KitchenAid W10526086A Gas Supply Requirements, Type of Gas, Gas Supply Line

Page 7

Gas Supply Requirements

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

Observe all governing codes and ordinances.

IMPORTANT: This installation must conform with all local codes and ordinances. In the absence of local codes, installation must conform with American National Standard, National Fuel Gas Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest edition.

IMPORTANT: Leak testing of the range must be conducted according to the manufacturer’s instructions.

Type of Gas

Natural gas:

This range is design-certified by CSA International for use with Natural gas or, after proper conversion, for use with LP gas.

This range is factory set for use with Natural gas. See “Gas Conversions” section. The model/serial rating plate located behind the control panel has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier.

LP gas conversion:

Conversion must be done by a qualified service technician.

No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. See “Gas Conversions” section.

Gas Supply Line

Provide a gas supply line of ¾" (1.9 cm) rigid pipe to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. With LP gas, piping or tubing size can be ½" (1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system.

NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape.

Flexible metal appliance connector:

If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to 152.4 cm) long, ½" (1.3 cm) or

¾" (1.9 cm) I.D., flexible metal appliance connector may be used for connecting range to the gas supply line.

A ½" (1.3 cm) male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator.

Do not kink or damage the flexible metal tubing when moving the range.

Rigid pipe connection:

The rigid pipe connection requires a combination of pipe fittings to obtain an in-line connection to the range. The rigid pipe must be level with the range connection. All strains must be removed from the supply and fuel lines so range will be level and in line.

Must include a shutoff valve:

The supply line must be equipped with a manual shutoff valve. This valve should be located in the same room but external to the range opening, such as an adjacent cabinet. It should be in a location that allows ease of opening and closing. Do not block access to shutoff valve. The valve is for turning on or shutting off gas to the range.

B

A

C

A. Gas supply line

B. Shutoff valve “open” position

C. To range

Gas Pressure Regulator

The gas pressure regulator supplied with this range must be used. The inlet pressure to the regulator should be as follows for proper operation:

Natural gas:

Minimum pressure: 5" WCP

Maximum pressure: 14" WCP

LP gas:

Minimum pressure: 11" WCP

Maximum pressure: 14" WCP

Contact local gas supplier if you are not sure about the inlet pressure.

†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

7

Image 7
Contents Table des matières Your safety and the safety of others are very important Range SafetyParts supplied Installation RequirementsTools and Parts Tools neededMobile home installations require Product DimensionsMobile Home Additional Installation Requirements Cabinet DimensionsElectrical Connection Electrical Requirements U.S.A. OnlyIf connecting to a 3-wire system If connecting to a 4-wire systemElectrical Requirements Canada Only Gas Pressure Regulator Gas Supply RequirementsType of Gas Gas Supply LineUnpack Range Installation InstructionsAdjust Leveling Legs Install Anti-Tip BracketFloor Mounting Wall Mounting Power Supply CordDirect Wire Electrical Connection U.S.A. OnlyStyle 2 Direct wire strain relief Style 1 Power supply cord strain reliefWire connection Power Supply Cord Wire Connection Direct Wire Wire Awg Torque Bare Wire Torque SpecificationsTypical flexible connection Make Gas ConnectionLevel Range Verify Anti-Tip Bracket Is Installed EngagedComplete connection Electronic Ignition System Complete InstallationLP Gas Conversion GAS ConversionsTo Convert Gas Pressure Regulator To Convert Surface Burners LP Gas Orifice Spud Chart Burner Rating Color NumberNatural Gas Conversion Natural Gas Orifice Spud Chart Burner Rating Color Number For power supply cord-connected rangesMoving the Range For direct-wired ranges Votre sécurité et celle des autres est très importante Sécurité DE LA CuisinièreOutils nécessaires Exigences D’INSTALLATIONOutils et composants Pièces fourniesUtilisation d’un cordon d’alimentation électrique Exigences demplacementDimensions du produit Pièces nécessairesSpécifications électriques Dimensions du placardType de gaz Spécifications de l’alimentation en gazCanalisation de gaz Débit thermique des brûleurs Instructions DinstallationDéballage de la cuisinière Détendeur de gazRéglage des pieds de nivellement Installation de la bride antibasculementMontage au plancher Montage au mur Raccordement typique par raccord flexible Raccordement au gazTerminer le raccordement Allumage initial et réglages des flammes Brûleurs de surface à commande tactile sur certains modèlesRéglage de laplomb de la cuisinière Système dallumage électroniqueRéglage des brûleurs standard Achever linstallationSi vous avez besoin d’assistance ou de service Réglage de la taille des flammesConversion pour lalimentation au gaz Propane Conversions DE GAZConversion des brûleurs de surface Conversion du détendeurConversion pour lalimentation au gaz Naturel Déplacement de la cuisinière Page Page Page Page W10526086A