Frymaster KSCF18G Conversion of Units, Restraining the Fryer, Pressure, Heat Input, Temperature

Page 12

KSCF18G COOL ZONE SERIES GAS FRYERS

CHAPTER 2: IMPORTANT INFORMATION

2.8 Conversion of Units

Pressure:

1 mbar = 10.2 mm water column (mm W.C.) = 0.4 Inch W.C. 20 mbar = 204 mm W.C. = 8 Inch W.C.

1 inch W.C. = 25.4 mm W.C. = 2.5 mbar

Heat Input:

1 kW = 3410 BTU/hr

100 BTU/hr = 0.0293 kW

Temperature:

0º Celsius = 32º Fahrenheit

Temperature in degrees Celsius = (Temperature in degrees Fahrenheit (F) – 32) x 0.555 100° Celsius = (212º Fahrenheit – 32) x 0.555

2.9 Restraining the Fryer

DANGER

No structural material on the fryer should be altered or removed to accommodate placement of the fryer under a hood. Questions? Call the Frymaster Dean Service Hotline at 1-800-551-8633.

1.Once the fryer has been positioned at the frying station, use a carpenter’s level placed across the top of the frypot to verify that the unit is level, both side-to-side and front-to-back.

To level fryers equipped with legs, the bottom of the legs can be screwed out up to one inch for leveling. Legs should also be adjusted so that the fryer(s) are at the proper height in the frying station.

For fryers equipped with casters, there are no built-in leveling devices. The floor where the fryers are installed must be level.

2.With the fryer level in its final position, install the restraints provided with the unit to limit its movement so that it does not depend on or transmit stress to the electrical conduits/connections or the gas supply line. Install the restraints in accordance with the provided instructions (see illustration on the next page). If disconnected for service or other reasons, the restraints must be reconnected before the fryer is used.

DANGER

Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to the electrical conduit. A restraint kit is provided with the fryer. If the restraint kit is missing contact your local Frymaster Factory Authorized Service Center (FASC) for part number 826-0900.

2-5

Image 12
Contents Gas Fryers KSCF18G Cool Zone Page Page KSCF18G Cool Zone Gas Fryers Applicability and Validity After PurchaseOrdering Parts Service Information Safety InformationComputer Information Safety Information Service Personnel Receiving and Unpacking Equipment GeneralIf your equipment arrives damaged Pre-Installation Principles of OperationRating Plate Australian installations must meet ANSI/NFPA #70Equipment Installed at High Altitudes Air Supply and VentilationTemperature Conversion of UnitsRestraining the Fryer PressureRestraining the Fryer Installing the Fryer Leg and Caster InstallationGeneral Installation Leveling the FryerInstalling Optional Swivel Casters Legs OnlyRigid Casters Only Gas Connections Countries Supply Pressures Appliance Gas mbar CategoriesSupply Line Specifications Rigid Connections Manual Shut-off ValveRegulating Gas Pressure Flexible Couplings, Connectors and Casters Adjustments/Adaptation To Different Gases Gas InputsGas Conversion Procedures Adjustments for different gases are as followsNon-CE Gas Valve Safety Switches Electrical ConnectionsFryer with KFC-1 Computer Microswitch is located on the red handle at the drain valve Drain valve handle red Oil return handle Yellow label Initial Cleaning Before Startup Final PreparationDrop Start-Up Procedures Pilot lighting procedures Standing PilotGeneral Use Pilot lighting procedure Electronic Ignition FilteringSee for detailed filtration procedures ClosingFilter Preparation Filter Powder Filter PaperFilter Preparation Filter Preparation Filter Preparation Filter Operations Removing support grid from frypot prior to draining Yellow Label Filter Operations Daily WeeklyPeriodic/Annual Built-in FiltrationPeriodic/ Annual Stainless SteelKSCF18G Cool Zone Series GAS Fryers Troubleshooting IntroductionFryer Troubleshooting PressedCont Remains after closing drain Main burner malfunctions Filtration System Troubleshooting Pump wont StartWiring Diagrams Normally Open Float Switch Left 3 CE, Normally Open Float Switch Right 4 CE, Normally Open Float Switch Left Fast Ready 218G KSCF218GP00001 Fast Ready 218G KSCF218GP00001, KSCF218GN00007 Thermatron, 230V CE Constant Pilot, Fast Ready 218G Constant Pilot with KFC-1, 218G Oil Return, 218G/318G with Vent Solenoids 11 CE, Single Oil Return, Single KSCF18G Cool Zone Series GAS Fryers Troubleshooting Cabinetry and Related Components Component Accessories Component Box, Computers, and Related Components See Page 8-10 for High-Limit Thermostats Holder, Buss Fuse Drain Valve, Oil Return, and Related Components Component Drain System Filter Pan and Related Components Filter Pan Assembly Other ComponentsFrypot and Related Components Gas Valves, Pilot Assemblies, and Related Components Trailing Pilot Assembly Rear Gas Manifold ComponentsPiezo Ignitor Components Over-the-Top Oil Return and Related Components 106-2983 Oil Return Assembly Cabinetry and Related Components Heat Shield, Flue Accessories Component Box, Computers, and Related Components See Page 9-10 for High-Limit Thermostats Holder, Buss Fuse Oil Return Handle Assembly 106-2214 Oil Return Assembly 106-0979 Oil Return Bracket Assembly106-2215 Oil Suction Components Filter Pan and Related Components Filter Components Filter Components non-CE Export823-4884SP CE Gas Valves Component Over-the-Top Oil Return and Related Components 106-3347 Oil Return Assembly Service Hotline