6.Complete installation following instructions for your type of electrical connection:
Electrical Connection Options
If your home has: | And you will be | Go to Section: |
| connecting to: |
|
A UL listed, | ||
(NEMA type | Power supply cord | |
| minimum, |
|
|
| |
| power supply |
|
| cord |
|
A fused | ||
| disconnect or | Direct wire |
| circuit breaker |
|
5" | box |
|
(12.7 cm) |
|
|
A UL listed, | ||
(NEMA type | Power supply cord | |
| minimum, |
|
|
| |
| power supply |
|
| cord |
|
A fused | ||
1" | disconnect or | Direct wire |
circuit breaker |
| |
(2.5 cm) |
| |
| box |
|
3" |
|
|
(7.6 cm) |
|
|
4-wire connection: Power Supply Cord
Use this method for:
■New
■Mobile homes
■Recreational vehicles
■In an area where local codes prohibit grounding through the neutral
1.Part of metal ground strap must be cut out and removed.
A
B
C
A. Metal ground strap
B.Discard
C.
2.Use Phillips screwdriver to remove the
3.Feed the power supply cord through the strain relief in the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.
A
B
C
D
A. Terminal block
B.
C.Cord/conduit plate
D.Power supply cord wires
4.Use Phillips screwdriver to connect the green ground wire from the power supply cord to the range with the
5.Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of the
A | F |
| |
| B |
C | E |
| |
| D |
A. | D. Green ground wire |
B. | E. Neutral (center) wire |
C. Line 1 (black) | F. Line 2 (red) |
6.Connect line 1 (black) and line 2 (red) wires to the outer terminal block posts with
7.Securely tighten hex nuts.
NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening, with ring terminals and marked for use with ranges.
8.Replace terminal block access cover.
11