Reference Manual
Rosemount 1154
POST ASSEMBLY TESTS
1.Conduct hydrostatic testing to 150% of maximum working pressure or 2,000 psi, whichever is greater.
2.Calibrate the transmitter per the calibration section of this manual.
3.Conduct nuclear cleaning to 1 ppm chloride content of transmitter “wetted parts.”
Table
ITEM(S) TO BE TORQUED | TORQUE VALUE | TOLERANCE |
|
|
|
Bracket to Mounting Panel Bolts | 19 | ±1 |
|
|
|
Transmitter to Bracket Bolts | 21 | ±1 |
|
|
|
Swagelok Process Fittings | See Installation Instructions | — |
|
|
|
Drain/Vent Valves | 7.5 | ±0.5 |
|
|
|
Covers | 16.5 | ±1 |
|
|
|
Module Neck Lock Nut | 35 | ±1 |
|
|
|
Conduit Fitting | 4 to 7 turns or a minimum of 12.5 | ±1 |
|
| |
|
|
|
Flange Bolts | See Process Flange Reassembly | — |
|
|
|
Terminal Block Screws | 5 | ±1 |
|
|
|
Amplifier Board Screws | Nominal 10 | — |
|
|
|
Table 5-3. Troubleshooting.
Symptom | Potential Source | Corrective Action |
|
|
|
High Output | Primary Element | Check for restrictions at primary element, improper installation or poor condition. Note any |
|
| changes in process fluid properties that may affect output. |
|
|
|
| Impulse Piping | Check for leaks or blockage. |
|
| Ensure blocking locking valves are fully open. |
|
| Check for entrapped gas in liquid lines, or liquid in dry lines. |
|
| Ensure that density of fluid in impulse line is unchanged. |
|
| Check for sediment in transmitter process flanges. |
|
|
|
| Transmitter | Make sure that post connectors and the sensor connections are clean. If the electronics are |
| Electronics | still suspect, substitute new electronics. |
|
|
|
| Transmitter | Determine faulty circuit board by trying spare boards. Replace faulty circuit board. |
| Electronics Failure |
|
|
|
|
| Sensing Module | See Sensing Module Checkout section. The sensing element is not field repairable and must |
|
| be replaced if found to be defective. See “Disassembly Procedure” for instructions on |
|
| disassembly. Check for obvious defects, such as a punctured isolating diaphragm or fill fluid |
|
| loss, and contact Rosemount Nuclear Instruments, Inc. at (952) |
|
|
|
| Power Supply | Check the power supply output voltage at the transmitter. |
|
|
|
|
| Continued on Next Page |
|
|
|
|
|
|