Page 21
Reference Manual
00809-0100-4514,
Rev BA January 2008
Rosemount 1154
Figure
2-7.
Transmitter Terminal Block.
Signal Terminals
Test Terminals
2-9
Page 20
Page 22
Image 21
Page 20
Page 22
Contents
Reference Manual
Rosemount
Important Notice -- Errata
Rosemount 1154 Alphaline Nuclear Pressure Transmitter
Return of Material
Revision Status
Changes From June 1999 to January
New Old Changes
Rosemount
Table of Contents
Maintenance Troubleshooting
Specifications Reference Data
Section
TOC-3
TOC-4
Overview About the Transmitter
Section Introduction
Rosemount
Overview General Considerations
Section Installation
Process Connections
Mechanical Considerations
Rosemount
Electrical Considerations
Conduit
Transmitter Wiring Connections
Installation
Procedures
Mechanical
Range Code
Pressure Dimension
Electrical
Liquid Service
Transmitter Terminal Block
Rosemount
Span Adjustment Zero Adjustment
Section Calibration
Overview Calibration
Zero and Span Adjustment
Calibration Procedures
Zero and Span Adjustment Screws
Linearity Adjustment
Linearity and Damping Adjustment
Damping Adjustment
Rosemount
Calculate zero adjustment correction in terms of pressure
Rosemount
Overview Transmitter Operation
Section Operation
Δ-Cell
Demodulator
Linearity Adjustment
FV Iref
Overview
Maintenance Troubleshooting
Test Terminals Board Checkout
Safety Messages
Sensing Module Checkout
Process Flange Removal
Disassembly Procedure
Part Description
Rosemount 1154 Parts List
Reassembly Procedure
Rosemount
Process Flange Reassembly
Post Assembly Tests
Symptom Potential Source Corrective Action
On Next
Check for adequate voltage to the transmitter
Nuclear Specifications
Specifications and Reference Data
Performance Specifications
Range Code Overpressure Effect
Functional Specifications
Range Code Static Pressure Zero Effect
Range Code Response Time
25 to 0-150 inH2O 0-6.22 to 0-37.3 kPa
Range Code Pressure Ranges
Range Code Overpressure Limit
Physical Specifications
Rosemount
Ordering Information
Rosemount 1154DP 1154HP 1154GP Part Description Order No
Rosemount 1154DP, 1154HP, and 1154GP Spare Parts
For use with existing N0026 transmitter only
Spare Parts Shelf Life Important Notice
Rosemount
Current Control Current Limit
Index-2
Page
¢00809-XXXX-XXXX ¤
Related pages
Troubleshooting for Inter-Tel PATL41106.0
Specification s for Moen 74998
Index of Error Messages for Acer 8531
Circuit Diagram for Yamaha Electric Guitar AES FG
Aged When the Power is Turned on for Gold's Gym GGTL39608.0
Installing the Vacuum BAG for Homelite UT08542A
Parts List for Invacare 6358E
Code list for USA Market for Toshiba HDD-J35
Connecting for HP de100c
What tools do I need for maintenance on the Hydro Gear 314-0510?
Find out more
Top
Page
Image
Contents