Mitsubishi Electronics SKM35ZD-S, SKM28ZD-S When to contact your distributor without delay

Page 20

When to contact your distributor without delay

Turn off the power switch immediately and inform your dealer in any of the following situations:

The fuse or switch blows continu- ously.

Fuse often blows.

The cable becomes extremely hot.

The covering of the cable is cracked.

CAUTION

If the power cord becomes damaged, ask your dealer or a qualified engineer to install the replacement to avoid accidents.

The TV, radio or other equipment starts to malfunction.

A switch does not activate properly.

You hear a strange noise during opera- tion.

When faulty movement is observed when the ON/OFF but- ton is pressed, even after pulling out the power plug and restarting the operation after 3 minutes, the faulty move- ment does not disappear.

3 minutes go

by, but, why ...

The RUN and TIMER lights on the unit indication section blink quickly (0.5 sec. ON; 0.5 sec. OFF) and don’t work.

Air conditioner operating conditions

Use within the following operational range. Operating outside of this range may result in the protection devices being activated, preventing the unit from working.

 

Cooling operation

Heating operation

 

 

 

Outside temperature

Approximately 21 to 43 °C

Below approximately –10 to 24 °C

Inside temperature

Approximately 21 to 32 °C

 

Below approximately 80%

 

Inside humidity

The long-term use of the unit with a humidity level

exceeding 80% may result in condensation forming on the

 

 

 

surface of the indoor unit, leading to water drips.

 

 

 

 

Power Blackout Auto Restart Function

What is power blackout auto restart function?

Power blackout auto restart function is a function that records the operational status of the air-conditioner immediately prior to it being switched off by a power cut, and then automatically resumes operations at that point after the power has been restored.

The following settings will be cancelled: 1 Timer settings

2 High-power operations

NOTE

Ther power blackout auto restart function is set at on when the air-conditioner is shipped from the factory. Consult with your dealer if this function needs to be switched off.

When power failure ocurrs, the timer setting is cancelled. Once power is resumed, reset the timer.

– 19 –

Image 20
Contents USER’S Manual Contents Safety precautions Installation PrecautionsOperation Precautions Do not install near places where inflammable gas may leakDo not touch the aluminum fins on the air heat exchanger Precautions for Transfer or RepairsDo not sit on the outdoor unit nor put anything on it Choise of operations Choice of operations and featuresCharacteristics Outdoor Unit SCM45ZD-S SCM80ZD-S SCM60ZD-S Name of each part and its functionIndoor Unit How to open the suction grill How to close the suction grillRemoval, installation of suction grill Unit indication sectionIndication section Transmission procedureOperation section Auto mode operation procedure Temperature adjustment during AutoConcerning economy operation COOL/HEAT/DRY mode operation procedureConcerning high power operation Air flow direction adjustment procedure Emergency run operationAir scroll Swing FlapPresent time setting procedure OFF-TIMER operation procedureON-TIMER operation procedure Program Timer operation procedureAbout Timer operation Remote control handling procedureAbout FAN Speed Replacing the batteriesAvoid direct sunlight and draught Set a suitable room temperatureOperating hints Maintenance Before maintenanceDuring the operational season At the end of the seasonHas the unit been installed correctly? Suitable installation positionFeature Color Inspection and maintenanceTroubleshooting Refrigerant oil recovery operationAbout the Multiple Air-conditioner Simultaneous OperationPlease remember Air conditioner operating conditions When to contact your distributor without delayPower Blackout Auto Restart Function Page Inhalt Vorsichtsmassnahmen BEI DER Installation SicherheitsvorschriftenVorsorge IM Betrieb Den Körper nicht längere Zeit dem Kühlluftstrom aussetzenVORSORGEMAßNAHMEN BEI Versetzung Oder Reparaturen Die Aluminiumrippen am WärmetauScher nicht berühren Heit kontrollierenUnterschiedliche Betriebsarten KennzeichenAussengerät SCM45ZD-S SCM80ZD-S SCM60ZD-S Namen der Teile und ihre FunktionenInnengerät Anzeigenteil Öffnen des AnsaugluftgittersSchließen des Ansaugluftgitters ON/OFF Schalter des GerätesBedienungsteil ÜbermittlungTemperatureinstellung bei Auto Auto BetriebZür Betriebsart Economy Zür Betriebsart HI PowerCOOL/HEAT/DRY Betrieb Memory Flap Klappenstopp Einstellung der LuftströmungsrichtungNotbetrieb Betrieb des Ausschalttimers Verfahren zur Einstellung der aktuellen ZeitBetrieb des Einschalttimers Betrieb des Programm-TIMERSDie Taste Einschalttimer drücken Einstellung des EINSCHALTTIMER-BetriebsBatterien auswechseln Timer BetriebUmgang mit der Fernbedienung Wenn die Fernbedienung nicht funktioniert BetriebshinweiseBeim Umgang mit der Fernbedienung folgendes beachten Einstellung der üblichen Raum Filter regelmäßig reinigenWartung Vor der WartungWährend der Betriebssaison Bei Ende der SaisonIst das Gerät einwandfrei installiert? Angemessene InstallationAchten Sie auf das Betriebsgeräusch Gegenstand Merkmal FarbeZur Mehrfachklimaanlage FehlersucheGleichzeitiger Betrieb Automatischer BetriebBitte beachten Betriebsbedingungen für die Klimaanlage Stromausfall-NeustartfunktionKennzeichen beim Heat Betrieb SelbstdiagnoseMechanismen und Leistung des Heat Betriebes EntfrostungAIR-CONDITIONING & Refrigeration Systems Headquarters AIR-CONDITIONER Division