Please remember! |
| |
You cannot restart the unit immediately after you have | Restarting has been blocked for 3 minutes after you have stopped or | |
stopped it. | ||
after switching off the power during operation, to protect the unit. | ||
| ||
(RUN light is on) |
| |
Not | Please wait for | |
operating? | ||
three minutes. | ||
| ||
| The | |
| starts up again. | |
|
| |
Air is not blown out when starting the HEATING operation. | Air flow has stopped to prevent blowing out of cold air until the indoor | |
| heat exchanger has warmed up. (2 to 5 min.) (HOT KEEP) | |
RUN light blinks slowly |
| |
(1.5 sec ON, 0.5 sec OFF) |
| |
|
| |
Air is not blown out for 5 to 10 min. at HEATING operation. | When outdoor temperature is low and humidity is high, the unit some- | |
| times performs defrosting automatically. Please wait. During defrost- | |
RUN light blinks slowly | ing, water or steam may escape from the outdoor unit. | |
(1.5 sec ON, 0.5 sec OFF) |
| |
|
| |
Air is not blown out when starting the DRY operation. | The indoor fan may stop to prevent | |
| moisture and to save energy. | |
(RUN light is on) |
| |
|
| |
Some steam escapes during COOL operation. | This may occur if the room's temperature and humidity are very high. | |
| It disappears as soon as the temperature and humidity decrease. | |
|
| |
There is a slight smell. | Air blown out during operation may smell. This is caused by tobacco | |
| or cosmetics sticking to the unit. | |
|
| |
You hear a slight gurgling sound. | This is caused by refrigerating liquid moving within the unit. |
You hear a slight cracking sound. | This is caused by heat expansion or contraction. |
|
|
After a power cut, you cannot | The memory circuit of the microcomputer has been wiped out. Use the |
stored, unless you have the power blackout auto restart function. | remote control to start the operation again. |
|
|
Remote control signals are not received. | Remote control signals may not be received if the signal receiver on |
| the air conditioner is exposed to direct sunlight or other bright light. |
| If so, cut out the sunlight or reduce the other light. |
Moisture may form on the air outlet grilles. | If the unit is operated for a long time in high humidity, moisture may |
| form on the air outlet grilles and start dripping. |
|
|
FAN operation will be performed even if COOL, DRY, or | If one unit is operating in COOL mode while another is in operating in |
HEAT have been selected. | HEAT or any other different operation mode, FAN mode operation |
| will be implemented. Individual operation modes need to be matched. |
|
|
Whistling noise is heard from the outdoor unit. | The noise means that the revolution speed is picking up on the com- |
| pressor. |
|
|
Sometimes a “Shooooo” sound might come for a short time | This is the sound when operation of another indoor unit is stopped. |
from the unit that is turned off. |
|
– 18 –