4.Apply masking tape to the end of a ⁹⁄₃₂" (7.0 mm) nut driver to help hold the LP gas orifice spud in the nut driver while changing it. Press nut driver down onto the LP gas orifice spud and remove by turning it counterclockwise and lifting out. Set the LP gas orifice spud aside.
A
A. LP gas orifice spud
Use the following chart for correct Natural gas orifice spud for each burner. Refer to the model/serial rating plate behind the control panel for proper sizing of Natural orifice spuds for each burner location.
Natural Gas Orifice Spud Chart
Burner Rating | Color | Number |
5,000 BTU | Green | 107N |
7,300 BTU | Yellow | 125N |
9,200 BTU | Orange | 142N |
10,000 BTU | Transparent | 149N |
15,000 BTU | White | 180N |
16,000 BTU | Black | 195N |
|
|
|
5.Replace the LP gas orifice spud with correct Natural gas orifice spud. See the “Natural Gas Orifice Spud Chart.”
6.Replace burner base and hand tighten the screws.
7.Replace burner cap.
8.Repeat steps 1 through 7 for the remaining burners.
9.Place LP gas orifice spuds in plastic parts bag for future use and keep with literature package.
10.Replace burner grates.
11.Complete installation. See “Make Gas Connection” and Electronic Ignition System” sections.
Checking for proper cooktop burner flame is very important. The small inner cone should have a very distinct blue flame ¼" to ½" long. The outer cone is not as distinct as the inner cone. Natural gas flames do not have yellow tips.
IMPORTANT: You may have to adjust the low setting for each cooktop burner.
Moving the Range
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install
Slide range back so rear range foot is engaged in the slot of the
Do not operate range without
Failure to follow these instructions can result in death or serious burns to children and adults.
When moving range, slide range onto cardboard or hardboard to avoid damaging the floor covering.
If removing the range is necessary for cleaning or maintenance:
For power supply cord-connected ranges:
1.Slide range forward.
2.Turn manual shutoff valve to the closed position.
3.Unplug the power supply cord.
4.Disconnect the gas supply tubing.
5.Complete cleaning or maintenance.
6.Reconnect the gas supply tubing.
7.Open the manual shutoff valve in the gas supply line.
8.Plug in power supply cord.
9.Slide range back so rear range foot is under
10.Refer to the “Verify
11.Check that range is level.
20