COOL/HEAT/DRY mode operation procedure
HI POWER | ECONO |
AUTO | AM |
HI |
|
MED |
|
LO |
|
FAN SPEED ON | OFF MODE |
HI POWER TEMP ECONO
AIR FLOW
TIME CANCEL
ON OFF RESERVE
TIMER
TIMEACL
Air flow direction adjustment procedure. Page 10
NOTE
•Air is not blown out during the operation. Page 18
•The
Aim the remote control at the air conditioner.
1 |
| Press the ON/OFF button. |
2 |
| Press the MODE select button. |
| ||
| Move the [ mark] to the desirable operation position. | |
|
(Cool), (Heat), (Dry)
3 |
| Press the TEMP button. |
|
|
|
|
|
| |||||||
| Press or | button for the desired temperature. | |||||||||||||
| |||||||||||||||
|
| Standard |
|
|
|
|
|
|
|
|
|
|
| ||
|
| COOL |
| 26°C~28°C |
| HEAT |
| 22°C~24°C |
| DRY |
| 21°C~24°C |
| FAN |
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 |
| Press the FAN SPEED button | ||
| Set the air flow rate as desired. |
| ||
|
| |||
|
|
|
| |
|
| To stop: |
| Press the ON/OFF button. |
|
|
|
|
|
Program changing procedure
Set the new program.
•The operation program can also be set or changed when the air conditioner is not in operation.
Concerning high power operation
Pressing the high power button intensifies the operating power and initiates a powerful cooling or heating operation for 15 minutes continuously. The remote controller “HI POWER” illuminates but the wind capacity display is erased.
▲
NOTE
•During the high power operation, the room temperature is not con- trolled. When it causes an excessive cooling or heating, press the high power button once more to cancel the high power operation.
•High power operation is not available during the dehumidifying operation.
•During ON timer operation, HI POWER operation will start when the ON time is reached.
•When the following operations are conducted HI POWER opera- tion will be canceled.
1 When the HI POWER button is pressed again.
2 When the operation mode is changed.
3 When ECONOMY operation is conducted.
Concerning economy operation
Pressing the economy button initiates a soft operation with the power suppressed in order to avoid an excessive cooling or heating. The unit operates
1.5°C higher than the setting temperature for the weak wind capacity during cooling or 2.5°C lower than that during heating. A messageis displayed on the remote controller. The wind capacity display is erased.
NOTE
• If the economy operation is selected while operating with the strong or medium wind capacity, it takes about 1 minute before the wind capacity drops to the weak level.
– 9 –