9. Emergency Operation for Wireless Remote-controller

BA

ON STAND COOL HEAT

OFF BY

E D C

When the remote controller cannot be used

When the batteries of the remote controller run out or the remote controller malfunctions, the emergency operation can be done using the emergency buttons on the grille.

ADEFROST/STAND BY lamp BOperation lamp

CEmergency operation switch (heating) DEmergency operation switch (cooling) EReceiver

Starting operation

To operate the cooling mode, press the button D.

To operate the heating mode, press the button C.

Note:

Details of emergency mode are as shown below.

Details of EMERGENCY MODE are as shown below.

Operation mode

 

COOL

 

HEAT

Set temperature

 

24°C, 75°F

 

24°C, 75°F

Fan speed

 

High

 

High

Airflow direction

 

Horizontal

 

Downward 4

Stopping operation

 

 

 

• To stop operation, press the

button D or the

button C.

10. Care and Cleaning

˚F

˚F

FILTER

 

 

TEMP. ON/OFF

Indicates that the filter needs cleaning. Ask authorized people to clean the filter.

When resetting “FILTER” display

When the [FILTER] button is pressed two times successively after cleaning the filter, the display goes off and is reset.

Note:

When two or more different types of indoor unit are controlled, the cleaning period differs with the type of filter. When the master unit cleaning period arrives, “FILTER” is displayed. When the filter display goes off, the cumula- tive time is reset.

“FILTER” indicates the cleaning period when the air conditioner was used under general indoor air conditions by criteria time. Since the degree of dirti- ness depends on the environmental conditions, clean the filter accordingly.

The filter cleaning period cumulative time differs with the model.

This indication is not available for wireless remote controller.

11. Trouble Shooting

Having trouble?

Here is the solution. (Unit is operating normally.)

Air conditioner does not heat or cool well.

Clean the filter. (Airflow is reduced when the filter is dirty or clogged.)

 

Check the temperature adjustment and adjust the set temperature.

 

Make sure that there is plenty of space around the outdoor unit. Is the

 

indoor unit air intake or outlet blocked?

 

Has a door or window been left open?

When heating operation starts, warm air does not blow from the indoor unit

Warm air does not blow until the indoor unit has sufficiently warmed up.

soon.

 

During heating mode, the air conditioner stops before the set room tem-

When the outdoor temperature is low and the humidity is high, frost may

perature is reached.

form on the outdoor unit. If this occurs, the outdoor unit performs a de-

 

frosting operation. Normal operation should begin after approximately 10

 

minutes.

Airflow direction changes during operation or airflow direction cannot be

During cooling mode, the vanes automatically move to the horizontal

set.

(down) position after 1 hour when the down (horizontal) airflow direction

 

is selected. This is to prevent water from forming and dripping from the

 

vanes.

 

During heating mode, the vanes automatically move to the horizontal

 

airflow direction when the airflow temperature is low or during defrosting

 

mode.

When the airflow direction is changed, the vanes always move up and down

When the airflow direction is changed, the vanes move to the set position

past the set position before finally stopping at the position.

after detecting the base position.

A flowing water sound or occasional hissing sound is heard.

These sounds can be heard when refrigerant is flowing in the air condi-

 

tioner or when the refrigerant flow is changing.

A cracking or creaking sound is heard.

These sounds can be heard when parts rub against each due to expan-

 

sion and contraction from temperature changes.

The room has an unpleasant odor.

The indoor unit draws in air that contains gases produced from the walls,

 

carpeting, and furniture as well as odors trapped in clothing, and then

 

blows this air back into the room.

A white mist or vapor is emitted from the indoor unit.

If the indoor temperature and the humidity are high, this condition may

 

occur when operation starts.

 

During defrosting mode, cool airflow may blow down and appear like a

 

mist.

Water or vapor is emitted from the outdoor unit.

During cooling mode, water may form and drip from the cool pipes and

 

joints.

 

During heating mode, water may form and drip from the heat exchanger.

 

During defrosting mode, water on the heat exchanger evaporates and

 

water vapor may be emitted.

The operation indicator does not appear in the remote controller display.

Turn on the power switch. “ ” will appear in the remote controller display.

 

 

16

Image 16
Contents Air-Conditioners Safety Precautions ContentsParts Names PKA-A·FA/PKA-A·FAL Wall Mounted PKA-A·GA/PKA-A·GAL Wall MountedPCA-A·GA Ceiling Suspended Wired Remote-Controller Display SectionOperation Section TempBattery installation/replacement Wireless Remote-ControllerScreen Configuration Setting the Day of the Week and TimeOperation Turning ON/OFFMode select Temperature settingFan speed setting Airflow direction settingFor Wired Remote-controller TimerVentillation Simple Timer Timer Off indication is no longer displayedAuto Off Timer Timer value is visible and appropriateViewing the Current Simple Timer Settings Examples How to Set the Auto Off TimerFor wireless remote controller Other FunctionsFunction selection of remote controller Error Codes indicationFunction Selection Function selection flowchart Setting language EnglishDetailed setting Dot display table JapaneseEmergency Operation for Wireless Remote-controller Care and CleaningTrouble Shooting When the remote controller cannot be usedReplace the batteries and press the Reset button ControllerSimple , or Auto OFF appears High sound Normal rooms Low sound Absorbing rooms LocationSpecifications FLA MCA MocpDRY CFM WET CFMPage Medidas de Seguridad ContenidoNombres de las piezas PKA-A·GA/PKA-A·GAL Modelo montado en pared Filtro Entrada de aireRejilla Salida de aire PKA-A·FA/PKA-A·FAL Modelo montado en paredSección de pantalla Sección de controlPara controlador remoto cableado Temp ON/OFFInstalación/sustitución de pilas Para controlador remoto inalámbricoInterior InicialConfiguración de la pantalla Configuración de día de la semana y horaManejo Encendido y apagadoSelección de modo Ajuste de la temperaturaAjuste de la velocidad del ventilador Ajuste de la dirección del flujo de aireVentilación TemporizadorPara controlador remoto cableado De que ya no se muestre el indicador Timer Off Cómo configurar el temporizador simpleTemporizador simple Para desactivar el temporizador semanalTemporizador de apagado automático Otras funciones Para controlador remoto inalámbricoSelección de función Indicación de códigos de errorSelección de funciones del controlador remoto Idioma ajustado inglés Ajuste detallado Tabla del indicador de puntos Mantenimiento y limpieza Localización de fallosCuando no puede utilizar el controlador remoto Refrigeración CalefacciónENCENDIDO/APAGADO VOR, EspereEspecificaciones Specifications are subject to change without notice