Mitsubishi Electronics PCA-AGA Screen Configuration, Setting the Day of the Week and Time

Page 6
Horiz. outlet *
Last setting
Horiz. outlet *
Airflow up/down
Mode
Temperature setting
Fan speed

3. Screen Configuration

Function Selection of remote controller

Set Day/Time

 

TIME SUN

 

A

D

C

Standard Control Screens

 

 

˚F

˚F

OFF

ON

B C

Timer Monitor

Timer Setup

MON

SUN MON TUE

WED THU

FRI SAT

TIMER

 

 

 

OFF

B

 

 

˚F

 

 

WEEKLY

 

 

WEEKLY

<Screen Types>

For details on setting the language for the remote controller display, refer to section 8. Function Selection.

The initial language setting is English.

Function Selection of remote controller:

 

Set the functions and ranges available to the re-

 

mote controller (timer functions, operating restric-

 

tions, etc.)

Set Day/Time:

Set the current day of the week or time.

Standard Control Screens:

 

View and set the air conditioning system’s oper-

 

ating status

Timer Monitor:

View the currently set timer (weekly timer, sim-

 

ple timer, or Auto Off timer)

Timer Setup:

Set the operation of any of the timers (weekly

 

timer, simple timer, or Auto Off timer).

<How to change the screen>

A:Hold down both the Mode button and the Timer On/Off button for 2 seconds.

B:Press the Timer Menu button.

C :Press the Mode (Return) button.

D :Press either of the Set Time buttons ( or ).

4. Setting the Day of the Week and Time

2

q

Note:

TIME SUN

˚F

˚F

 

TEMP.

 

 

ON/OFF

 

MENU

ON/OFF

 

FILTER

BACK

MONITOR/SET

DAY

 

CHECK TEST

PAR-21MAA

CLOCK

OPERATION

CLEAR

¡

Day of the Week & Time display

9

4

£Day of the Week Setting

TIME SUN

¢ Time Setting

 

 

1.

Press the

or

Set Time button q to show display .

2.

Press the Timer On/Off (Set Day) button 9 to set the day.

 

* Each press advances the day shown at £: Sun Mon ... Fri

 

Sat.

 

 

3. Press the appropriate Set Time button q as necessary to set the time.

 

* As you hold the button down, the time (at ¢) will increment first in

 

minute intervals, then in ten-minute intervals, and then in one-hour in-

The day and time will not appear if clock use has been disabled at Function Selection of remote controller.

tervals.

4. After making the appropriate settings at Steps 2 and 3, press the Filter

button 4 to lock in the values.

5. Operation

£

3

2

˚F

TEMP.

MENU ON/OFF

BACK MONITOR/SET DAY

PAR-21MAACLOCK

˚F

ON/OFF

FILTER

CHECK TEST

OPERATION

CLEAR

§

¢

¡

1

5

£

§

 

13

7 8 6

5.1. Turning ON/OFF

<To Start Operation>

Press the ON/OFF button 1.

The ON lamp ¡ and the display area come on.

Note:

When the unit is restarted, initial settings are as follows.

5

2 6

7

Remote Controller settings

Last operation mode

Last set temperature

Last set fan speed

COOL or DRY

Mode HEAT

FAN

* It will be set by last setting for wired remote controller.

6

Image 6
Contents Air-Conditioners Contents Safety PrecautionsParts Names PKA-A·GA/PKA-A·GAL Wall Mounted PKA-A·FA/PKA-A·FAL Wall MountedPCA-A·GA Ceiling Suspended Operation Section Wired Remote-ControllerDisplay Section TempBattery installation/replacement Wireless Remote-ControllerOperation Screen ConfigurationSetting the Day of the Week and Time Turning ON/OFFFan speed setting Mode selectTemperature setting Airflow direction settingTimer For Wired Remote-controllerVentillation Simple Timer Timer Off indication is no longer displayedViewing the Current Simple Timer Settings Auto Off TimerTimer value is visible and appropriate Examples How to Set the Auto Off TimerFor wireless remote controller Other FunctionsError Codes indication Function selection of remote controllerFunction Selection Function selection flowchart Setting language EnglishDetailed setting Dot display table JapaneseTrouble Shooting Emergency Operation for Wireless Remote-controllerCare and Cleaning When the remote controller cannot be usedSimple , or Auto OFF appears Replace the batteries and press the Reset buttonController High sound Normal rooms Low sound Absorbing rooms LocationDRY CFM SpecificationsFLA MCA Mocp WET CFMPage Contenido Medidas de SeguridadNombres de las piezas Rejilla Salida de aire PKA-A·GA/PKA-A·GAL Modelo montado en paredFiltro Entrada de aire PKA-A·FA/PKA-A·FAL Modelo montado en paredPara controlador remoto cableado Sección de pantallaSección de control Temp ON/OFFInterior Instalación/sustitución de pilasPara controlador remoto inalámbrico InicialManejo Configuración de la pantallaConfiguración de día de la semana y hora Encendido y apagadoAjuste de la velocidad del ventilador Selección de modoAjuste de la temperatura Ajuste de la dirección del flujo de aireTemporizador VentilaciónPara controlador remoto cableado Temporizador simple De que ya no se muestre el indicador Timer OffCómo configurar el temporizador simple Para desactivar el temporizador semanalTemporizador de apagado automático Otras funciones Para controlador remoto inalámbricoIndicación de códigos de error Selección de funciónSelección de funciones del controlador remoto Idioma ajustado inglés Ajuste detallado Tabla del indicador de puntos Cuando no puede utilizar el controlador remoto Mantenimiento y limpiezaLocalización de fallos Refrigeración CalefacciónENCENDIDO/APAGADO VOR, EspereEspecificaciones Specifications are subject to change without notice