Argosy Research H-125 Series owner manual 800MIN, Enabled

Page 16

RECLAMATION MODE

SET ENABLED

RECLAIM START

SET 30:00MIN Step 4CS

 

 

RECLAIM DURATION

Step 5CS

SET

8:00MIN

 

 

ALTERNATOR SYSTEM

 

SET

ALT A Step 6CS

 

 

NO HARD BYPASS

Step 7CS

SET

ENABLED

 

 

 

 

 

Only displays if reclamation of brine is enabled in Step 3CS. Selection requires that a connec- tion to a MAV is made to the two-pin connector labeled DRIVE on PC Board.

Press NEXT to go to Step 4CS. Press REGEN to return to previous step.

STEP 4CS – Use the or buttons to select the number of minutes after the start of the draw cycle before the MAV will divert the brine waste water from the plumbing drain receptacle to the brine tank. Press NEXT to select duration of brine reclaim.

STEP 5CS – Only displays if reclamation of brine is enabled in Step 3CS. Use the or but- tons to select the number of minutes to divert the brine waste water to the brine tank. After the minutes count down to zero the waste water will once again be diverted to the plumbing drain receptacle.

Press NEXT to go to Step 8CS. Press REGEN to return to previous step.

STEP 6CS Twin Alternating SystemAllows automatic alternation between two units to provide softened water 24 hours a day.

Use or buttons to select ALT A or ALT B. Selection requires connection to a MAV is made. Select ALT A for the control valve that has the two pin connector labeled DRIVE connected to the MAV (motorized alternator valve).

Select ALT B for the control valve that will not be connected to the alternator valve motor.

Must do one of the following:

• If set up for a softener, Volume Capacity in GALLONS, select

Regeneration Time Option “IMMEDIATE” and select DAYS BETWEEN REGEN “OFF”.

• For additional programming information, refer to MAV manual.

Press NEXT to go to Step 8CS. Press REGEN to return to previous step.

STEP 7CS – No Hard Water Bypass Enabled - Use or buttons to select NO HARD WATER BYPASS ENABLE. Selection requires that a connection to a Motorized Alternator Valve (MAV) is made to the two pin connector labeled ALTERNATOR DRIVE located on the printed circuit board. The MAV will be driven closed before the first regeneration cycle that is not FILL or SOFTENING or FILTERING, and be driven open after the last regeneration cycle that is not FILL.

Press NEXT to go to Step 8CS. Press REGEN to return to previous step.

16

Image 16
Contents With HP Electronics Table of Contents Job Specification Sheet On TimeRelaySoft Water Basics Operating ConditionsPre-Installation Check List Bypass valve OperationInstallation Instructions User displays/settings 650635 ProgrammingInstaller DISPLAYS/SETTINGS 635PM20 GR SET Time of DAYCycle time adjustments Softener setupSET 12000 MIN 800 MIN6000 MIN MIN001 MIN 300 MINService Reminder SET RegengalReset Diagnostic Values Hold Diagnostics342 GAL 175 x1K Valve HistoryCycle Sequence Brine ReclaimEnabled 800MINOFF Water Softener Disinfection Water Softener Draining ProcedureMiscellaneous Trouble Shooting Cause CorrectionTrouble Shooting Relay troubleshooting Problem CauseH125 conditioner & salt keeper assemblies Description QtyTank Assy Mineral Tank Distributor AssyFront Cover and Drive Assembly Drawing no Order no Description QuantitySpacer Stack Assembly Injector CAP, Injector SCREEN, INJECTOR, Plug and O-RINGProper flow Drain line 3/4 Drain lineWater meter and meter plug Bypass valveInstallation fitting assemblies Wrench Flow Diagrams Service and Backwash Flow Diagrams Downflow Flow Diagrams Rinse and Fill H125 Specifications Factory Regeneration SettingsGeneral specifications Programming optionsResults Reserve capacity estimate based on history of water usageService Instructions Spacer Stack Assembly Compliance TableRefill Flow Control Assembly or Refill Port Plug Page Page H125 Series Water Softeners Limited warranty