Bunn SNG0033000 manual Brew OZ Setting or Adjusting Brew VOL- Umes, Batches DONE? No YES

Page 18

PROGRAMMING THE BREWER (cont.)

BREW OZ (SETTING OR ADJUSTING BREW VOL- UMES)

This function allows adjustment of the brew vol- umes for each batch. The indicator signifies volume in ounces per batch.

Procedure for modifying recipes - brew ounces: Range: 10.0 oz to 400 oz for all three batch sizes

1.Press and hold upper right hidden switch (®) until the display reads UNITS. Release the switch, then press and release switch until the display reads

REVIEW RECIPES.

2.Press YES to proceed. The display should now read:

NO NAME, along with MODIFY, SHOW and NEXT (SINGLE brewers)

NO-NAME LEFT, along with MODIFY, SHOW and NEXT (DUAL brewers).

3.Press and release NEXT to advance to the desired coffee name to be modified.

4.Press and release MODIFY. The display should read BREW OZ: and a batch light will be blinking. Press and release the batch size to be modified.

5.Using (-)and (+), set the amount of brew water, in ounces, to be dispensed over the grounds for that particular batch size.

6.When finished, press another batch size and repeat step 5 for that size for each batch size to be modi- fied. Continue setting all batch sizes.

7.When finished setting all batch sizes, press and release DONE. The display should read 3 BATCH

SIZES DONE?

8.If the three batch sizes are not correct, press and release NO to return to the BREW OUNCES setup screen and repeat steps 5, 6 and 7.

9.If the three batch sizes are correct, press YES. This will advance to the % BYPASS function. Another alternative is to press and release the ON/OFF switch (either on DUAL brewers) to exit the BREW OZ setup and return to the MAIN SCREEN.

REVIEW RECIPES?

NOYES

EXIT TO

NEXT FUNCTION

SCREENSINGLE BREWERS

NO-NAME

MODIFY SHOW NEXT

DUAL

BREWERS

NO-NAME LEFT

MODIFY SHOW NEXT

BREW OZ. XX.X (-) DONE (+)

3 BATCHES DONE?

NO YES

%BYPASSS XX.X (-) DONE (+)

SEE MODIFYING

BYPASS PERCENTAGES

ON THE FOLLOWING PAGE

OR PRESS AND RELEASE

ON/OFF SWITCH TO EXIT THE

BREW OZ: SETUP AND RETURN

TO THE MAIN SCREEN

ADVANCES TO ALL OTHER

COFFEE NAMES PROGRAMMED

IN THE BREWER"S MEMORY

(COFFEE NAME)

MODIFY SHOW NEXT

WHEN THE LAST COFFEE

NAME IN BREWER'S MEMORY

IS DISPLAYED, PRESSING NEXT WILL EXIT AND THE DISPLAY WILL THEN READ:

THAT WAS THE

LAST RECIPE

Page 18

41341 080108

 

Image 18
Contents Dual SH DBC BUNN-O-MATIC Commercial Product Warranty Introduction Glossary Programming Switches ProgrammingOutputs Programming Lockout Switch mounted on main control boardScreen Main ScreenRecipe Programing Methods Using a Smart Funnel and a G9-2T DBC or MHG GrinderNot using a Smart Funnel and/or a G9-2T DBC or MHG Grinder RecipesLevel Continue toProgram Flow Diagram Program Flow Diagram Units Setting Units of Measure Procedure for modifying units of measureEnable Energysavr NEW Recipe ?Procedure for Setting the Recipe SET NEW RecipeSET NEW Recipe Sizes DONE? Procedure to program the coffee name SET NEW RecipesReview RECIPES? No YES Review Recipes Review RECIPES/MODIFY RECIPES/SET UP no Name Coffee FavorsProcedure for reviewing recipes WAS the Last RecipeBrew OZ Setting or Adjusting Brew VOL- Umes Batches DONE? No YESBypass SET Pulse Brew Modifying pulse brewSET Pulse Brew SET Pulse Brew Easy Pulse Setup SET Pulse Brew Enter Times TIMES?DONE? SET Preinfusion Batches DONE?Procedure to modify drip times Setup CompleteDrip Time now displayed on non funnel lock units as well Assign Recipes Procedure to copy settingsReads Copy Settings OnlyAre YOU SURE? Enable ADS?YOU SURE? SET TempSET Ready Procedure to set ready temperatureSET Temp Refill Range 20 toProcedure to adjust the flow rate setting Spray OZ/M Single BrewersSpray OZ/M Dual Brewers Bypass OZ/M Single Brewers Bypass OZ/M Dual BrewersProcedures to calibrate the sprayhead flow rate Calibrate FlowCalibrate Flow ? Procedures to calibrate the bypass flow rate Brate Bypass .. Press Brew to StartProcedures to view/reset the brew counters Brew CountersServer Detect Funnel DetectServer not in Place Service Tools Programming the Brewer Nothing Pressed SERVERS?Factory Defaults Procedure to set factory defaultsTest FREQUENCY?