Frymaster KSCF18G manual

Page 2

Please read all sections of this manual and retain for future reference.

NOTICE

This appliance is intended for professional use only and is to be operated by qualified personnel only. A Frymaster and Dean Factory Authorized Service Center (FASC) or other qualified professional should perform installation, maintenance, and repairs. Installation, maintenance, or repairs by unqualified personnel may void the manufacturer’s warranty. See Chapter 1 of this manual for definitions of qualified personnel.

NOTICE

IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER/DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER/DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.

NOTICE

This equipment must be installed in accordance with the appropriate national and local codes of

the country and/or region in which the appliance is installed.

NOTICE

Drawings and photos used in this manual are intended to illustrate operational, cleaning and technical procedures and may not conform to onsite management operational procedures.

NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS

U.S.

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. While this device is a verified Class A device, it has been shown to meet Class B limits.

Canada

This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set

out by the ICES-003 standard of the Canadian Department of Communications.

Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B prescrites dans la norme NMB-003 edictee par le Ministre des Communications du Canada.

DANGER

Improper installation, adjustment, maintenance or service, and unauthorized alterations or

modifications can cause property damage, injury, or death. Read the installation, operating and service instructions thoroughly before installing or servicing this equipment. Only qualified service personnel may convert this appliance to use a gas other than that for which it was originally configured. See Chapter 1 of this manual for definition of qualified service personnel.

Image 2
Contents Gas Fryers KSCF18G Cool Zone Page Page KSCF18G Cool Zone Gas Fryers Ordering Parts Applicability and ValidityAfter Purchase Computer Information Service InformationSafety Information Safety Information Service Personnel If your equipment arrives damaged Receiving and Unpacking EquipmentGeneral Rating Plate Pre-InstallationPrinciples of Operation Australian installations must meet ANSI/NFPA #70Equipment Installed at High Altitudes Air Supply and VentilationRestraining the Fryer TemperatureConversion of Units PressureRestraining the Fryer General Installing the FryerLeg and Caster Installation Installation Leveling the FryerRigid Casters Only Installing Optional Swivel CastersLegs Only Gas Connections Countries Supply Pressures Appliance Gas mbar CategoriesSupply Line Specifications Regulating Gas Pressure Rigid ConnectionsManual Shut-off Valve Flexible Couplings, Connectors and Casters Adjustments/Adaptation To Different Gases Gas InputsGas Conversion Procedures Adjustments for different gases are as followsNon-CE Gas Valve Fryer with KFC-1 Computer Safety SwitchesElectrical Connections Microswitch is located on the red handle at the drain valve Drain valve handle red Oil return handle Yellow label Initial Cleaning Before Startup Final PreparationDrop General Use Start-Up ProceduresPilot lighting procedures Standing Pilot Pilot lighting procedure Electronic Ignition FilteringSee for detailed filtration procedures ClosingFilter Preparation Filter Powder Filter PaperFilter Preparation Filter Preparation Filter Preparation Filter Operations Removing support grid from frypot prior to draining Yellow Label Filter Operations Daily WeeklyPeriodic/Annual Built-in FiltrationPeriodic/ Annual Stainless SteelKSCF18G Cool Zone Series GAS Fryers Troubleshooting IntroductionFryer Troubleshooting PressedCont Remains after closing drain Main burner malfunctions Filtration System Troubleshooting Pump wont StartWiring Diagrams Normally Open Float Switch Left 3 CE, Normally Open Float Switch Right 4 CE, Normally Open Float Switch Left Fast Ready 218G KSCF218GP00001 Fast Ready 218G KSCF218GP00001, KSCF218GN00007 Thermatron, 230V CE Constant Pilot, Fast Ready 218G Constant Pilot with KFC-1, 218G Oil Return, 218G/318G with Vent Solenoids 11 CE, Single Oil Return, Single KSCF18G Cool Zone Series GAS Fryers Troubleshooting Cabinetry and Related Components Component Accessories Component Box, Computers, and Related Components See Page 8-10 for High-Limit Thermostats Holder, Buss Fuse Drain Valve, Oil Return, and Related Components Component Drain System Filter Pan and Related Components Filter Pan Assembly Other ComponentsFrypot and Related Components Gas Valves, Pilot Assemblies, and Related Components Piezo Ignitor Components Trailing Pilot AssemblyRear Gas Manifold Components Over-the-Top Oil Return and Related Components 106-2983 Oil Return Assembly Cabinetry and Related Components Heat Shield, Flue Accessories Component Box, Computers, and Related Components See Page 9-10 for High-Limit Thermostats Holder, Buss Fuse Oil Return Handle Assembly 106-2215 Oil Suction Components 106-2214 Oil Return Assembly106-0979 Oil Return Bracket Assembly Filter Pan and Related Components Filter Components Filter Components non-CE Export823-4884SP CE Gas Valves Component Over-the-Top Oil Return and Related Components 106-3347 Oil Return Assembly Service Hotline