Argosy Research H-125 Series 635PM, 20 GR, SET Time of DAY, Installer DISPLAYS/SETTINGS

Page 8

SET TIME OF DAY

SET

Step 1

 

 

 

TIME HOUR

6:35PM

Step 2

SET

 

 

 

TIME MINUTES

Step 3

SET

6:35PM

 

 

Figure 9

RETURN TO ROTATING DISPLAY

= Up Arrow = Down Arrow

Step 1 - Press SET CLOCK.

Step 2 - Current Time (hour): Set the hour of the day using or buttons. AM/PM toggles after 12. Press NEXT to go to step 3.

Step 3 - Current Time (minutes): Set the minutes of day using or buttons. Press NEXT to exit Set Clock. Press REGEN to return to previous step.

Power Loss - Lithium battery on circuit board provides up to 2 years of time clock backup during power outages. If the power is out when battery is depleted, only time of day needs to be reset, all other values are stored in non-volatile memory. When time of day is flashing, replace lithium coin type 2032 battery.

Battery back-up feature will be activated after 24 hours of power.

Do not forget to reset for daylight savings time.

 

WATER HARDNESS

SET

20GR

 

 

DAYS BETWEEN REGEN

SET14

REGEN TIME HOUR

SET 2:00AM

REGEN TIME MINUTES

SET 2:00AM

RETURN TO ROTATING DISPLAY

Step 1

Step 2

Step 3

Step 4

Step 5

INSTALLER DISPLAYS/SETTINGS

= Up Arrow

= Down Arrow

Step 1 - Press NEXT and simultaneously for 3 seconds.

Step 2 - Hardness: Set the amount of total compensated hardness in grains (hardness as calcium carbonate) per gallon using or but- tons. The factory setting is 20 with value ranges from 1 to 150 in 1 grain increments. Note: The grains per gallon should be increased if soluble iron needs to be reduced. Add 3 grains of hardness for each ppm of iron present. If this display shows nA -, then system is set-up in “filter” mode or "AUTO" is not selected in softener system setup. (See page 34). Press NEXT to go to Step 3. Press REGEN to exit Installer Displays/Settings.

Step 3 - Day Override: This sets the number of days between regenera- tions. If value set to “oFF” regeneration initiation is based solely on gallons used. If value is set as a number (allowable range from 1 to 28) a regen- eration initiation will be called for on that day even if sufficient number of gallons were not used to call for a regeneration. Set Day Override using or buttons: Factory setting is 14 days.

number of days between regeneration (1 to 28); or

“oFF”

See figure 12a & b, page 11-12, for more detail on softener setup. Press NEXT to go to step 4. Press REGEN to return to previous step.

Step 4 - Regeneration Time (hour): Set the hour of day for regeneration using or buttons. AM/PM toggles after 12. The factory setting time is 2:00 a.m. This display will show “REGEN” “Immediate on zero GAL” if “Immediate” is selected on Step 12 of softener set-up. See page 34. Press NEXT to go to step 5. Press REGEN to return to previous step.

Step 5 - Regeneration Time (minutes): Set the minutes of day for regen- eration using or buttons. This display will not be shown if system is set for immediate regeneration. Press NEXT to exit Installer Displays/Settings. Press REGEN to return to previous step.

Figure 10a

8

Image 8
Contents With HP Electronics Table of Contents Job Specification Sheet On TimeRelaySoft Water Basics Operating ConditionsPre-Installation Check List Bypass valve OperationInstallation Instructions User displays/settings 650635 ProgrammingInstaller DISPLAYS/SETTINGS 635PM20 GR SET Time of DAYCycle time adjustments Softener setupSET 12000 MIN 800 MIN6000 MIN MIN001 MIN 300 MINService Reminder SET Regengal342 GAL DiagnosticsReset Diagnostic Values Hold 175 x1K Valve HistoryCycle Sequence Brine ReclaimEnabled 800MINOFF Miscellaneous Water Softener Draining ProcedureWater Softener Disinfection Trouble Shooting Cause CorrectionTrouble Shooting Relay troubleshooting Problem CauseH125 conditioner & salt keeper assemblies Description QtyTank Assy Mineral Tank Distributor AssyFront Cover and Drive Assembly Drawing no Order no Description QuantitySpacer Stack Assembly Injector CAP, Injector SCREEN, INJECTOR, Plug and O-RINGProper flow Drain line 3/4 Drain lineWater meter and meter plug Bypass valveInstallation fitting assemblies Wrench Flow Diagrams Service and Backwash Flow Diagrams Downflow Flow Diagrams Rinse and Fill H125 Specifications Factory Regeneration SettingsGeneral specifications Programming optionsResults Reserve capacity estimate based on history of water usageService Instructions Spacer Stack Assembly Compliance TableRefill Flow Control Assembly or Refill Port Plug Page Page H125 Series Water Softeners Limited warranty