KitchenAid W10526086A Moving the Range, For power supply cord-connected ranges

Page 20

4.Apply masking tape to the end of a ⁹⁄₃₂" (7.0 mm) nut driver to help hold the LP gas orifice spud in the nut driver while changing it. Press nut driver down onto the LP gas orifice spud and remove by turning it counterclockwise and lifting out. Set the LP gas orifice spud aside.

A

A. LP gas orifice spud

Use the following chart for correct Natural gas orifice spud for each burner. Refer to the model/serial rating plate behind the control panel for proper sizing of Natural orifice spuds for each burner location.

Natural Gas Orifice Spud Chart

Burner Rating

Color

Number

5,000 BTU

Green

107N

7,300 BTU

Yellow

125N

9,200 BTU

Orange

142N

10,000 BTU

Transparent

149N

15,000 BTU

White

180N

16,000 BTU

Black

195N

 

 

 

5.Replace the LP gas orifice spud with correct Natural gas orifice spud. See the “Natural Gas Orifice Spud Chart.”

6.Replace burner base and hand tighten the screws.

7.Replace burner cap.

8.Repeat steps 1 through 7 for the remaining burners.

9.Place LP gas orifice spuds in plastic parts bag for future use and keep with literature package.

10.Replace burner grates.

11.Complete installation. See “Make Gas Connection” and Electronic Ignition System” sections.

Checking for proper cooktop burner flame is very important. The small inner cone should have a very distinct blue flame ¼" to ½" long. The outer cone is not as distinct as the inner cone. Natural gas flames do not have yellow tips.

IMPORTANT: You may have to adjust the low setting for each cooktop burner.

Moving the Range

WARNING

Tip Over Hazard

A child or adult can tip the range and be killed.

Install anti-tip bracket to floor or wall per installation instructions.

Slide range back so rear range foot is engaged in the slot of the anti-tip bracket.

Re-engage anti-tip bracket if range is moved.

Do not operate range without anti-tip bracket installed and engaged.

Failure to follow these instructions can result in death or serious burns to children and adults.

When moving range, slide range onto cardboard or hardboard to avoid damaging the floor covering.

If removing the range is necessary for cleaning or maintenance:

For power supply cord-connected ranges:

1.Slide range forward.

2.Turn manual shutoff valve to the closed position.

3.Unplug the power supply cord.

4.Disconnect the gas supply tubing.

5.Complete cleaning or maintenance.

6.Reconnect the gas supply tubing.

7.Open the manual shutoff valve in the gas supply line.

8.Plug in power supply cord.

9.Slide range back so rear range foot is under anti-tip bracket.

10.Refer to the “Verify Anti-Tip Bracket Is Installed and Engaged” section to verify engagement.

11.Check that range is level.

20

Image 20
Contents Table des matières Range Safety Your safety and the safety of others are very importantInstallation Requirements Tools and PartsTools needed Parts suppliedProduct Dimensions Mobile Home Additional Installation RequirementsCabinet Dimensions Mobile home installations requireElectrical Requirements U.S.A. Only Electrical ConnectionElectrical Requirements Canada Only If connecting to a 4-wire systemIf connecting to a 3-wire system Gas Supply Requirements Type of GasGas Supply Line Gas Pressure RegulatorInstallation Instructions Adjust Leveling LegsInstall Anti-Tip Bracket Unpack RangePower Supply Cord Direct WireElectrical Connection U.S.A. Only Floor Mounting Wall MountingStyle 1 Power supply cord strain relief Style 2 Direct wire strain reliefWire connection Power Supply Cord Wire Connection Direct Wire Bare Wire Torque Specifications Wire Awg TorqueMake Gas Connection Typical flexible connectionComplete connection Verify Anti-Tip Bracket Is Installed EngagedLevel Range Complete Installation Electronic Ignition SystemTo Convert Gas Pressure Regulator GAS ConversionsLP Gas Conversion LP Gas Orifice Spud Chart Burner Rating Color Number To Convert Surface BurnersNatural Gas Conversion Moving the Range For power supply cord-connected rangesNatural Gas Orifice Spud Chart Burner Rating Color Number For direct-wired ranges Sécurité DE LA Cuisinière Votre sécurité et celle des autres est très importanteExigences D’INSTALLATION Outils et composantsPièces fournies Outils nécessairesExigences demplacement Dimensions du produitPièces nécessaires Utilisation d’un cordon d’alimentation électriqueDimensions du placard Spécifications électriquesCanalisation de gaz Spécifications de l’alimentation en gazType de gaz Instructions Dinstallation Déballage de la cuisinièreDétendeur de gaz Débit thermique des brûleursMontage au plancher Montage au mur Installation de la bride antibasculementRéglage des pieds de nivellement Terminer le raccordement Raccordement au gazRaccordement typique par raccord flexible Brûleurs de surface à commande tactile sur certains modèles Réglage de laplomb de la cuisinièreSystème dallumage électronique Allumage initial et réglages des flammesAchever linstallation Si vous avez besoin d’assistance ou de serviceRéglage de la taille des flammes Réglage des brûleurs standardConversions DE GAZ Conversion pour lalimentation au gaz PropaneConversion du détendeur Conversion des brûleurs de surfaceConversion pour lalimentation au gaz Naturel Déplacement de la cuisinière Page Page Page Page W10526086A