Frymaster KSCF18G manual Periodic/ Annual, Stainless Steel

Page 42

KSCF18G COOL ZONE SERIES GAS FRYERS

CHAPTER 6: PREVENTATIVE MAINTENANCE

6.3 Periodic/ Annual (cont.)

Check filtration system integrity as follows:

With the filter pan empty, place each oil return handle in the OPEN position, one at a time. Using rear flush oil return, verify that the pump activates and that bubbles appear in the oil of the associated frypot. Using over-the-top oil return, verify that the pump activates and that the faucet sputters.

Close all oil return valves (i.e., place all oil return handles in the CLOSED position). Verify proper functioning of each oil return valve by activating the filter pump using the lever on one of the oil return handle microswitches. No air bubbles should be visible in any frypot and the over-the-top faucet should not sputter.

Verify that the filter pan is properly prepared for filtering, then drain a frypot of oil heated to 350°F (177°C) into the filter pan and close the frypot drain valve. Place the oil return handle in the OPEN position. Allow all oil to return to the frypot. The frypot should refill in no more than 2 minutes and 30 seconds. Move the oil return handle to the CLOSED position when the oil return lines are clear of oil (indicated by bubbles in the oil in the frypot or sputtering in the over-the-top faucet).

To ensure good fryer health and a safe environment, the fryer should be checked and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance program.

6.4 Stainless Steel

All stainless steel fryer outer parts should be wiped regularly with hot, soapy water during the day and with a liquid cleaner designed for this material at the end of each day.

Do not use steel wool, abrasive cloths, cleansers, or powders!

Do not use a metal knife, spatula, or any other metal tool to scrape stainless steel! Scratches are almost impossible to remove.

If it is necessary to scrape the stainless steel to remove any encrusted materials, soak the area to loosen the material and use a wood or nylon scraper only.

6-3

Image 42
Contents Gas Fryers KSCF18G Cool Zone Page Page KSCF18G Cool Zone Gas Fryers Applicability and Validity After PurchaseOrdering Parts Service Information Safety InformationComputer Information Safety Information Service Personnel Receiving and Unpacking Equipment GeneralIf your equipment arrives damaged Pre-Installation Principles of OperationRating Plate Australian installations must meet ANSI/NFPA #70Equipment Installed at High Altitudes Air Supply and VentilationRestraining the Fryer TemperatureConversion of Units PressureRestraining the Fryer Installing the Fryer Leg and Caster InstallationGeneral Installation Leveling the FryerInstalling Optional Swivel Casters Legs OnlyRigid Casters Only Gas Connections Countries Supply Pressures Appliance Gas mbar CategoriesSupply Line Specifications Rigid Connections Manual Shut-off ValveRegulating Gas Pressure Flexible Couplings, Connectors and Casters Adjustments/Adaptation To Different Gases Gas InputsGas Conversion Procedures Adjustments for different gases are as followsNon-CE Gas Valve Safety Switches Electrical ConnectionsFryer with KFC-1 Computer Microswitch is located on the red handle at the drain valve Drain valve handle red Oil return handle Yellow label Initial Cleaning Before Startup Final PreparationDrop Start-Up Procedures Pilot lighting procedures Standing PilotGeneral Use Pilot lighting procedure Electronic Ignition FilteringSee for detailed filtration procedures ClosingFilter Preparation Filter Powder Filter PaperFilter Preparation Filter Preparation Filter Preparation Filter Operations Removing support grid from frypot prior to draining Yellow Label Filter Operations Daily WeeklyPeriodic/Annual Built-in FiltrationPeriodic/ Annual Stainless SteelKSCF18G Cool Zone Series GAS Fryers Troubleshooting IntroductionFryer Troubleshooting PressedCont Remains after closing drain Main burner malfunctions Filtration System Troubleshooting Pump wont StartWiring Diagrams Normally Open Float Switch Left 3 CE, Normally Open Float Switch Right 4 CE, Normally Open Float Switch Left Fast Ready 218G KSCF218GP00001 Fast Ready 218G KSCF218GP00001, KSCF218GN00007 Thermatron, 230V CE Constant Pilot, Fast Ready 218G Constant Pilot with KFC-1, 218G Oil Return, 218G/318G with Vent Solenoids 11 CE, Single Oil Return, Single KSCF18G Cool Zone Series GAS Fryers Troubleshooting Cabinetry and Related Components Component Accessories Component Box, Computers, and Related Components See Page 8-10 for High-Limit Thermostats Holder, Buss Fuse Drain Valve, Oil Return, and Related Components Component Drain System Filter Pan and Related Components Filter Pan Assembly Other ComponentsFrypot and Related Components Gas Valves, Pilot Assemblies, and Related Components Trailing Pilot Assembly Rear Gas Manifold ComponentsPiezo Ignitor Components Over-the-Top Oil Return and Related Components 106-2983 Oil Return Assembly Cabinetry and Related Components Heat Shield, Flue Accessories Component Box, Computers, and Related Components See Page 9-10 for High-Limit Thermostats Holder, Buss Fuse Oil Return Handle Assembly 106-2214 Oil Return Assembly 106-0979 Oil Return Bracket Assembly106-2215 Oil Suction Components Filter Pan and Related Components Filter Components Filter Components non-CE Export823-4884SP CE Gas Valves Component Over-the-Top Oil Return and Related Components 106-3347 Oil Return Assembly Service Hotline