Frymaster KSCF18G manual Oil Return Assembly

Page 90

KSCF18G COOL ZONE SERIES GAS FRYERS

CHAPTER 9: PARTS LIST: SINGLE UNITS (118G)

9.8 Over-the-Top Oil Return and Related Components (cont.)

ITEM

PART #

COMPONENT

A

106-3347

Oil Return Assembly

1810-0697 Disconnect, Male

2813-0003 Tee, ½" x ½" x ½", BM

3813-0022 Nipple, ½" x Close NPT, BM

4813-0062 Elbow, ½", BM, 90°

5813-0173 Union, ½" NPT, BM

6813-0247 Nipple, ½" x 3.50 NPT, BM

7813-0298 Nipple, ½" x 2.00 NPT, BM

8813-0463 Plug, ½" Counter Sink

9813-0608 Coupling, ½" NPT, Full, BM

10816-0596 O-ring, .070 x .750

11823-3754 Manifold, Suction

B

106-5230

3-Way Oil Return Valve Assembly

12

106-5229

Support, Oil Return Valve

13

210-9643

Spring Clip

14210-9915 Cover, Microswitch

15210-9916 Support, Microswitch Mount

16807-2104 Switch, CE Microroller Lever

17809-0045 Nut, Cap, 10-32 Hex

18

809-0056

Nut, 516-18 Hex

19809-0117 Screw, 10-32 x ⅜", Slotted Truss Head

20809-0237 Nut, 4-40 Keps Hex with Extension Teeth

21809-0256 Nut, 10-32 Keps Hex

22809-0354 Screw, 4-40 x ¾" Round Head

23809-0942 Washer, 516" Belleville, 18-8, Stainless Steel

24810-1003 180° 3-Way Ball Valve

25816-0220 Insulation, Switch

26823-5362 Handle, 3-Way Valve, Over-the-Top

*810-2700 Nipple, Quick Disconnect, Snaptite

*813-0780 Bushing, Hex ½" x ⅜" NPT, BM

*810-2127 Drain Valve, 1 ½", Full Port

*Not illustrated.

9-14

Image 90
Contents Gas Fryers KSCF18G Cool Zone Page Page KSCF18G Cool Zone Gas Fryers Applicability and Validity After PurchaseOrdering Parts Service Information Safety InformationComputer Information Safety Information Service Personnel Receiving and Unpacking Equipment GeneralIf your equipment arrives damaged Pre-Installation Principles of OperationRating Plate Australian installations must meet ANSI/NFPA #70Equipment Installed at High Altitudes Air Supply and VentilationRestraining the Fryer TemperatureConversion of Units PressureRestraining the Fryer Installing the Fryer Leg and Caster InstallationGeneral Installation Leveling the FryerInstalling Optional Swivel Casters Legs OnlyRigid Casters Only Gas Connections Countries Supply Pressures Appliance Gas mbar CategoriesSupply Line Specifications Rigid Connections Manual Shut-off ValveRegulating Gas Pressure Flexible Couplings, Connectors and Casters Adjustments/Adaptation To Different Gases Gas InputsGas Conversion Procedures Adjustments for different gases are as followsNon-CE Gas Valve Safety Switches Electrical ConnectionsFryer with KFC-1 Computer Microswitch is located on the red handle at the drain valve Drain valve handle red Oil return handle Yellow label Initial Cleaning Before Startup Final PreparationDrop Start-Up Procedures Pilot lighting procedures Standing PilotGeneral Use Pilot lighting procedure Electronic Ignition FilteringSee for detailed filtration procedures ClosingFilter Preparation Filter Powder Filter PaperFilter Preparation Filter Preparation Filter Preparation Filter Operations Removing support grid from frypot prior to draining Yellow Label Filter Operations Daily WeeklyPeriodic/Annual Built-in FiltrationPeriodic/ Annual Stainless SteelKSCF18G Cool Zone Series GAS Fryers Troubleshooting IntroductionFryer Troubleshooting PressedCont Remains after closing drain Main burner malfunctions Filtration System Troubleshooting Pump wont StartWiring Diagrams Normally Open Float Switch Left 3 CE, Normally Open Float Switch Right 4 CE, Normally Open Float Switch Left Fast Ready 218G KSCF218GP00001 Fast Ready 218G KSCF218GP00001, KSCF218GN00007 Thermatron, 230V CE Constant Pilot, Fast Ready 218G Constant Pilot with KFC-1, 218G Oil Return, 218G/318G with Vent Solenoids 11 CE, Single Oil Return, Single KSCF18G Cool Zone Series GAS Fryers Troubleshooting Cabinetry and Related Components Component Accessories Component Box, Computers, and Related Components See Page 8-10 for High-Limit Thermostats Holder, Buss Fuse Drain Valve, Oil Return, and Related Components Component Drain System Filter Pan and Related Components Filter Pan Assembly Other ComponentsFrypot and Related Components Gas Valves, Pilot Assemblies, and Related Components Trailing Pilot Assembly Rear Gas Manifold ComponentsPiezo Ignitor Components Over-the-Top Oil Return and Related Components 106-2983 Oil Return Assembly Cabinetry and Related Components Heat Shield, Flue Accessories Component Box, Computers, and Related Components See Page 9-10 for High-Limit Thermostats Holder, Buss Fuse Oil Return Handle Assembly 106-2214 Oil Return Assembly 106-0979 Oil Return Bracket Assembly106-2215 Oil Suction Components Filter Pan and Related Components Filter Components Filter Components non-CE Export823-4884SP CE Gas Valves Component Over-the-Top Oil Return and Related Components 106-3347 Oil Return Assembly Service Hotline