Argosy Research H-125 Series owner manual Front Cover and Drive Assembly

Page 23

FRONT COVER AND DRIVE ASSEMBLY

DRAWING NO.

ORDER NO.

DESCRIPTION

 

QUANTITY

 

1

15-V3529-01-H125

Front Cover Assembly Black

 

1

2

15-V3107-01

Motor Assembly

 

1

3

15-V3106-01

Drive Bracket & Spring Clip

 

1

4

15-V3578HP

H125 PC Board

 

1

5

15-V3110

Drive Gear 12x36

 

3

6

15-V3109

Drive Gear Cover

 

1

Not Shown

99-316-A001-K

Optional Relay Kit-PCM

 

1

Not Shown

99-316-A002-K

Optional Relay Kit-120V Pigtail

 

 

Not Shown

15-V3009

Auxilliary Switch Kit

 

 

 

RELAY MODEL AND DESCRIPTION

Relay Socket

65-SH2B-O5C (2 pole socket)

Relay

65-RH2B-VT DC12V (12V DC DPDT magnetic relay)

Relay Specifications: To insure proper fit and correct operation the following relay and relay socket manufactured by Idec or the exact equivalent should be used.

WIRING FOR CORRECT ON/OFF OPERATION

PC Board Relay Terminal Block

Relay Socket

RLY 1

#13

V+ (Center)

#14

RLY 2 (Bottom)

 

The relay supplies 2 sets of dry contacts for user applications. The wiring of these contacts is application specific.

NOTE: Board Revision 219 and higher - there is a connection for twin alternating system.

23

Image 23
Contents With HP Electronics Table of Contents On TimeRelay Job Specification SheetOperating Conditions Soft Water BasicsBypass valve Operation Pre-Installation Check ListInstallation Instructions Programming User displays/settings650 635SET Time of DAY Installer DISPLAYS/SETTINGS635PM 20 GRSoftener setup Cycle time adjustmentsMIN SET 12000 MIN800 MIN 6000 MIN300 MIN 001 MINSET Regengal Service Reminder342 GAL DiagnosticsReset Diagnostic Values Hold Valve History 175 x1KBrine Reclaim Cycle Sequence800MIN EnabledOFF Miscellaneous Water Softener Draining ProcedureWater Softener Disinfection Cause Correction Trouble ShootingTrouble Shooting Problem Cause Relay troubleshootingMineral Tank Distributor Assy H125 conditioner & salt keeper assembliesDescription Qty Tank AssyDrawing no Order no Description Quantity Front Cover and Drive AssemblyInjector CAP, Injector SCREEN, INJECTOR, Plug and O-RING Spacer Stack AssemblyProper flow Drain line Drain line 3/4Bypass valve Water meter and meter plugInstallation fitting assemblies Wrench Flow Diagrams Service and Backwash Flow Diagrams Downflow Flow Diagrams Rinse and Fill Factory Regeneration Settings H125 SpecificationsReserve capacity estimate based on history of water usage General specificationsProgramming options ResultsService Instructions Compliance Table Spacer Stack AssemblyRefill Flow Control Assembly or Refill Port Plug Page Page H125 Series Water Softeners Limited warranty