Mitsubishi Electronics PKA-AGA, PCA-AGA, PLA-AAA Timer, Ventillation, For Wired Remote-controller

Page 8

5. Operation

<To Change the Right/Left Air Direction>

Press the louver button 7 as necessary.

The louver image appears.

Each press of the button switches the setting as follows.

 

 

 

 

No display

During swing operation, the arrow dis-

 

 

 

 

 

 

 

(Stop)

 

 

 

 

play move to the left and right.

(ON)

 

 

 

(OFF)

 

 

 

 

5.6. Ventillation

sFor LOSSNAY combination

5.6.1.For Wired Remote-controller

To run the ventilator together with the indoor unit:

Press the ON/OFF button 1.

The Vent indication appears on the screen (at ). The ventilator will now automatically operate whenever the indoor unit is running.

To run the ventilator independently:

Press the Mode button 2 until appears on the display. This will cause the ventilator to start.

To change the ventilator force:

Press the Ventilation button 8 as necessary.

• Each press toggles the setting, as shown below.

LowHigh

5.6.2. For Wireless Remote-controller

The ventillator will automatically operate when the indoor unit turns on.

No indication on the wireless remote controller.

6. Timer

6.1. For Wired Remote-controller

You can use Function Selection of remote controller to select which of three types of timer to use: 1Weekly timer, 2 Simple timer, or 3 Auto Off timer.

6.1.1. Weekly Timer

The weekly timer can be used to set up to eight operations for each day of the week.

Each operation may consist of any of the following: ON/OFF time together with a temperature setting, or ON/OFF time only, or tempera- ture setting only.

When the current time reaches a time set at this timer, the air conditioner carries out the action set by the timer.

Time setting resolution for this timer is 1 minute.

Note:

*1. Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same time.

*2. The weekly timer will not operate when any of the following conditions is in effect.

The timer feature is off; the system is in an malfunction state; a test run is in progress; the remote controller is undergoing self-check or remote con- troller check; the user is in the process of setting a function; the user is in the process of setting the timer; the user is in the process of setting the current day of the week or time; the system is under central control. (Spe- cifically, the system will not carry out operations (unit on, unit off, or tem- perature setting) that are prohibited during these conditions.)

Operation No.

¢

£ Day Setting

 

 

 

 

SUN

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

˚F

 

 

¡

 

 

 

 

 

 

 

 

 

 

WEEKLY

 

 

 

TEMP.

 

 

ON/OFF

 

3

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

w

 

MENU

ON/OFF

 

FILTER

4

 

 

 

 

 

 

BACK

MONITOR/SET

DAY

 

CHECK

TEST

0

PAR-21MAA

CLOCK

OPERATION

 

 

CLEAR

 

 

2

q

9

78

 

 

 

<How to Set the Weekly Timer>

1.Be sure that you are at a standard control screen, and that the weekly timer indicator ¡ is shown in the display.

2.Press the Timer Menu button w, so that the “Set Up” appears on the screen (at ). (Note that each press of the button toggles the display between “Set Up” and “Monitor”.)

3.Press the Timer On/Off (Set Day) button 9 to set the day. Each press

advances the display at £to the next setting, in the following sequence: “Sun Mon Tues Wed Thurs Fri Sat” “Sun” ... “Fri” “Sat” “Sun Mon Tues Wed Thurs Fri Sat”...

4.Press the or Operation button (7or 8) as necessary to select the appropriate operation number (1 to 8) ¢.

*Your inputs at Steps 3 and 4 will select one of the cells from the matrix illustrated below.

(The remote-controller display at left shows how the display would appear when setting Operation 1 for Sunday to the values indicated below.)

Setup Matrix

Op No.

Sunday

Monday

Saturday

 

 

 

 

 

 

 

 

 

No. 1

• 8:30

 

 

 

 

 

 

• ON

 

 

 

 

 

 

 

• 73 °F

 

 

 

 

 

 

No. 2

• 10:00

 

• 10:00

 

• 10:00

• 10:00

• OFF

 

• OFF

 

• OFF

• OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No. 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Operation 1 settings for Sunday>

 

<Operation 2 settings for every day>

Start the air conditioner at 8:30, with

 

Turn off the air conditioner at 10:00.

the temperature set to 73 °F.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note:

By setting the day to “Sun Mon Tues Wed Thurs Fri Sat”, you can set the same operation to be carried out at the same time every day.

(Example: Operation 2 above, which is the same for all days of the week.)

<Setting the Weekly Timer>

 

 

Shows the time

§ Shows the selected operation (ON or OFF)

setting

 

* Does not appear if operation is not set.

 

SUN

 

 

 

 

 

ON

 

 

 

˚F

 

Shows the temperature setting

 

 

WEEKLY

* Does not appear if temperature is not

 

 

 

 

set.

5.Press the appropriate Set Time button q as necessary to set the desired time (at ).

*As you hold the button down, the time first increments in minute inter- vals, then in ten-minute intervals, and then in one-hour intervals.

6.Press the ON/OFF button 1 to select the desired operation (ON or OFF), at §.

*Each press changes the next setting, in the following sequence:

No display (no setting) “ON” “OFF”

8

Image 8
Contents Air-Conditioners Parts Names ContentsSafety Precautions PCA-A·GA Ceiling Suspended PKA-A·GA/PKA-A·GAL Wall MountedPKA-A·FA/PKA-A·FAL Wall Mounted Wired Remote-Controller Display SectionOperation Section TempBattery installation/replacement Wireless Remote-ControllerScreen Configuration Setting the Day of the Week and TimeOperation Turning ON/OFFMode select Temperature settingFan speed setting Airflow direction settingVentillation TimerFor Wired Remote-controller Simple Timer Timer Off indication is no longer displayedAuto Off Timer Timer value is visible and appropriateViewing the Current Simple Timer Settings Examples How to Set the Auto Off TimerFor wireless remote controller Other FunctionsFunction Selection Error Codes indicationFunction selection of remote controller Function selection flowchart Setting language EnglishDetailed setting Dot display table JapaneseEmergency Operation for Wireless Remote-controller Care and CleaningTrouble Shooting When the remote controller cannot be usedReplace the batteries and press the Reset button ControllerSimple , or Auto OFF appears High sound Normal rooms Low sound Absorbing rooms LocationSpecifications FLA MCA MocpDRY CFM WET CFMPage Nombres de las piezas ContenidoMedidas de Seguridad PKA-A·GA/PKA-A·GAL Modelo montado en pared Filtro Entrada de aireRejilla Salida de aire PKA-A·FA/PKA-A·FAL Modelo montado en paredSección de pantalla Sección de controlPara controlador remoto cableado Temp ON/OFFInstalación/sustitución de pilas Para controlador remoto inalámbricoInterior InicialConfiguración de la pantalla Configuración de día de la semana y horaManejo Encendido y apagadoSelección de modo Ajuste de la temperaturaAjuste de la velocidad del ventilador Ajuste de la dirección del flujo de airePara controlador remoto cableado TemporizadorVentilación De que ya no se muestre el indicador Timer Off Cómo configurar el temporizador simpleTemporizador simple Para desactivar el temporizador semanalTemporizador de apagado automático Otras funciones Para controlador remoto inalámbricoSelección de funciones del controlador remoto Indicación de códigos de errorSelección de función Idioma ajustado inglés Ajuste detallado Tabla del indicador de puntos Mantenimiento y limpieza Localización de fallosCuando no puede utilizar el controlador remoto Refrigeración CalefacciónENCENDIDO/APAGADO VOR, EspereEspecificaciones Specifications are subject to change without notice