Frymaster KSCF18G manual Electrical Connections, Safety Switches, Fryer with KFC-1 Computer

Page 24

KSCF18G COOL ZONE SERIES GAS FRYERS

CHAPTER 3: INSTALLATION INSTRUCTIONS

3.8 Electrical Connections

DANGER

This fryer is equipped with a three-prong (grounding) plug for protection against electrical shock and must be plugged directly into a properly grounded, three-prong receptacle. DO NOT CUT, REMOVE, OR OTHERWISE BYPASS THE GROUNDING PRONG ON THIS PLUG!

DANGER

This appliance requires electrical power for operation. Place the gas valve in the OFF position in case of a prolonged power outage. Do not attempt to operate this appliance during a power outage.

Refer to the rating plate and wiring diagram located inside the front door. The diagram can also be found in Section 7.4. The fryer is equipped with a 120VAC/60Hz system for USA/Canada/Mexico operations or a CE-approved 230VAC/50Hz single-phase system for CE/International installations. All electrically operated appliances must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code (ANSI/NFPA 70), the Canadian Electrical Code (CSA C22.2), or the appropriate CE community standards. Do not cut or remove the ground prong from the power cord plug. Do not attempt to use this appliance in a power outage.

3.9 Safety Switches

A.Fryer with KFC-1 Computer

This fryer/filter system is equipped with a drain valve safety switch and a frypot float-switch on each of the two-batteried fryers. Drain-valve safety switches de-energize the control circuit during the filter process, thus providing an additional safety feature. Always leave the computer ON when filtering.

The KFC-1 computer monitors cooking operations. The computer logs the number of cook sequences and locks out the cook cycle after a preset number is reached. The drain-valve must be opened, the oil must be filtered, and the drain-valve closed before the KFC-1 computer will allow a cook cycle. After filtering, always allow the frypot to refill with oil and heat to setpoint before engaging a cook cycle.

See the accompanying KFC-1 SMS Cooking Computer User Manual for more detailed information.

3-11

Image 24
Contents Gas Fryers KSCF18G Cool Zone Page Page KSCF18G Cool Zone Gas Fryers Applicability and Validity After PurchaseOrdering Parts Service Information Safety InformationComputer Information Safety Information Service Personnel Receiving and Unpacking Equipment GeneralIf your equipment arrives damaged Pre-Installation Principles of OperationRating Plate Australian installations must meet ANSI/NFPA #70Equipment Installed at High Altitudes Air Supply and VentilationTemperature Conversion of UnitsRestraining the Fryer PressureRestraining the Fryer Installing the Fryer Leg and Caster InstallationGeneral Installation Leveling the FryerInstalling Optional Swivel Casters Legs OnlyRigid Casters Only Gas Connections Countries Supply Pressures Appliance Gas mbar CategoriesSupply Line Specifications Rigid Connections Manual Shut-off ValveRegulating Gas Pressure Flexible Couplings, Connectors and Casters Adjustments/Adaptation To Different Gases Gas InputsGas Conversion Procedures Adjustments for different gases are as followsNon-CE Gas Valve Safety Switches Electrical ConnectionsFryer with KFC-1 Computer Microswitch is located on the red handle at the drain valve Drain valve handle red Oil return handle Yellow label Initial Cleaning Before Startup Final PreparationDrop Start-Up Procedures Pilot lighting procedures Standing PilotGeneral Use Pilot lighting procedure Electronic Ignition FilteringSee for detailed filtration procedures ClosingFilter Preparation Filter Powder Filter PaperFilter Preparation Filter Preparation Filter Preparation Filter Operations Removing support grid from frypot prior to draining Yellow Label Filter Operations Daily WeeklyPeriodic/Annual Built-in FiltrationPeriodic/ Annual Stainless SteelKSCF18G Cool Zone Series GAS Fryers Troubleshooting IntroductionFryer Troubleshooting PressedCont Remains after closing drain Main burner malfunctions Filtration System Troubleshooting Pump wont StartWiring Diagrams Normally Open Float Switch Left 3 CE, Normally Open Float Switch Right 4 CE, Normally Open Float Switch Left Fast Ready 218G KSCF218GP00001 Fast Ready 218G KSCF218GP00001, KSCF218GN00007 Thermatron, 230V CE Constant Pilot, Fast Ready 218G Constant Pilot with KFC-1, 218G Oil Return, 218G/318G with Vent Solenoids 11 CE, Single Oil Return, Single KSCF18G Cool Zone Series GAS Fryers Troubleshooting Cabinetry and Related Components Component Accessories Component Box, Computers, and Related Components See Page 8-10 for High-Limit Thermostats Holder, Buss Fuse Drain Valve, Oil Return, and Related Components Component Drain System Filter Pan and Related Components Filter Pan Assembly Other ComponentsFrypot and Related Components Gas Valves, Pilot Assemblies, and Related Components Trailing Pilot Assembly Rear Gas Manifold ComponentsPiezo Ignitor Components Over-the-Top Oil Return and Related Components 106-2983 Oil Return Assembly Cabinetry and Related Components Heat Shield, Flue Accessories Component Box, Computers, and Related Components See Page 9-10 for High-Limit Thermostats Holder, Buss Fuse Oil Return Handle Assembly 106-2214 Oil Return Assembly 106-0979 Oil Return Bracket Assembly106-2215 Oil Suction Components Filter Pan and Related Components Filter Components Filter Components non-CE Export823-4884SP CE Gas Valves Component Over-the-Top Oil Return and Related Components 106-3347 Oil Return Assembly Service Hotline