Mitsubishi Electronics PCA-AGA, PLA-AAA, PKA-AFAL, PKA-AGAL operation manual Detailed setting

Page 14

8. Function Selection

[Detailed setting]

[4]–1. CHANGE LANGUAGE setting

The language that appears on the dot display can be selected.

Press the [ MENU] button G to change the language.

1 English (GB), 2 German (D), 3 Spanish (E), 4 Russian (RU),

5Italian (I), 6 Chinese (CH), 7 French (F), 8 Japanese (JP) Refer to the dot display table.

[4]–2. Function limit

(1) Operation function limit setting (operation lock)

To switch the setting, press the [ ON/OFF] button D.

1 no1: Operation lock setting is made on all buttons other than the [ ON/OFF] button.

2no2: Operation lock setting is made on all buttons.

3OFF (Initial setting value): Operation lock setting is not made.

*To make the operation lock setting valid on the normal screen, it is necessary to press buttons (Press and hold down the [FILTER] and [ ON/OFF] buttons at the same time for two seconds.) on the normal screen after the above setting is made.

(2)Use of automatic mode setting

When the remote controller is connected to the unit that has automatic operation mode, the following settings can be made.

• To switch the setting, press the [ ON/OFF] button D.

1 ON (Initial setting value):

The automatic mode is displayed when the operation mode is selected.

2 OFF:

The automatic mode is not displayed when the operation mode is selected.

(3)Temperature range limit setting

After this setting is made, the temperature can be changed within the set range.

• To switch the setting, press the [ ON/OFF] button D.

1 LIMIT TEMP COOL MODE:

The temperature range can be changed on cooling/dry mode.

2 LIMIT TEMP HEAT MODE:

The temperature range can be changed on heating mode.

3LIMIT TEMP AUTO MODE:

The temperature range can be changed on automatic mode.

4 OFF (initial setting): The temperature range limit is not active.

*When the setting, other than OFF, is made, the temperature range limit setting on cooling, heating and automatic mode is made at the same time. However, the range cannot be limited when the set temperature range has not changed.

To increase or decrease the temperature, press the [ TEMP. () or ()] button F.

To switch the upper limit setting and the lower limit setting, press the [ ] button H. The selected setting will flash and the temperature can be set.

Settable range

Cooling/Dry mode:

 

Lower limit:19°C ~ 30°C,

67°F ~ 87°F

Upper limit:30°C ~ 19°C,

87°F ~ 67°F

Heating mode:

 

Lower limit:17°C ~ 28°C,

63°F ~ 83°F

Upper limit:28°C ~ 17°C,

83°F ~ 63°F

Automatic mode:

 

Lower limit:19°C ~ 28°C,

67°F ~ 83°F

Upper limit:28°C ~ 19°C,

83°F ~ 67°F

[4]–3. Mode selection setting

(1) Remote controller main/sub setting

To switch the setting, press the [ ON/OFF] button D. 1 Main: The controller will be the main controller.

2 Sub:

The controller will be the sub controller.

(2)Use of clock setting

To switch the setting, press the [ ON/OFF] button D.

1 ON:

The clock function can be used.

2OFF: The clock function cannot be used.

(3)Timer function setting

To switch the setting, press the [ ON/OFF] button D(Choose one of the followings.).

1 WEEKLY TIMER (initial setting value): The weekly timer can be used.

2AUTO OFF TIMER:

The auto off timer can be used.

3SIMPLE TIMER:

The simple timer can be used.

4TIMER MODE OFF:

The timer mode cannot be used.

*When the use of clock setting is OFF, the “WEEKLY TIMER” cannot be used.

(4)Contact number setting for error situation

• To switch the setting, press the [ ON/OFF] button D.

1 CALL OFF:

The set contact numbers are not displayed in case of error.

2 CALL **** *** ****:

The set contact numbers are displayed in case of error. CALL_:

The contact number can be set when the display is as shown on the left.

• Setting the contact numbers

To set the contact numbers, follow the following procedures.

Move the flashing cursor to set numbers. Press the [ TEMP. () and ()] button Fto move the cursor to the right (left). Press the [ CLOCK () and ()] button C to set the numbers.

[4]–4. Display change setting

(1)Temperature display °C/°F setting

To switch the setting, press the [ ON/OFF] button D.

1 °C: The temperature unit °C is used.

2 °F: The temperature unit °F is used.

(2)Suction air temperature display setting

To switch the setting, press the [ ON/OFF] button D.

1 ON:

The suction air temperature is displayed.

2 OFF:

The suction air temperature is not displayed.

(3)Automatic cooling/heating display setting

To switch the setting, press the [ ON/OFF] button D.

1 ON:

One of “Automatic cooling” and “Automatic heating” is displayed under the automatic mode is running.

2OFF:

Only “Automatic” is displayed under the automatic mode.

14

Image 14
Contents Air-Conditioners Parts Names ContentsSafety Precautions PCA-A·GA Ceiling Suspended PKA-A·GA/PKA-A·GAL Wall MountedPKA-A·FA/PKA-A·FAL Wall Mounted Operation Section Wired Remote-ControllerDisplay Section TempBattery installation/replacement Wireless Remote-ControllerOperation Screen ConfigurationSetting the Day of the Week and Time Turning ON/OFFFan speed setting Mode selectTemperature setting Airflow direction settingVentillation TimerFor Wired Remote-controller Simple Timer Timer Off indication is no longer displayedViewing the Current Simple Timer Settings Auto Off TimerTimer value is visible and appropriate Examples How to Set the Auto Off TimerFor wireless remote controller Other FunctionsFunction Selection Error Codes indicationFunction selection of remote controller Function selection flowchart Setting language EnglishDetailed setting Dot display table JapaneseTrouble Shooting Emergency Operation for Wireless Remote-controllerCare and Cleaning When the remote controller cannot be usedSimple , or Auto OFF appears Replace the batteries and press the Reset buttonController High sound Normal rooms Low sound Absorbing rooms LocationDRY CFM SpecificationsFLA MCA Mocp WET CFMPage Nombres de las piezas ContenidoMedidas de Seguridad Rejilla Salida de aire PKA-A·GA/PKA-A·GAL Modelo montado en paredFiltro Entrada de aire PKA-A·FA/PKA-A·FAL Modelo montado en paredPara controlador remoto cableado Sección de pantallaSección de control Temp ON/OFFInterior Instalación/sustitución de pilasPara controlador remoto inalámbrico InicialManejo Configuración de la pantallaConfiguración de día de la semana y hora Encendido y apagadoAjuste de la velocidad del ventilador Selección de modoAjuste de la temperatura Ajuste de la dirección del flujo de airePara controlador remoto cableado TemporizadorVentilación Temporizador simple De que ya no se muestre el indicador Timer OffCómo configurar el temporizador simple Para desactivar el temporizador semanalTemporizador de apagado automático Otras funciones Para controlador remoto inalámbricoSelección de funciones del controlador remoto Indicación de códigos de errorSelección de función Idioma ajustado inglés Ajuste detallado Tabla del indicador de puntos Cuando no puede utilizar el controlador remoto Mantenimiento y limpiezaLocalización de fallos Refrigeración CalefacciónENCENDIDO/APAGADO VOR, EspereEspecificaciones Specifications are subject to change without notice