Emerson 1154, 00809-0100-4514 manual Pressure Dimension, Range Code

Page 19

Reference Manual

00809-0100-4514, Rev BA January 2008

Rosemount 1154

Figure 2-5. Transmitter Dimensional Drawings.

 

 

 

ROSEMOUNT 1154DP AND 1154HP

 

0.75 (19)

 

 

 

Clearance for

4.7 Max. (119.4)

 

 

Cover Removal

4.72 Max. (119.9)

 

(typical)

 

 

 

9 Max.

 

 

 

(228.6)

 

 

 

 

 

Nameplate

 

(remove for zero

 

and span adjust)

 

1/2–14 NPT

 

 

7/16–20

Conduit

 

Transmitter

Connection

Circuitry

UNF

(1 Place)

 

(this side)

(typical)

 

 

Terminal

 

3.7

 

 

(94)

Connections

 

 

 

(this side)

1.63

 

 

 

(41.3)

 

 

 

 

 

Welded

 

 

 

Drain/Vent Valve

 

 

 

(2) (optional 1/4

 

Dim.

3.4 (86.4)

18 NPT

 

available)

7

A

 

/16–14 UNC

 

 

 

 

(4 places)

 

 

 

 

0.8 (20) To End of Mating Tube

 

 

 

Compression Fittings (2) Swagelok

Pressure

Dimension

 

for 3/8-in. Tubing (optional 1/4–18

Range Code

A

 

NPT available)

4, 5

2.13 (54)

3

0.8

/8-in. Mating

(20)

 

 

Tubing

6, 7

2.19 (55.6)

 

DETAIL A

 

8

2.25 (57.2)

 

 

9

2.28 (57.9)

 

 

0

2.33 (59.1)

 

ROSEMOUNT 1154GP

 

 

4.7 Max. (119.4)

 

0.75 (19) Clearance

 

4.72 Max. (119.9)

 

for Cover Removal

 

 

 

 

 

 

(typical)

 

Nameplate

9 Max.

(remove for zero

and span adjust)

(228.6)

 

 

 

1/2–14 NPT

Transmitter

 

 

 

Conduit

Circuitry

 

7/16–20

 

Connection

(this side)

 

UNF

 

(1 Place)

Terminal

 

(typical)

 

 

 

3.7

 

Connections

 

 

 

 

 

(94)

 

(this side)

 

1.63

 

 

 

 

(41.3)

 

 

 

 

Low Side

 

 

 

 

Vent

 

Welded

Low Side

 

 

 

Drain/Vent

Vent

 

 

 

Valve (1)

 

 

Dim.

3.4 (86.4)

(optional 1/4–18

7/16–14 UNC

NPT available)

A

 

(4 places)

 

 

 

 

NOTE

0.8 (20) To End of Mating Tube

Dimensions are nominal in inches

 

(millimeters).

Compression Fittings (1) Swagelok for

3 8

 

/ -in.

 

Tubing (optional 1/4–18 NPT available)

 

2-7

Image 19
Contents Reference Manual RosemountImportant Notice -- Errata Rosemount 1154 Alphaline Nuclear Pressure Transmitter Return of Material Changes From June 1999 to January Revision StatusNew Old Changes Rosemount Table of Contents Specifications Reference Data Maintenance TroubleshootingSection TOC-3 TOC-4 Overview About the Transmitter Section IntroductionRosemount Overview General Considerations Section InstallationProcess Connections Mechanical ConsiderationsRosemount Electrical Considerations ConduitTransmitter Wiring Connections Procedures InstallationMechanical Range Code Pressure DimensionElectrical Liquid ServiceTransmitter Terminal Block Rosemount Section Calibration Span Adjustment Zero AdjustmentOverview Calibration Zero and Span Adjustment Calibration ProceduresZero and Span Adjustment Screws Linearity Adjustment Linearity and Damping Adjustment Damping AdjustmentRosemount Calculate zero adjustment correction in terms of pressure Rosemount Overview Transmitter Operation Section OperationΔ-Cell Demodulator Linearity AdjustmentFV Iref Overview Maintenance TroubleshootingTest Terminals Board Checkout Safety MessagesSensing Module Checkout Process Flange Removal Disassembly ProcedurePart Description Rosemount 1154 Parts ListReassembly Procedure Rosemount Process Flange Reassembly Symptom Potential Source Corrective Action Post Assembly TestsOn Next Check for adequate voltage to the transmitter Nuclear Specifications Specifications and Reference DataPerformance Specifications Range Code Overpressure Effect Range Code Static Pressure Zero Effect Functional SpecificationsRange Code Response Time 25 to 0-150 inH2O 0-6.22 to 0-37.3 kPa Range Code Pressure RangesRange Code Overpressure Limit Physical SpecificationsRosemount Ordering Information Rosemount 1154DP 1154HP 1154GP Part Description Order No Rosemount 1154DP, 1154HP, and 1154GP Spare PartsFor use with existing N0026 transmitter only Spare Parts Shelf Life Important Notice Rosemount Current Control Current Limit Index-2 Page ¢00809-XXXX-XXXX ¤