Mitsubishi Electronics PKA-AGA, PCA-AGA, PLA-AAA, PKA-AFA Contents, Safety Precautions, Parts Names

Page 2

Contents

1.

Safety Precautions

2

7.

Other Functions

11

2.

Parts Names

2

8.

Function Selection

12

3.

Screen Configuration

6

9.

Emergency Operation for Wireless Remote-controller

16

4.

Setting the Day of the Week and Time

6

10.

Care and Cleaning

16

5.

Operation

6

11.

Trouble Shooting

16

6.

Timer

8

12.

Specifications

18

1. Safety Precautions

sBefore installing the unit, make sure you read all the “Safety Precautions”.

sThe “Safety Precautions” provide very important points regarding safety. Make sure you follow them.

sPlease report to or take consent by the supply author- ity before connection to the system.

Symbols used in the text

Warning:

Describes precautions that should be observed to prevent danger of injury or death to the user.

Caution:

Describes precautions that should be observed to prevent damage to the unit.

Symbols used in the illustrations

: Indicates a part which must be grounded.

Warning:

The unit must not be installed by the user. Ask the dealer or an authorized company to install the unit. If the unit is installed im- properly, water leakage, electric shock or fire may result.

Do not stand on, or place any items on the unit.

Do not splash water over the unit and do not touch the unit with wet hands. An electric shock may result.

Do not spray combustible gas close to the unit. Fire may result.

Do not place a gas heater or any other open-flame appliance where it will be exposed to the air discharged from the unit. Incomplete combustion may result.

Do not remove the front panel or the fan guard from the outdoor unit when it is running.

When you notice exceptionally abnormal noise or vibration, stop operation, turn off the power switch, and contact your dealer.

Never insert fingers, sticks etc. into the intakes or outlets.

If you detect odd smells, stop using the unit, turn off the power switch and consult your dealer. Otherwise, a breakdown, electric shock or fire may result.

This air conditioner is NOT intended for use by children or infirm persons without supervision.

Young children must be supervised to ensure that they do not play with the air conditioner.

If the refrigeration gas blows out or leaks, stop the operation of the air conditioner, thoroughly ventilate the room, and contact your dealer.

Caution:

Disposing of the unit

• Do not use any sharp object to push the buttons, as this may dam-

When you need to dispose of the unit, consult your dealer.

age the remote controller.

 

Never block or cover the indoor or outdoor unit’s intakes or out- lets.

2. Parts Names

Indoor Unit

 

PLA-A·AA

PKA-A·GA

PKA-A·FA

PCA-A·GA

 

PKA-A·GAL

PKA-A·FAL

 

 

 

 

 

 

 

 

Fan steps

4 steps

4 steps

2 steps

4 steps

Vane

Auto with swing

Auto with swing

Auto with swing

Auto with swing

Louver

Manual

Manual

Manual

Filter

Long-life

Normal

Normal

Long-life

Filter cleaning indication

2,500 hr

100 hr

100 hr

2,500 hr

2

Image 2
Contents Air-Conditioners Parts Names ContentsSafety Precautions PCA-A·GA Ceiling Suspended PKA-A·GA/PKA-A·GAL Wall MountedPKA-A·FA/PKA-A·FAL Wall Mounted Operation Section Wired Remote-ControllerDisplay Section TempBattery installation/replacement Wireless Remote-ControllerOperation Screen ConfigurationSetting the Day of the Week and Time Turning ON/OFFFan speed setting Mode selectTemperature setting Airflow direction settingVentillation TimerFor Wired Remote-controller Simple Timer Timer Off indication is no longer displayedViewing the Current Simple Timer Settings Auto Off TimerTimer value is visible and appropriate Examples How to Set the Auto Off TimerFor wireless remote controller Other FunctionsFunction Selection Error Codes indicationFunction selection of remote controller Function selection flowchart Setting language EnglishDetailed setting Dot display table JapaneseTrouble Shooting Emergency Operation for Wireless Remote-controllerCare and Cleaning When the remote controller cannot be usedSimple , or Auto OFF appears Replace the batteries and press the Reset buttonController High sound Normal rooms Low sound Absorbing rooms LocationDRY CFM SpecificationsFLA MCA Mocp WET CFMPage Nombres de las piezas ContenidoMedidas de Seguridad Rejilla Salida de aire PKA-A·GA/PKA-A·GAL Modelo montado en paredFiltro Entrada de aire PKA-A·FA/PKA-A·FAL Modelo montado en paredPara controlador remoto cableado Sección de pantallaSección de control Temp ON/OFFInterior Instalación/sustitución de pilasPara controlador remoto inalámbrico InicialManejo Configuración de la pantallaConfiguración de día de la semana y hora Encendido y apagadoAjuste de la velocidad del ventilador Selección de modoAjuste de la temperatura Ajuste de la dirección del flujo de airePara controlador remoto cableado TemporizadorVentilación Temporizador simple De que ya no se muestre el indicador Timer OffCómo configurar el temporizador simple Para desactivar el temporizador semanalTemporizador de apagado automático Otras funciones Para controlador remoto inalámbricoSelección de funciones del controlador remoto Indicación de códigos de errorSelección de función Idioma ajustado inglés Ajuste detallado Tabla del indicador de puntos Cuando no puede utilizar el controlador remoto Mantenimiento y limpiezaLocalización de fallos Refrigeración CalefacciónENCENDIDO/APAGADO VOR, EspereEspecificaciones Specifications are subject to change without notice