Mitsubishi Electronics SKM22ZD-S, SKM35ZD-S Safety precautions, Installation Precautions

Page 3

Safety precautions

Before starting to use the system, please read these “Safety precautions” carefully to ensure proper operation of the system.

The safety precautions are classified as “ DANGER” and “ CAUTION”. Precautions as shown in the column “ DANGER” indicate that improper handling could have dramatic consequences like death, serious injury, etc. Nevertheless, even precautions as shown in the column “ CAUTION” might pose a serious problem, depending on the circumstances. Please observe these precautions with great care, since they are essential to your safety.

Symbols which appear frequently in the text have the following meaning:

Strictly prohibited

Observe instructions with great care

Provide positive earthing

When you have read the instruction manual, please keep it near at hand for consultation. If someone else takes over as operator, make certain that the manual is also passed on to the new operator.

INSTALLATION PRECAUTIONS

DANGER

The system is meant for domestic, residential etc. use.

The system must be installed by your dealer or a qualified pro- fessional.

If used in inferior environments, such as an engineering workplace, the equipment may function poorly.

It is not advisable to install the system yourself, as faulty handling may cause leak- age of water, electric shock or fire.

CAUTION

Do not install near places where inflammable gas may leak.

LPG

Depending on the place of installation, a circuit breaker may be necessary.

Gas leaks may cause fire.

 

If you don’t fit a circuit breaker, you may cause an electric shock.

 

 

 

 

Make sure that you drain the hose properly, so that all the water has dripped out.

Make sure that the system has been properly earthed.

Negligence may cause flooding in the room resulting in wet furniture.

Earth cables should never be connected to a gas pipe, municipal water pipe, light- ning conductor or telephone earth cable. Incorrect installation of the earth cable may produce an electric shock.

OPERATION PRECAUTIONS

DANGER

Do not expose yourself to the cooling air for prolonged peri-

 

Do not insert anything into the air inlet.

 

 

ods.

 

 

 

 

This could affect your physical condition and cause health problems.

 

This may cause injury, as the internal fan rotates at high speed.

 

 

 

 

Store the remote controller out of reach of infants.

Failure to observe this may result in the batteries being swallowed or other accidents.

– 2 –

Image 3
Contents USER’S Manual Contents Do not install near places where inflammable gas may leak Safety precautionsInstallation Precautions Operation PrecautionsPrecautions for Transfer or Repairs Do not sit on the outdoor unit nor put anything on itDo not touch the aluminum fins on the air heat exchanger Choice of operations and features CharacteristicsChoise of operations Name of each part and its function Indoor UnitOutdoor Unit SCM45ZD-S SCM80ZD-S SCM60ZD-S Unit indication section How to open the suction grillHow to close the suction grill Removal, installation of suction grillTransmission procedure Operation sectionIndication section Temperature adjustment during Auto Auto mode operation procedureCOOL/HEAT/DRY mode operation procedure Concerning high power operationConcerning economy operation Swing Flap Air flow direction adjustment procedureEmergency run operation Air scrollOFF-TIMER operation procedure Present time setting procedureProgram Timer operation procedure ON-TIMER operation procedureReplacing the batteries About Timer operationRemote control handling procedure About FAN SpeedSet a suitable room temperature Operating hintsAvoid direct sunlight and draught At the end of the season MaintenanceBefore maintenance During the operational seasonInspection and maintenance Has the unit been installed correctly?Suitable installation position Feature ColorSimultaneous Operation TroubleshootingRefrigerant oil recovery operation About the Multiple Air-conditionerPlease remember When to contact your distributor without delay Power Blackout Auto Restart FunctionAir conditioner operating conditions Page Inhalt Den Körper nicht längere Zeit dem Kühlluftstrom aussetzen Vorsichtsmassnahmen BEI DER InstallationSicherheitsvorschriften Vorsorge IM BetriebHeit kontrollieren VORSORGEMAßNAHMEN BEI Versetzung Oder ReparaturenDie Aluminiumrippen am Wärmetau Scher nicht berührenKennzeichen Unterschiedliche BetriebsartenNamen der Teile und ihre Funktionen InnengerätAussengerät SCM45ZD-S SCM80ZD-S SCM60ZD-S ON/OFF Schalter des Gerätes AnzeigenteilÖffnen des Ansaugluftgitters Schließen des AnsaugluftgittersÜbermittlung BedienungsteilAuto Betrieb Temperatureinstellung bei AutoZür Betriebsart HI Power COOL/HEAT/DRY BetriebZür Betriebsart Economy Einstellung der Luftströmungsrichtung NotbetriebMemory Flap Klappenstopp Verfahren zur Einstellung der aktuellen Zeit Betrieb des AusschalttimersEinstellung des EINSCHALTTIMER-Betriebs Betrieb des EinschalttimersBetrieb des Programm-TIMERS Die Taste Einschalttimer drückenTimer Betrieb Umgang mit der FernbedienungBatterien auswechseln Einstellung der üblichen Raum Filter regelmäßig reinigen Wenn die Fernbedienung nicht funktioniertBetriebshinweise Beim Umgang mit der Fernbedienung folgendes beachtenBei Ende der Saison WartungVor der Wartung Während der BetriebssaisonGegenstand Merkmal Farbe Ist das Gerät einwandfrei installiert?Angemessene Installation Achten Sie auf das BetriebsgeräuschAutomatischer Betrieb Zur MehrfachklimaanlageFehlersuche Gleichzeitiger BetriebBitte beachten Stromausfall-Neustartfunktion Betriebsbedingungen für die KlimaanlageEntfrostung Kennzeichen beim Heat BetriebSelbstdiagnose Mechanismen und Leistung des Heat BetriebesAIR-CONDITIONER Division AIR-CONDITIONING & Refrigeration Systems Headquarters