ORDERING INFORMATION

 

Table 6-1. Transmitter Design Specifications.

 

 

 

 

 

 

Model

Description

 

 

 

 

 

 

 

1154

Alphaline Pressure Transmitters for Nuclear Applications, IEEE Std 323-1974 and IEEE Std 344-1975

 

 

 

 

 

Code

Pressure Measurement

 

 

 

 

 

 

 

DP

Differential Pressure, 2,000 psig (13.8 MPa) Static Pressure Rating

 

HP

Differential Pressure, 3,000 psig (20.68 MPa) Static Pressure Rating

 

GP

Gage Pressure

 

 

 

 

 

 

 

 

 

 

 

PRESSURE RANGES at 68 °F

 

 

Rosemount 1154DP

 

Rosemount 1154HP

Rosemount 1154GP

Code

(Differential)

 

(Differential)

(Gage)

 

 

 

 

 

4

0–25 to 0–150 inH2O

 

0–25 to 0–150 inH2O

0–25 to 0–150 inH2O

 

(0–6.22 to 0–37.3 kPa)

 

(0–6.22 to 0–37.3 kPa)

(0–6.22 to 0–37.3 kPa)

 

 

 

 

 

5

0–125 to 0–750 inH2O

 

0–125 to 0–750 inH2O

0–125 to 0–750 inH2O

 

(0–31.08 to 0–186.4 kPa)

 

(0–31.08 to 0–186.4 kPa)

(0–31.08 to 0–186.4 kPa)

 

 

 

 

 

6

0–17 to 0–100 psi

 

0–17 to 0–100 psi

0–17 to 0–100 psi

 

(0–0.12 to 0–0.69 MPa)

 

(0–0.12 to 0–0.69 MPa)

(0–0.12 to 0–0.69 MPa)

 

 

 

 

 

7

0–50 to 0–300 psi

 

0–50 to 0–300 psi

0–50 to 0–300 psi

 

(0–0.34 to 0–2.07 MPa)

 

(0–0.34 to 0–2.07 MPa)

(0–0.34 to 0–2.07 MPa)

 

 

 

 

 

8

0–170 to 0–1,000 psi

 

0–170 to 0–1,000 psi

 

(0–1.17 to 0–6.89 MPa)

 

 

(0–1.17 to 0–6.89 MPa)

 

 

 

 

 

9

 

0–500 to 0–3,000 psi

 

 

 

 

(0–3.45 to 0–20.68 MPa)

 

 

 

 

 

0

 

0–1,000 to 0–4,000 psi

 

 

 

 

(0–6.89 to 0–27.56 MPa)

 

 

 

 

 

Code

Output

 

 

 

 

 

 

 

 

R(1)

Standard 4–20 mA

 

 

 

Code

Flange Option

 

 

 

 

 

 

 

A

Welded 3/8 in. Swagelok Compression Fitting Process Connection and Welded Drain/Vent Valve

B(2)

¼–18 NPT Process Connection and Welded Drain/Vent Valve

 

C(2)

¼–18 NPT Process Connection and Drain Hole (Drain/Vent Valve not supplied)

 

D

One Flange Code Option A and One Remote Seal

 

E(2)

One Flange Code Option B and One Remote Seal

 

F(2)

One Flange Code Option C and One Remote Seal

 

G

Two Remote Seals

 

 

 

H

Welded 3/8 in. Swagelok Compression Fittings on Both Process Connection and Drain/Vent Connection

J(2)

Welded 3/8 in. Swagelok Compression Fitting Process Connection and ¼–18 NPT Drain Hole

L

One Flange Code Option H and One Remote Seal

 

M(2)

One Flange Code Option J and One Remote Seal

 

Typical Model Number:1154 DP 4 R A

 

 

 

 

 

 

 

 

(1)The Rosemount 1154 with Output Code R Electronics is also available with adjustable damping. This option is specified by appending “N0037” to the end of the complete model number, for example, 1154DP4RAN0037.

(2)Note: Customer assumes responsibility for qualifying connection interfaces on these options. Contact Rosemount Nuclear Instruments, Inc. for details.

6-8

Image 52
Contents Rosemount Reference ManualImportant Notice -- Errata Rosemount 1154 Alphaline Nuclear Pressure Transmitter Return of Material Changes From June 1999 to January Revision StatusNew Old Changes Rosemount Table of Contents Specifications Reference Data Maintenance TroubleshootingSection TOC-3 TOC-4 Section Introduction Overview About the TransmitterRosemount Section Installation Overview General ConsiderationsMechanical Considerations Process ConnectionsRosemount Conduit Electrical ConsiderationsTransmitter Wiring Connections Procedures InstallationMechanical Pressure Dimension Range CodeLiquid Service ElectricalTransmitter Terminal Block Rosemount Section Calibration Span Adjustment Zero AdjustmentOverview Calibration Calibration Procedures Zero and Span AdjustmentZero and Span Adjustment Screws Linearity Adjustment Damping Adjustment Linearity and Damping AdjustmentRosemount Calculate zero adjustment correction in terms of pressure Rosemount Section Operation Overview Transmitter OperationΔ-Cell Linearity Adjustment DemodulatorFV Iref Maintenance Troubleshooting OverviewSafety Messages Test Terminals Board CheckoutSensing Module Checkout Disassembly Procedure Process Flange RemovalRosemount 1154 Parts List Part DescriptionReassembly Procedure Rosemount Process Flange Reassembly Symptom Potential Source Corrective Action Post Assembly TestsOn Next Check for adequate voltage to the transmitter Specifications and Reference Data Nuclear SpecificationsPerformance Specifications Range Code Overpressure Effect Range Code Static Pressure Zero Effect Functional SpecificationsRange Code Response Time Range Code Pressure Ranges 25 to 0-150 inH2O 0-6.22 to 0-37.3 kPaPhysical Specifications Range Code Overpressure LimitRosemount Ordering Information Rosemount 1154DP, 1154HP, and 1154GP Spare Parts Rosemount 1154DP 1154HP 1154GP Part Description Order NoFor use with existing N0026 transmitter only Spare Parts Shelf Life Important Notice Rosemount Current Control Current Limit Index-2 Page ¢00809-XXXX-XXXX ¤