Mitsubishi Electronics PKA-AFA Display Section, Operation Section, Wired Remote-Controller, Temp

Page 4

2. Parts Names

Wired Remote-Controller

Display Section

“Sensor” indication

For purposes of this explanation, all parts of the display are shown as lit. During actual operation, only the relevant items will be lit.

Identifies the current operation

Shows the operating mode, etc.

*Multilanguage display is sup- ported.

“CentrallyControlled”indicator

Indicates that operation of the re- mote controller has been prohib- ited by a master controller.

Day-of-Week

Shows the current day of the week.

Time/Timer Display

Shows the current time, unless the simple or Auto Off timer is set.

If the simple or Auto Off timer is set, shows the time remaining.

TIME SUN MON TUE WED THU FRI SAT

TIMER

Hr

ON

AFTER

AFTER

OFF

ERROR CODE

 

FUNCTION

˚F˚C

 

FILTER

˚F˚C

 

 

WEEKLY

ONLY1Hr.

 

SIMPLE

 

AUTO OFF

Displayed when the remote controller sensor is used.

“Locked” indicator

Indicates that remote controller but- tons have been locked.

“Clean The Filter” indicator

Comes on when it is time to clean the filter.

Timer indicators

The indicator comes on if the corre- sponding timer is set.

Fan Speed indicator

Shows the selected fan speed.

“Timer is Off” indicator

Indicates that the timer is off.

Temperature Setting

Shows the target temperature.

Up/Down Air Direction indica- tor

The indicator shows the direc- tion of the outcoming airflow.

“One Hour Only” indicator

Displayed if the airflow is set to weak and downward during COOL or DRY mode. (Operation varies according to model.)

The indicator goes off after one hour, at which time the airflow di- rection also changes.

Room Temperature display

Shows the room temperature. The room temperature display range is 8–39°C. The display flashes if the temperature is less than 8 °C or 39 °C or more.

Louver display

Indicates the action of the swing louver. Does not appear if the louver is station- ary.

(Power On indicator)

Indicates that the power is on.

Ventilation indicator

Appears when the unit is running in Ventilation mode.

Operation Section

Set Temperature buttons

Down

Up

Timer Menu button (Monitor/Set button)

Mode button (Return button)

Set Time buttons

Back

Ahead

Timer On/Off button (Set Day button)

Opening the door.

 

TEMP.

 

 

MENU

ON/OFF

BACK

MONITOR/SET

DAY

PAR-21MAA

CLOCK

 

 

ON/OFF button

 

 

Fan Speed button

 

 

Filter

button

 

 

(<Enter> button)

 

ON/OFF

Test Run button

 

 

 

 

 

Check button (Clear button)

 

FILTER

 

 

CHECK

TEST

 

OPERATION

 

Airflow Up/Down button

CLEAR

 

 

 

 

Louver button

 

 

(

Operation button)

 

 

 

To preceding operation

 

 

 

number.

Note:

 

 

 

Ventilation button

Built-in temperature sensor

(

Operation button)

To next operation number.

“PLEASE WAIT” message

This message is displayed for approximately 3 minutes when power is supplied to the indoor unit or when the unit is recovering from a power failure.

“NOT AVAILABLE” message

This message is displayed if a button is pressed to operate a function that the indoor unit does not have.

If a single remote controller is used to simultaneously operate multiple indoor units that are different models, this message will not be displayed if any of the indoor units is equipped with the function.

4

Image 4
Contents Air-Conditioners Safety Precautions ContentsParts Names PKA-A·FA/PKA-A·FAL Wall Mounted PKA-A·GA/PKA-A·GAL Wall MountedPCA-A·GA Ceiling Suspended Wired Remote-Controller Display SectionOperation Section TempBattery installation/replacement Wireless Remote-ControllerScreen Configuration Setting the Day of the Week and TimeOperation Turning ON/OFFMode select Temperature settingFan speed setting Airflow direction settingFor Wired Remote-controller TimerVentillation Simple Timer Timer Off indication is no longer displayedAuto Off Timer Timer value is visible and appropriateViewing the Current Simple Timer Settings Examples How to Set the Auto Off TimerFor wireless remote controller Other FunctionsFunction selection of remote controller Error Codes indicationFunction Selection Function selection flowchart Setting language EnglishDetailed setting Dot display table JapaneseEmergency Operation for Wireless Remote-controller Care and CleaningTrouble Shooting When the remote controller cannot be usedReplace the batteries and press the Reset button ControllerSimple , or Auto OFF appears High sound Normal rooms Low sound Absorbing rooms LocationSpecifications FLA MCA MocpDRY CFM WET CFMPage Medidas de Seguridad ContenidoNombres de las piezas PKA-A·GA/PKA-A·GAL Modelo montado en pared Filtro Entrada de aireRejilla Salida de aire PKA-A·FA/PKA-A·FAL Modelo montado en paredSección de pantalla Sección de controlPara controlador remoto cableado Temp ON/OFFInstalación/sustitución de pilas Para controlador remoto inalámbricoInterior InicialConfiguración de la pantalla Configuración de día de la semana y horaManejo Encendido y apagadoSelección de modo Ajuste de la temperaturaAjuste de la velocidad del ventilador Ajuste de la dirección del flujo de aireVentilación TemporizadorPara controlador remoto cableado De que ya no se muestre el indicador Timer Off Cómo configurar el temporizador simpleTemporizador simple Para desactivar el temporizador semanalTemporizador de apagado automático Otras funciones Para controlador remoto inalámbricoSelección de función Indicación de códigos de errorSelección de funciones del controlador remoto Idioma ajustado inglés Ajuste detallado Tabla del indicador de puntos Mantenimiento y limpieza Localización de fallosCuando no puede utilizar el controlador remoto Refrigeración CalefacciónENCENDIDO/APAGADO VOR, EspereEspecificaciones Specifications are subject to change without notice