Emerson IFT9701 instruction manual Mounting the transmitter to a wall or other surface

Page 21

Remotely Mounting the Transmitter continued

Figure 3-2 Mounting the transmitter to a wall or other surface

Circuit board compartment

User access not normally required

Area approvals tag

Field wiring compartment

Sensor wiring compartment

4X M8 bolt

4X lock washer

4X flat washer

To rotate transmitter: remove, then re-install to 12 ft-lb (16 N-m) torque

4X 5/16 (M8) bolt

User-supplied

Figure 3-3 Mounting the transmitter to an instrument pole

Area approvals tag

Field wiring compartment

Sensor wiring compartment

4X 5/16 (M8) bolt

User-supplied

4X M8 bolt

4X lock washer

4X flat washer

To rotate transmitter: remove, then re-install to 12 ft-lb (16 N-m) torque

Circuit board compartment

User access not normally required

2X 5/16-inch (M8) U-bolt for 2-inch pipe

User-supplied

Before You Begin

Getting Started

Mounting the Remote Transmitter

Power Supply and Output Wiring

Model IFT9701 Transmitter Instruction Manual

13

Image 21
Contents Micro Motion Page Micro Motion Page Contents Flowmeter Startup Index Page Before You Begin About this manual SafetyEuropean installations DefinitionsFlowmeter components Remotely mounted IFT9701 transmitter Page Safety, reliability, accessibility Getting StartedHazardous area Orientation and mounting Temperature, humidity, and vibrationTransmitters approved for Atex Zone Visibility of tagsCompartment tags and lockout device Jumper settingsSecurity Fault output levelsRe-installing the circuit board compartment cover Remotely Mounting the Transmitter Installation dimensions for remote mounting Mounting the transmitter to a wall or other surface Cable types Connecting the transmitter to the sensorCable selection guidelines Temperature ranges for jacket materialWiring connections to sensor Guidelines for conduitGuidelines for cable gland Sensor terminal designations Cable connections to sensorsSensor wiring compartment and sensor wiring terminals Wiring guidelines Power Supply and Output WiringPower supply wiring terminals Connect power supply wiringConnect output wiring Wire guidelines for DC power supplyMilliamp output performance Milliamp outputMilliamp output connected to Bell 202 multidrop network Typical Hart network wiringHart Communicator connections Communication tools connected to milliamp outputPulse output Wiring to pulse counter with internal pull-up resistor Wiring to Series 3000 applications platform with I/O cable Page Startup procedures Customer serviceFlowmeter Startup ZeroingStartup mode Diagnostic LEDOperating mode InitializationFlowmeter zeroing Zeroing procedureDiagnosing zero failure Configuration, calibration, and characterizationProcess measurement Page Configuration overview Configuration with a Hart CommunicatorConfiguration parameters Hart tagMeasurement units Mass flow unit Software label Volume flow unit Measurement units for mass and volume flowDamping Flow cutoffEffect of flow direction on outputs and totalizers Flow directionPulse output scaling Range values for milliamp outputAuto zero Calibration proceduresDiagnosing zeroing failure Flow calibration procedureTotal Characterization Configuration with ProLink II Software Configuration window Device panel Process variable measurement Configuration window Flow panelMass flow unit Software label Volume flow unit Effect of flow direction on outputs and totalizers Configuration window Analog Output panel Output configurationConfiguration window Frequency panel Configuration with ProLink II Software Flow Calibration dialog box Diagnosing zeroing failure Totalizer Control window Characterization Configuration window Density panel Troubleshooting Transmitter diagnostic toolsGeneral guidelines Fault outputs Optional LCDNormal conditions indicated by LED Conditions indicated by optional LCD Power supplyWiring Power supply connectionsOver range and sensor failure conditions Normal resistance and voltage ranges for flowmeter circuitsSlug flow Troubleshooting over range and sensor failure conditionsTransmitter failure Digital diagnostic messagesPage Performance specifications IFT9701 SpecificationsFunctional specifications Output signals Milliamp active Pulse passiveOutput testing Current source Fault indicationPower supply options 85 to 250 VAC Local display optionalProcess fluid vs. ambient temperature Environmental limits Temperature Operating20 to 30 VDC StorageHumidity limits Vibration limitsDensity limits Shipping weight Ambient temperature effect on milliamp outputEnvironmental effects Hazardous area classificationsPage Hart Communicator Menu Trees Appendix BHart Communicator Menu Trees Appendix C Installing the Optional DisplayInstalling the Optional Display Return Policy New and unused equipmentUsed equipment Page Atex IndexHart Customer service Index Page 3100572