowable range from 1 to 28) a regen- eration initiation will be called for on that day even if sufficient number of gallons were not used to call for a regeneration. Set Day Override using or buttons: Factory setting is 14 days.
•number of days between regeneration (1 to 28); or
•“oFF”
See figure 12a & b, page
Step 4 - Regeneration Time (hour): Set the hour of day for regeneration using or buttons. AM/PM toggles after 12. The factory setting time is 2:00 a.m. This display will show “REGEN” “Immediate on zero GAL” if “Immediate” is selected on Step 12 of softener
Step 5 - Regeneration Time (minutes): Set the minutes of day for regen- eration using or buttons. This display will not be shown if system is set for immediate regeneration. Press NEXT to exit Installer Displays/Settings. Press REGEN to return to previous step.
Figure 10a