ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS
(and Optional Electric or Gas Cooktop Combination)
For typical under counter installation of an electric
Only certain cooktop models may be installed over certain
Cabinet side filler panels are necessary to isolate the unit from adjoining cabinets. Cabinet side filler height should allow for installation of approved cooktop models
To reduce the risk of personal injury and tipping of the wall oven, the wall oven must be secured to the cabinet (s) by mounting brackets.
208/240 Volt junction box for
Approx. 3” (7.5 cm)
G
36” Min.
(91.4 cm) Min.
H
F
Use 3/4” (1.9 cm) plywood, installed on two runners, flush with toe plate. Base must be capable of supporting 150 pounds (68 kg) for 27" models and 200 pounds (90 kg) for 30" models.
Cut an opening in wood base minimum 9” x 9” (23 X 23 cm), 2” (5 cm) from left side filler panel, to route armoured cable to junction box.
4 1/2” (11.5 cm) Max.*
*If no cooktop is installed directly over the oven unit, 5” (12.7 cm) maximum is allowed above the floor.
CUTOUT DIMENSIONS
| F.WIDTH | G.DEPTH | H.HEIGHT | |
|
|
|
| |
27" (68.6 cm) | 247/8" (63.2 cm) Min. | 23½" (59.7 cm) Min. | 27¼" (69.2 cm) Min. | |
Wall Oven | 25¼" (64.1 cm) Max. | 28¼" (71.8 cm) Max. | ||
| ||||
|
|
|
| |
30" (76.2 cm) | 28½" (72.4 cm) Min. | 23½" (59.7 cm) Min. | 27¼" (69.2 cm) Min. | |
Wall Oven | 29" (73.7 cm) Max. | 28¼" (71.8 cm) Max. | ||
| ||||
|
|
|
|
Figure 8- TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT-IN OVEN
WITH AN ELECTRIC COOKTOP MOUNTED ABOVE
7