Emerson IFT9701 instruction manual Humidity limits, Vibration limits, Density limits

Page 76

IFT9701 Specifications continued

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150

 

 

Maximum, with no

 

 

 

 

 

 

 

 

140

 

 

 

 

 

 

 

 

 

ambient temperature, °F

 

 

external heat source

 

 

 

 

 

 

Expected maximum

130

 

 

 

 

 

 

 

 

 

 

 

 

120

 

 

 

 

 

 

 

 

 

 

 

 

110

Maximum, when mounted

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

in direct sunlight

 

 

 

 

 

 

 

90

 

 

 

 

 

 

 

 

 

 

 

 

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

158

167

176

185

194

203

212

221

230

239

248

257

266

Process fluid temperature, °F

 

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

ambient temperature, °C

55

 

 

 

Maximum, with no

 

 

 

 

 

Expected maximum

 

 

 

 

 

 

 

 

 

50

 

 

 

external heat source

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

 

 

 

 

 

 

 

 

 

 

 

40

Maximum, when mounted

 

 

 

 

 

 

 

 

in direct sunlight

 

 

 

 

 

 

 

35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70

75

80

85

90

95

100

105

110

115

120

125

130

Process fluid temperature, °C

A.3.3 Humidity limits

5 to 95% non-condensing

A.3.4 Vibration limits

Meets IEC 68.2.6, 2 g, endurance sweep, 10 to 2000 Hz, 50 sweep cycles

A.4 Density limits

0.2 to 2.0 g/cc (200 to 2000 kg/m3) for volume flow

0.0 to 2.0 g/cc (0 to 2000 kg/m3) for mass flow

68

Model IFT9701 Transmitter Instruction Manual

Image 76
Contents Micro Motion Page Micro Motion Page Contents Flowmeter Startup Index Page About this manual Safety Before You BeginDefinitions European installationsFlowmeter components Remotely mounted IFT9701 transmitter Page Getting Started Safety, reliability, accessibilityHazardous area Temperature, humidity, and vibration Orientation and mountingVisibility of tags Transmitters approved for Atex ZoneJumper settings Compartment tags and lockout deviceFault output levels SecurityRe-installing the circuit board compartment cover Remotely Mounting the Transmitter Installation dimensions for remote mounting Mounting the transmitter to a wall or other surface Connecting the transmitter to the sensor Cable typesTemperature ranges for jacket material Cable selection guidelinesGuidelines for conduit Wiring connections to sensorGuidelines for cable gland Cable connections to sensors Sensor terminal designationsSensor wiring compartment and sensor wiring terminals Power Supply and Output Wiring Wiring guidelinesConnect power supply wiring Power supply wiring terminalsWire guidelines for DC power supply Connect output wiringMilliamp output Milliamp output performanceTypical Hart network wiring Milliamp output connected to Bell 202 multidrop networkCommunication tools connected to milliamp output Hart Communicator connectionsPulse output Wiring to pulse counter with internal pull-up resistor Wiring to Series 3000 applications platform with I/O cable Page Customer service Startup proceduresFlowmeter Startup ZeroingDiagnostic LED Startup modeOperating mode InitializationZeroing procedure Flowmeter zeroingConfiguration, calibration, and characterization Diagnosing zero failureProcess measurement Page Configuration with a Hart Communicator Configuration overviewHart tag Configuration parametersMeasurement units Measurement units for mass and volume flow Mass flow unit Software label Volume flow unitFlow cutoff DampingFlow direction Effect of flow direction on outputs and totalizersRange values for milliamp output Pulse output scalingCalibration procedures Auto zeroFlow calibration procedure Diagnosing zeroing failureTotal Characterization Configuration with ProLink II Software Configuration window Device panel Configuration window Flow panel Process variable measurementMass flow unit Software label Volume flow unit Effect of flow direction on outputs and totalizers Output configuration Configuration window Analog Output panelConfiguration window Frequency panel Configuration with ProLink II Software Flow Calibration dialog box Diagnosing zeroing failure Totalizer Control window Characterization Configuration window Density panel Transmitter diagnostic tools TroubleshootingGeneral guidelines Optional LCD Fault outputsNormal conditions indicated by LED Power supply Conditions indicated by optional LCDPower supply connections WiringNormal resistance and voltage ranges for flowmeter circuits Over range and sensor failure conditionsTroubleshooting over range and sensor failure conditions Slug flowDigital diagnostic messages Transmitter failurePage IFT9701 Specifications Performance specificationsFunctional specifications Output signals Milliamp active Pulse passiveFault indication Output testing Current sourcePower supply options 85 to 250 VAC Local display optionalEnvironmental limits Temperature Operating Process fluid vs. ambient temperature20 to 30 VDC StorageVibration limits Humidity limitsDensity limits Ambient temperature effect on milliamp output Shipping weightEnvironmental effects Hazardous area classificationsPage Appendix B Hart Communicator Menu TreesHart Communicator Menu Trees Installing the Optional Display Appendix CInstalling the Optional Display New and unused equipment Return PolicyUsed equipment Page Index AtexHart Customer service Index Page 3100572