Operation and indication section for remote control

Operation section

FAN SPEED button

Each time the button is pushed, the indi- cator is switched over in turn.

HI POWER button

This button changes the HI POWER mode. Page 9

AIR FLOW button

This button changes the flap mode. When pressed, this button changes the mode in the following order:

(Air scroll)

(SWING)

Page 10

ON TIMER button

This button selects ON TIMER operation. Page 12

Clock switch

This switch for setting the clock. Page 11

OFF TIMER button

This button selects OFF TIMER operation. Page 11

HI POWER

ECONO

AUTO

AM

PM

HI

 

 

MED

 

 

LO

 

 

ON

OFF

FAN SPEED ON

OFF

MODE

HI POWER TEMP ECONO

AIR FLOW

TIME CANCEL

ON OFF RESERVE

TIMER

TIMEACL

The above illustration shows all controls, but in practice only the relevant parts are shown.

OPERATION MODE select button

Each time the button is pushed, the indi- cator is switched over in turn.

ON/OFF button

Press for starting operation, press again for stopping.

ECONOMY button

This button changes the ECONOMY mode. Page 9

TEMPERATURE button

This button sets the room temperature. (This button changes the present time and TIMER time.)

CANCEL button

This button cancels the ON timer and OFF timer.

RESERVE button

This button sets the present time and TIMER time.

RESET switch

Switch for resetting microcomputer. Page 13

Indication section

HI POWER MODE indicator

Indicates during Hi power mode operation.

TEMPERATURE Indicator

Indicates set temperature.

(Does not indicate temperature when operation mode is on AUTO)

FAN SPEED Indicator

Indicates set air flow rate with lamp.

AIR FLOW Indicator

Shows selected flap mode.

ON TIMER Indicator

Indicates during ON TIMER operation.

 

HI POWER

ECONO

AUTO

AM

PM

HI

 

 

MED

 

 

LO

 

 

 

ON

OFF

ECONOMY MODE indicator

Indicates during economy mode operation.

OPERATION MODE Indicator

Indicates selected operation with lamp.

[ (Auto) • (Cool) • (Heat) • (Dry)]

Clock Indicator

Indicates present time or timer setting time.

OFF TIMER Indicator

Indicates during OFF TIMER operation.

Transmission procedure

When each button on the remote control is pressed – with the remote control pointing towards the air conditioner unit – a signal is transmitted. When the signal is received correctly, the unit will beep.

– 7 –

Image 8
Contents USER’S Manual Contents Safety precautions Installation PrecautionsOperation Precautions Do not install near places where inflammable gas may leakDo not touch the aluminum fins on the air heat exchanger Precautions for Transfer or RepairsDo not sit on the outdoor unit nor put anything on it Choise of operations Choice of operations and featuresCharacteristics Outdoor Unit SCM45ZD-S SCM80ZD-S SCM60ZD-S Name of each part and its functionIndoor Unit How to open the suction grill How to close the suction grillRemoval, installation of suction grill Unit indication sectionIndication section Transmission procedureOperation section Auto mode operation procedure Temperature adjustment during AutoConcerning economy operation COOL/HEAT/DRY mode operation procedureConcerning high power operation Air flow direction adjustment procedure Emergency run operationAir scroll Swing FlapPresent time setting procedure OFF-TIMER operation procedureON-TIMER operation procedure Program Timer operation procedureAbout Timer operation Remote control handling procedureAbout FAN Speed Replacing the batteriesAvoid direct sunlight and draught Set a suitable room temperatureOperating hints Maintenance Before maintenanceDuring the operational season At the end of the seasonHas the unit been installed correctly? Suitable installation positionFeature Color Inspection and maintenanceTroubleshooting Refrigerant oil recovery operationAbout the Multiple Air-conditioner Simultaneous OperationPlease remember Air conditioner operating conditions When to contact your distributor without delayPower Blackout Auto Restart Function Page Inhalt Vorsichtsmassnahmen BEI DER Installation SicherheitsvorschriftenVorsorge IM Betrieb Den Körper nicht längere Zeit dem Kühlluftstrom aussetzenVORSORGEMAßNAHMEN BEI Versetzung Oder Reparaturen Die Aluminiumrippen am WärmetauScher nicht berühren Heit kontrollierenUnterschiedliche Betriebsarten KennzeichenAussengerät SCM45ZD-S SCM80ZD-S SCM60ZD-S Namen der Teile und ihre FunktionenInnengerät Anzeigenteil Öffnen des AnsaugluftgittersSchließen des Ansaugluftgitters ON/OFF Schalter des GerätesBedienungsteil ÜbermittlungTemperatureinstellung bei Auto Auto BetriebZür Betriebsart Economy Zür Betriebsart HI PowerCOOL/HEAT/DRY Betrieb Memory Flap Klappenstopp Einstellung der LuftströmungsrichtungNotbetrieb Betrieb des Ausschalttimers Verfahren zur Einstellung der aktuellen ZeitBetrieb des Einschalttimers Betrieb des Programm-TIMERSDie Taste Einschalttimer drücken Einstellung des EINSCHALTTIMER-BetriebsBatterien auswechseln Timer BetriebUmgang mit der Fernbedienung Wenn die Fernbedienung nicht funktioniert BetriebshinweiseBeim Umgang mit der Fernbedienung folgendes beachten Einstellung der üblichen Raum Filter regelmäßig reinigenWartung Vor der WartungWährend der Betriebssaison Bei Ende der SaisonIst das Gerät einwandfrei installiert? Angemessene InstallationAchten Sie auf das Betriebsgeräusch Gegenstand Merkmal FarbeZur Mehrfachklimaanlage FehlersucheGleichzeitiger Betrieb Automatischer BetriebBitte beachten Betriebsbedingungen für die Klimaanlage Stromausfall-NeustartfunktionKennzeichen beim Heat Betrieb SelbstdiagnoseMechanismen und Leistung des Heat Betriebes EntfrostungAIR-CONDITIONING & Refrigeration Systems Headquarters AIR-CONDITIONER Division