AUTO STOP

6. Timer

<Checking the Current Auto Off Timer Setting>

¢Timer Setting

TIMER

AFTER

OFF

AUTO OFF ¡

1.Be sure that the “Auto Off” is visible on the screen (at ¡).

2.Hold down the Timer Menu button w for 3 seconds, so that “Monitor” is indicated on the screen (at ¢).

• The timer remaining to shutdown appears at .

3.To close the monitor and return to the standard control screen, press the Mode (Return) button 2.

<To Turn Off the Auto Off Timer...>

Hold down the Timer On/Off button 9 for 3 seconds, so that “Timer Off” appears (at §) and the timer value (at ) disappears.

 

 

˚F

§

˚F

AUTO OFF

Alternatively, turn off the air conditioner itself. The timer value (at ) will disappear from the screen.

AUTO OFF

<To Turn On the Auto Off Timer...>

Hold down the Timer On/Off button 9 for 3 seconds. The “Timer Off” indication disappears (at §), and the timer setting comes on the display (at ).

Alternatively, turn on the air conditioner. The timer value will appear at .

 

AFTER

OFF

 

˚F

˚F

§

 

 

AUTO OFF

6.2. For wireless remote controller

A

13

2

1 Press the AUTO STOP or AUTO START button (TIMER SET).

Time can be set while the following symbol is blinking. OFF timer: A is blinking.

ON timer: A is blinking.

2 Use the

h

min

and

buttons to set the desired time.

3Canceling the timer.

To cancel the OFF timer, press the button.

To cancel the ON timer, press the AUTO START button.

It is possible to combine both OFF and ON timers.

Pressing the 1 ON/OFF button of the remote controller during timer mode to stop the unit will cancel the timers.

If the current time has not been set, the timer operation cannot be used.

7. Other Functions

7.1. Locking the Remote Controller Buttons (Operation function limit controller)

If you wish, you can lock the remote controller buttons. You can use the Function Selection of remote controller to select which type of lock to use. (For information about selecting the lock type, see section 8, item [4]–2 (1)).

Specifically, you can use either of the following two lock types.

1 Lock All Buttons:

Locks all of the buttons on the remote controller.

2Lock All Except ON/OFF:

Locks all buttons other than the ON/OFF button.

Note:

The “Locked” indicator appears on the screen to indicate that buttons are cur-

<How to Lock the Buttons>

1.While holding down the Filter button 4, press and hold down the ON/OFF button 1 for 2 seconds. The “Locked” indication appears on the screen (at ¡), indicating that the lock is now engaged.

*If locking has been disabled in Function Selection of remote controller, the screen will display the “Not Available” message when you press the buttons as described above.

¡

FUNCTION

˚F

˚F

If you press a locked button, the “Locked” indication (at ¡) will blink on the display.

rently locked.

TIME SUN

FUNCTION

˚F

˚F

 

TEMP.

 

 

ON/OFF

 

MENU

ON/OFF

 

FILTER

BACK

MONITOR/SET

DAY

 

CHECK TEST

PAR-21MAA

CLOCK

OPERATION

CLEAR

¡

Lock Indicator

1

4

¡

FUNCTION

˚F

˚F

<How to Unlock the Buttons>

1.While holding down the Filter button 4, press and hold down the ON/ OFF button 1for 2 seconds—so that the “Locked” indication disappears from the screen (at ¡).

¡

˚F

˚F

11

Image 11
Contents Air-Conditioners Parts Names ContentsSafety Precautions PCA-A·GA Ceiling Suspended PKA-A·GA/PKA-A·GAL Wall MountedPKA-A·FA/PKA-A·FAL Wall Mounted Temp Wired Remote-ControllerDisplay Section Operation SectionWireless Remote-Controller Battery installation/replacementTurning ON/OFF Screen ConfigurationSetting the Day of the Week and Time OperationAirflow direction setting Mode selectTemperature setting Fan speed settingVentillation TimerFor Wired Remote-controller Timer Off indication is no longer displayed Simple TimerExamples How to Set the Auto Off Timer Auto Off TimerTimer value is visible and appropriate Viewing the Current Simple Timer SettingsOther Functions For wireless remote controllerFunction Selection Error Codes indicationFunction selection of remote controller Setting language English Function selection flowchartDetailed setting Japanese Dot display tableWhen the remote controller cannot be used Emergency Operation for Wireless Remote-controllerCare and Cleaning Trouble ShootingHigh sound Normal rooms Low sound Absorbing rooms Location Replace the batteries and press the Reset buttonController Simple , or Auto OFF appearsWET CFM SpecificationsFLA MCA Mocp DRY CFMPage Nombres de las piezas ContenidoMedidas de Seguridad PKA-A·FA/PKA-A·FAL Modelo montado en pared PKA-A·GA/PKA-A·GAL Modelo montado en paredFiltro Entrada de aire Rejilla Salida de aireTemp ON/OFF Sección de pantallaSección de control Para controlador remoto cableadoInicial Instalación/sustitución de pilasPara controlador remoto inalámbrico InteriorEncendido y apagado Configuración de la pantallaConfiguración de día de la semana y hora ManejoAjuste de la dirección del flujo de aire Selección de modoAjuste de la temperatura Ajuste de la velocidad del ventiladorPara controlador remoto cableado TemporizadorVentilación Para desactivar el temporizador semanal De que ya no se muestre el indicador Timer OffCómo configurar el temporizador simple Temporizador simpleTemporizador de apagado automático Para controlador remoto inalámbrico Otras funcionesSelección de funciones del controlador remoto Indicación de códigos de errorSelección de función Idioma ajustado inglés Ajuste detallado Tabla del indicador de puntos Refrigeración Calefacción Mantenimiento y limpiezaLocalización de fallos Cuando no puede utilizar el controlador remotoVOR, Espere ENCENDIDO/APAGADOEspecificaciones Specifications are subject to change without notice